ELE-808B and ELE-809 use ultrasonic measurement for liquid levels and material levels. ELE-808B combines the electronics and sensing head in an integrated unit. ELE-809 uses a separate display/controller and probe, allowing the operator interface and measurement point to be installed separately.
Built-in temperature compensation supports measurement across the specified operating temperature range. Applications include wastewater tanks, settling and aeration basins, rivers and water-resource monitoring, storage tanks, silos, hoppers and industrial process vessels. Select the range and installation arrangement for the material surface and available measuring distance.
| Model | Construction |
|---|---|
| ELE-808B | Integrated ultrasonic level transmitter |
| ELE-809 | Split ultrasonic level transmitter with separate host and probe |
| Parameter | Specification |
|---|---|
| Range options | 0-4m, 0-7m, 0-10m, 0-15m or 0-20m |
| Accuracy | ±0.5% |
| Resolution | 1mm |
| Measurement blind zone | 0.3-0.55m |
| Temperature compensation | Built in |
| Protection | IP65 standard; IP66 available as an option |
| Ambient temperature | -25°C to 65°C |
| Power supply options | 24VDC, 150mA; or 220VAC, 100mA |
| Housing | ABS plastic |
| Output options | 4-20mA or RS485 communication |
Specify the integrated or split construction, measuring range, supply and output when selecting a unit. Allow for the 0.3-0.55m blind zone between the probe and the closest measured surface. IP66 protection and customized functions are available for applications requiring a different configuration.
ELE-700 and ELE-700-20 use aluminium alloy explosion-proof integrated housings. ELE-807 and ELE-808 configurations use integrated ABS housings. The ELE-809 family separates the probe from the display/controller. Relay options depend on the exact model.
| Model | Construction | Housing | RS485 | Optional relay outputs |
|---|---|---|---|---|
| ELE-700 | Integrated explosion-proof | Aluminium alloy | Optional four-wire | Not specified |
| ELE-700-20 | Four-wire available | 2 | ||
| ELE-808 | Integrated | ABS engineering plastic | Optional four-wire | Not specified |
| ELE-808-20 | Four-wire available | 2 | ||
| ELE-807 | Optional four-wire | Not specified | ||
| ELE-807-20 | Four-wire available | 2 | ||
| ELE-809 | Split probe and controller | Optional four-wire | Not specified | |
| ELE-809-20 | Four-wire available | 2 | ||
| ELE-809-40 | 4 |
| Parameter | Listed ELE-700, ELE-807, ELE-808 and ELE-809 configurations |
|---|---|
| Range selections | 1–10m or 1–20m |
| Measured media | Noncorrosive liquids and solids |
| Process connection | M59×2 |
| Current output | 4–20mA, two-wire signal configuration |
| Power choices | 24VDC or 220VAC |
| Electrical connection | Waterproof connector |
| Accuracy | ±0.5% |
| Temperature | -25–65°C |
| Protection | IP65 |
| Blind zone | 0.3–0.55m |
| Resolution | 1mm |
Choose the supply and output together, and use the wiring diagram for the supplied configuration. Allow for the blind zone when setting the highest liquid or material level. The ELE-809-40 designation identifies the listed four-relay option; select its measuring range independently from the model suffix.