UZ-600B combines a compact explosion-proof housing with a threaded process connection for liquids and gases compatible with 304 stainless steel. Gauge and absolute pressure versions are available. The instrument has no local LCD and provides a selected current, voltage or RS485 output.
| Parameter | UZ-600B |
|---|---|
| Range selections | ±200–800Pa; -100–900kPa; 1–100MPa |
| Pressure reference | Gauge or absolute |
| Accuracy options | ±0.2% or ±0.5% |
| Temperature | 0–60°C |
| Compatible media | Liquids and gases compatible with 304 stainless steel |
| Male process threads | G1/8, G1/4, G3/8, G1/2, G3/4, NPT1/4, NPT3/8, NPT1/2, M10×1, M12×1, M14×1.5 or M20×1.5; customization available |
| Output choices | Two-wire 4–20mA; three-wire 1–5V or 0–10VDC; four-wire RS485 |
| RS485 address range | 1–255 |
| 4–20mA supply | 10–30VDC |
| 0–10V supply | 12–30VDC |
| Electrical entry | M14×1 |
| Overload | 1.5× full scale standard; special versions available |
| Explosion-protection designation | Ex d IIC T6 Gb |
| Local LCD | None |
Specify the calibrated range, pressure reference, process thread and signal output. Negative-pressure selections apply to gauge measurement. Use the supply requirements for the ordered electrical configuration.