Multipoint Sheathed Thermocouple and Pt100 Temperature Probes

Description

Temperature profiles at multiple depths

Multipoint sheathed probes measure temperature at selected depths in towers, reaction tanks and process equipment. Single-stem multipoint and multiple-probe multipoint thermocouple constructions are available. A related thermocouple and Pt100 construction provides 3-point, 6-point and 12-point diameter selections for fertilizer-industry towers and tanks.

Element and temperature range selection

Sensor typeElementSheath materialTemperature rangeAccuracy classConfiguration availability
Platinum-10% rhodium / platinumSGH30 alloy0-1200°CI or IIBoth multipoint constructions
Nickel-chromium / nickel-siliconK0-1100°C
06Cr18Ni11Ti0-800°C
Nickel-chromium / copper-nickelE0-700°C
Iron / copper-nickelJ0-600°C
Copper / copper-nickelT-200-300°C3-point, 6-point and 12-point construction
Platinum RTDPt100-200-500°CB

Single-stem and multiple-probe capacities

Thermocouple constructionMaximum measuring pointsMaximum length
Single-stem multipoint68m
Multiple-probe multipoint30150m

The multiple-probe construction can use sheathed elements as small as 0.5mm. Ordinary water-resistant, flameproof and stainless steel flameproof heads are available. Mounting options include no fixed device, M33x2 or M27x2 threads, a 70mm sliding flange or a fixed flange specified for the application.

Three, six and twelve measuring-point diameters

Measuring pointsSheath diameter options
33mm, 4mm, 5mm, 6mm or 8mm
63mm, 4mm, 5mm or 6mm
123mm

For the tower-and-tank construction, sheath diameters below 5mm can support specified depths exceeding 30m. The installation requires an outer protective tube supplied for the application; without it, use is limited to atmospheric-pressure, non-corrosive media. Two output connections are provided per measuring point and arranged by point sequence. A two-wire RTD output can use two terminal connections at one end and one at the other for a three-wire instrument connection.

Measuring junction and insulation

Insulated and grounded thermocouple junctions are available. Grounded junctions are not recommended for flameproof versions. Flameproof marking options include Ex d IIB T1-T5 and Ex d IIC T1-T6.

ParameterTower-and-tank multipoint specification
Thermocouple insulation at ambient temperature≥1000MΩ
Thermocouple insulation at high temperature≥5MΩ
Platinum RTD insulation at ambient temperature≥100MΩ
Flameproof thermocouple and RTD ingress protectionUp to IP65