191 Series Thin Sheathed Thermocouples for Hot Runner Systems

Description

Thin probes with two cold-end constructions

The WRNK-191 family offers thin sheathed K, E or J thermocouples with insulated or grounded measuring junctions. Compensation leads use KAPTON-type or fiberglass shielding. The stamped stainless cold-end version measures objects, liquids and gases as well as hot runner systems. The molded high-temperature resin version is intended specifically for hot runner measurement.

Model referenceConstructionProbe diametersCold-end sizeMaximum connection temperatureTensile loadDielectric withstandLeakage current
WRNK-191Stamped stainless cold end1mm, 1.5mm, 1.6mm, 2mm or 3mm6mm diameter ×30mm200°CNot specified400V<0.5mA
Molded resin cold end1mm, 1.5mm or 1.6mm5mm diameter ×25mm300°C10kgf

The connection temperature limits apply to the cold-end joint and are separate from the sensing ranges.

Sheath material and sensing range

Model referenceCold-end versionElementsSheath materialDiameterRangeListed tolerance
WRNK-191Stamped stainless or resinK, E or J06Cr18Ni11Ti1mm0-400°C±2.5°C or ±0.75%t
1.5mm or 1.6mm0-600°C
Stamped stainless2mm
3mm0-800°C
Stamped stainless or resinK onlyGH30301mm0-500°C
1.5mm or 1.6mm0-800°C
Stamped stainless2mm or 3mm

GH3030 sheath construction is limited to K-type elements, as specified in the 191 family material note.

Lengths and lead terminations

Model referenceConstructionInsertionConnecting lead lengthCompensation leadTermination choices
WRNK-191Stamped stainless cold end200-3000mm500-3000mmStranded 0.5mm² or 0.2mm²Plug-in, crimped or bare wire
Molded resin cold endPlug-in

Other dimensions are available to suit the installation.