These sheathed resistance temperature probes use compact pressure-contact terminals and a spring-protected cold end. Pt100 platinum and Cu50 or Cu100 copper sensing elements are available. The version without a fixed mounting device uses a hex-pressed cold-end connection; the fixed-thread version provides a threaded process connection.
| Sensor type | Element | Sheath material | Sheath diameter | Temperature range options | Accuracy | Maximum measuring current |
|---|---|---|---|---|---|---|
| WZPK Platinum RTD | Pt100 | 06Cr18Ni11Ti | 3mm | -200-250°C or -200-420°C | Class A or B | Class A: ≤2mA; Class B: ≤5mA |
| 4mm, 5mm, 6mm or 8mm | -200-420°C or 0-500°C | |||||
| 3YC-52 alloy | 0-650°C | |||||
| WZCK Copper RTD | Cu50 or Cu100 | 06Cr18Ni11Ti | 5mm, 6mm or 8mm | -50-150°C | ±(0.30+0.006t)°C | ≤5mA |
Choose the temperature range together with its material and diameter. Copper-element diameter choices are limited to 5mm, 6mm and 8mm in this range table. In its tolerance formula, t is the absolute temperature magnitude in °C.
| Sheath diameter | Immersion length | Lead length |
|---|---|---|
| 8mm | 100-2500mm | User specified |
| 6mm | 75-2000mm | |
| 5mm | 75-1500mm | |
| 4mm | 50-1000mm | |
| 3mm | 50-750mm |
| Configuration | Connection | Available thread | Thread length |
|---|---|---|---|
| No fixed mounting | Hex-pressed cold end | None | Not applicable |
| Fixed-thread mounting | Fixed process thread | NPT1/2, G1/2 or M20x1.5 | User specified |