These refinery thermocouples combine a wear-resistant measuring end with a manual shutoff valve. If wear causes leakage through the protective tube, the valve can be manually closed to interrupt the leakage path. Single or dual sheathed sensing elements and fixed-flange or fixed-thread mounting are available.
| Model | Element | Sheath material | Measuring range | Accuracy selections |
|---|---|---|---|---|
| WRNN-4G31 | K | 3YC-52 alloy | 0-1200°C | I or II, within the class range below |
| 06Cr18Ni11Ti | 0-850°C | |||
| WREN-4G31 | E | 0-600°C | ||
| WRFN-4G31 | J |
The valve dimensions are listed as (80+50)x180mm. Single-element electrical entries are M20x1.5 for 10mm cable; dual-element entries are M24x1.5 for 16mm cable.
| Sensor type | Element | Class I applicable range | Class I tolerance | Class II applicable range | Class II tolerance |
|---|---|---|---|---|---|
| Nickel-chromium / nickel-silicon | K | -40-1000°C | ±1.5°C or ±0.4%|t| | -40-1200°C | ±2.5°C or ±0.75%|t| |
| Nickel-chromium / copper-nickel | E | -40-800°C | -40-900°C | ||
| Iron / copper-nickel | J | -40-750°C | -40-750°C |
Use the model measuring range as the assembly limit, together with the selected accuracy class's applicable range. For example, the 1200°C K-alloy model extends beyond the listed Class I range.
| Head | Mounting | Mounting specification | Tube shape and diameter | Wear-layer length | Insertion length |
|---|---|---|---|---|---|
| Water-resistant | Fixed flange | Standard and specification selected for application | Straight: 20mm or 22mm, or specified | 300mm | 500mm, 600mm, 750mm, 1000mm, 1250mm or 1500mm, or specified |
| Tapered: 20mm or 25mm, or specified | |||||
| Fixed thread | Selected for application | Straight: 20mm or 22mm, or specified | |||
| Tapered: 20mm or 25mm, or specified |