Gas-Purged Thermocouple Probes with Solid Drilled Tubes

Description

Inert-gas circulation around the sensing insert

A solid drilled outer tube provides a thick protective layer. Nitrogen or argon circulates between the thermocouple and outer tube to reduce the entry of reducing gases into the sensing element at high temperature. Choose an aluminum water-resistant head or a large dust-protective head.

Model familyElementOperating rangeAccuracy classGas inlet pressurePurge gasProtective tube
WRKT-□□□QK0-1100°CII0.1MPaNitrogen or argonGH3030
WRST-□□□QS0-1300°C
WRRT-□□□QR

Mounting and dimensions

Mount codeProcess mountingOuter diameterTotal and insertion lengths
0Cylindrical sleeve16-30mmUser-specified
1No fixed mounting
2Threaded connection; M27x2 or M33x2
4Fixed flange; flange specification selected by user

Single-element electrical entry is M20x1.5 for 10mm cable; dual-element entry is M24x1.5 for 16mm cable. Dual measuring elements and other dimensions are available.