The head-type ELE-805 and ELE-805S use a custom process flange below an enclosed electronics head. ELE-805S adds a local display. The sensing assembly uses a silicon pressure element and a 316L stainless steel isolation diaphragm, with signal conditioning in the transmitter housing.
| Parameter | ELE-805 head type | ELE-805S head type |
|---|---|---|
| Process mounting | Custom flange | |
| Local indication | No display in the illustrated head | Digital display |
| Head width | 105mm | |
| Head height | 110mm | |
| Flange thickness in the reference drawing | 17mm | |
| Head fixing thread callouts | M4 and M6 | |
| Neck length and flange drilling | Specified for the installation | |
| Parameter | Family configuration choices |
|---|---|
| Pressure reference | Gauge, absolute or vacuum |
| Output | 4–20mA standard; voltage or RS485 configurations available |
| Nominal DC supply | 24VDC; 12–30V operating range |
| Accuracy choices | ±0.1%, ±0.25%, ±0.5% or ±1% |
| Standard overload | 150% of the measuring range |
| Compatible media | Liquid or gas that does not corrode the selected wetted materials |
Specify the calibrated range, flange dimensions and pressure rating, neck length, wetted materials, output and accuracy together. Use the terminal-block diagram for the selected current, voltage or RS485 configuration. Isolate and depressurize the process before installation or removal.