Company Name: Yueqing Huadong Instrument and Meter Factory
Specialist Area: Temperature Sensors
Operating Type: Manufacturer
Employees: 50–100
Established: 1986
Website: china-h.com
Email: ben@china-h.com
Phone: +86-577-6231-1698
E-commerce: Alibaba Made-in-China
Location: Shifan Industrial Zone, Hongqiao, Yueqing, Zhejiang, China
Established in 1986, Yueqing Huadong Instrument and Meter Factory (HUADONG) is located in Shifan Industrial Zone, Hongqiao, Yueqing, Zhejiang, China. Its core products are industrial thermocouples and RTD temperature sensors, including sheathed probes, assembled probes, surface-temperature probes, multipoint probes and temperature assemblies with integrated transmitters. It also supplies sheathed temperature-sensing cables, electric heaters for hot runner systems, sensing elements and mounting accessories.
HUADONG offers a varied selection of probe structures, mounting and connection options. Common configurations include K, E, J and T thermocouples, Pt100 RTDs, direct leads, terminal heads, connectors, fixed threads, compression fittings and flanges. Its product ranges cover rubber and plastics machinery, hot runner systems, pipe-wall and bearing-surface measurement, furnaces and process equipment. Factory photographs show machining, probe assembly and material storage, providing an initial view of its manufacturing activities.
From a sourcing perspective, Hibelec considers HUADONG worth including on a quotation shortlist for thermocouples, Pt100 probes and temperature-sensing assemblies for industrial equipment. Selection and quotation requests should define application-specific requirements, including the thermocouple type or resistance element, accuracy class, operating temperature, protective-tube material and diameter, insertion length, mounting interface and wiring arrangement. Sample calibration results, dimensional tolerances, instrument compatibility, production lead times and after-sales arrangements should also inform the final purchasing specification.
Dual-element Pt100 sheathed RTD probes with direct nickel-plated leads, a spring-protected welded cold end and no fixed mounting. Select sheath material, diameter and immersion length.
Compact-terminal sheathed RTD probes offer Pt100, Cu50 or Cu100 elements with spring-protected connections. Choose a probe without fixed mounting or a fixed-thread version and its immersion length.
Handheld sheathed thermocouple probes combine a straight grip, spring-protected leads and a portable-meter connector. Select the large-grip or slim-grip version, sensor type and insertion length.
Assembled probes use ceramic-bead insulation and replaceable components. Select thermocouple or RTD elements, plastic or aluminum heads, protective tubes and a suitable mounting arrangement.
Fixed-mount probes place sheathed thermocouple or RTD elements inside protective tubes. Choose flange or threaded mounting, single or dual elements, spring-loaded inserts and aluminum or steel heads.
Sheathed probes use compact water-resistant heads and direct-contact sensing elements. Choose adjustable compression fittings, fixed process threads or no fixed mounting to suit installation.
Sheathed thermocouple probes offer K, E, J or T elements with direct leads, compact terminals or stainless steel hose protection. Choose fixed, adjustable or cap mounting and required probe length.
Miniature-connector thermocouple probes use thin sheathed elements with pressure-contact terminals and a clamping connection. Choose K or J sensing, sheath material, diameter and an insertion length.
Band-mounted thermocouples measure pipe surface temperature through an adjustable clamp. Thermocouple leads are welded to the band, which collects heat from the pipe without inserting a probe inside.
Bearing surface probes offer Pt100 RTD or K and E thermocouple elements in single or dual versions. The 23ZC RTD design follows surface movement, with adjustable depth and sealed installation.
Flue and air-duct thermocouples use a drilled protective tube, a reduced measuring tip and a spring-loaded sensing insert. The separate tube and insert support sensing-element replacement.
Welded-sleeve probes measure steam or water temperature with spring-loaded inserts and drilled tubes. Select the 14, 13, 01 or 62K construction for its temperature, pressure and flow limits.
Integrated probes combine a thermocouple or RTD with a head-mounted transmitter. A two-wire 4-20mA output supports remote temperature monitoring, with selectable sensing elements and local displays.
Multipoint sheathed probes measure temperature at different depths in towers, tanks and equipment. Select thermocouple or Pt100 configurations, sensing-point layout, probe length and mounting.
Wear-resistant thermocouples combine a protected measuring end with a manual shutoff valve. Choose K, E or J elements, single or dual sensors, mounting and protective-tube material for the process.
Knife-edge surface thermocouples attach to furnace walls or tubes with locating clips. Choose a shielded or unshielded blade, K, E, J or T sensing, single or dual elements and required total length.
Spring-loaded sheathed inserts seat against separate protective tubes. Choose thermocouple or RTD sensing, an aluminum flameproof head, threaded or flanged mounting and a suitable tube material.
Assembled thermocouple and RTD probes use a two-chamber aluminum flameproof head for replaceable measuring elements. Select K, E, Pt100 or Cu50 sensing, tube material, mounting and insertion length.
Stainless steel flameproof temperature probes offer flanged or threaded mounting, straight or stepped drilled protective tubes and single or dual inserts. Select element, head and process connection.
Wear-resistant temperature probes use stainless steel flameproof heads with internal insert seals. Choose coated or solid drilled alloy protection, single or dual sensing, mounts and dimensions.
WRSH-331 S-type thermocouples measure converter drying kiln temperature. Adjustable twin rings and a crossbar support a GH3030 outer tube with ceramic inner protection, with custom dimensions.
Flue thermocouple probes use GH3030 protective tubes and an anti-vibration design for blast furnace ducts. Choose R or J sensing, no fixed mounting or a compression thread, and a custom probe length.
Gas-purged thermocouples circulate nitrogen or argon between the insert and solid drilled outer tube. Choose K, S or R sensing, mounting, connection head and custom dimensions for furnace service.
WRRT-1000 R-type thermocouples combine a GH3030 outer tube, corundum inner tube and adjustable insulating bellows. They measure pipe or vacuum-vessel temperature with single or dual element options.
S and R thermocouples measure molten metals and alloys through double nonmetallic protection. A special quartz outer tube surrounds a corundum or quartz inner tube, with mounting and head choices.
WRSY S-type thermocouples measure blast furnace flue temperature with a GH3030 alloy tube and anti-vibration construction. Choose no fixed mount, thread or flange, and standard or custom dimensions.
Temperature probes place the sheathed insert directly in the measured medium. Select K, E, J, T, Pt100 or Pt1000 sensing, a polished stainless flameproof head, process connection and insertion.
16000 series assemblies place single or dual sheathed inserts inside flanged or solid drilled protective tubes. Choose K, E, J, T or Pt100 sensing, tube material, connection head and insertion.
L-shaped sheathed thermocouples combine a bent measuring end with PTFE-insulated compensation leads. Choose K or J sensing, junction form, sheath diameter and material, insertion and lead lengths.
400 series probes combine sheathed thermocouples, fiberglass-insulated compensation leads and a connector. Choose K, E, J or T sensing, junction and sheath material, with standard or custom lengths.
700 series thermocouples use direct-contact sheathed sensing with threaded connections. Choose K, E, J or T elements, a cast iron or aluminum head, or a standalone insert with compensation leads.
Direct-contact sheathed probes combine compact threaded connections with aluminum or stainless steel waterproof heads. Choose K, E, J, T, Pt100 or Pt1000 sensing and standard or custom insertion.
Flange-mounted temperature probes use a reinforced connecting tube and large cavity aluminum head. Direct-contact thermocouples or Pt100/Pt1000 RTDs serve food, dairy, beverage and process duties.
25121 J-type probes combine a 304SS sensing tube with PTFE-insulated compensation leads for catering temperature control. An insulated junction and bare-wire termination support installation.
5508 and 5508L probes combine compensation wire sensing with stainless steel tubes. Choose J-type insulated 5508 or K/J/T grounded 5508L, with separate lead, transition and termination arrangements.
A handheld temperature assembly combines a K-type thermocouple probe and digital display for nonferrous metal melts. The manufacturer lists a maximum temperature of 1255°C for this sensing design.
102A handheld probes measure stationary surfaces using a protected band sensing tip, straight grip and connector. Choose K or E elements, sheath material and standard or custom measuring lengths.
530 thermocouples use a right-angle joint, ceramic bead insulation and an aluminum waterproof head. K or E elements measure furnace, kiln or solution temperatures with replaceable parts.
WZP-805 Pt100 probes measure equipment steam temperature using a threaded sensing tip and spring-protected lead exit. Single or dual three-wire elements are available with standard or custom lengths.
031G pipe wall probes clamp a heat-transfer plate against the pipe without welding. K, E, J, T or Pt100 elements combine with a stainless clamp, aluminum head and custom sensing assembly dimensions.
Reduced-tip probes use a narrow sensing end, threaded mounting and a reinforced connection to a small aluminum head. K, E, J or T elements serve temperature measurement at confined equipment points.
Compact threaded RTDs offer a miniature terminal head for confined locations or direct three-wire leads for equipment sensing. Pt100, Pt500 and Pt1000 options depend on the selected construction.
191 thin sheathed thermocouples offer K, E or J sensing with insulated or grounded junctions. Stainless or resin cold ends provide different probe diameters and maximum connection temperatures.
Dual-element sheathed RTDs use direct leads and a silver-copper welded cold end with a buffer spring. Pt100, Cu50 or Cu100 elements offer different sensing ranges, diameters and current limits.
Screw-fixed thermocouples weld a sheathed element to a measuring ring for hot runner monitoring. K, E or J insulated junctions connect through compensation leads with standard or custom lengths.
Stud-type probes monitor hot runner manifolds with K, E or J thermocouples. Insulated or grounded junctions, KAPTON-type or fiberglass shielding and protective springs support equipment installation.
Cap-mounted thermocouples use a spherical tip and spring-adjusted height for rubber and plastic machinery. Choose K, E, J or T elements, insulated or grounded junctions and connector termination.