EP Polypropylene Vertical Float Level Switches

Description

Threaded polypropylene level switches

The EP series combines a polypropylene body and magnetic float with an internal reed switch. As the liquid level changes, the float moves along the stem and changes the electrical contact state. Single-float models provide one sensing point; double-float models support two level positions.

Reverse the float orientation to configure normally open or normally closed operation, then verify the actual state after assembly. The threaded mounting suits compact water tanks, appliance reservoirs, humidifiers and compatible industrial-liquid systems.

Electrical contact options

Parameter1A12A1
Operating and storage temperature−30–85°C−20–85°C
Contact power rating10W / 10VA20W for 100–265VAC loads; 10W for other loads
Maximum DC switching voltage200VDC200VDC
Maximum AC switching voltage140VAC265VAC RMS
Minimum breakdown voltage250VDC400VDC
Maximum DC switching current0.5A0.4A
Maximum AC switching current0.35A0.3A
Maximum carry current1.0A1.4A
Contact resistance≤0.1Ω≤0.1Ω
Insulation resistance≥10¹⁰Ω≥10¹⁰Ω
Typical contact capacitance0.2pF0.2pF

Observe switching voltage, current and power limits together. Carry-current and breakdown-voltage values are separate from switching ratings. For a 220VAC control circuit, select the 2A1 option and keep the receiving relay load within its rated limits.

Glass reed contact elements used in magnetic level switches
A magnetic float actuates the sealed reed contact.
Polypropylene annular float with internal magnet
The movable magnetic float provides the level-sensing action.

Compact single-float dimensions

All dimensions are in millimeters. L1, L2 and H1–H5 refer to the corresponding diagrams in the dimension attachment.

ModelL1L2H1H2H3H4Thread
EP2508186.7102536M8×1.25
EP32081971232417M8×1.25
EP350819712354.517M8×1.25
EP400824712404.522M8×1.25
EP43102471543522M8×1.25
EP451024813454.522M8×1.25

Extended single-float dimensions

ModelL1L2H1H2H3H4Thread
EP52102581552425M10×1.5
EP60102581560425M10×1.0
EP75102581575425M10×1.0
EP85102581585425M10×1.0
EP1001025815100425M10×1.0

Double-float dimensions

All models in this table use L1=24mm, H1=13.5mm, H3=6mm, H4=28mm and an M10×1.5 thread.

ModelH2H5
EP10010-2-5010050
EP12010-2-6112061
EP15010-2-8315083
EP20010-2-139200139
EP25010-2-188250188
EP30010-2-228300228
EP40010-2-310400310
EP50010-2-408500408

For an EP10010-2-48 request, confirm the required switching spacing and final drawing before ordering. Custom dimensions and configurations are available.

Installation and selection

EP float switch lead wires
Connect the passive reed contact to a circuit suited to the selected contact rating.

Choose the mounting thread, stem dimensions, number of floats and contact option for the application. Allow each float to move freely without rubbing against tank walls or deposits. Verify the NO/NC state and both switching points on a double-float assembly before service.

Use water, clean liquids or mildly corrosive media compatible with polypropylene. Check the actual temperature and chemical conditions, protect the cable and keep terminations dry. Use a suitably rated external relay or contactor for loads beyond the float contact’s capacity.