ELE-802 transmitters measure liquid level from hydrostatic pressure. The stainless steel probes are immersed directly in the liquid and provide an electrical signal for a monitoring or control system. Applications include storage and fire-water tanks, wells, reservoirs, municipal water systems, irrigation and compatible wastewater processes.
| Model | Configuration | Selection focus |
|---|---|---|
| ELE-802 | General-purpose submersible probe | Analog current, analog voltage or RS485 output; optional companion display |
| ELE-802T | RS485 submersible probe | Remote digital monitoring and a shielded vented cable |
| ELE-802E | Anti-clogging probe | Dense 1mm filter holes for liquids containing particles or sediment |
| ELE-802L | Lightning and surge-protected probe | Outdoor water monitoring with integrated electrical interference protection |
| Parameter | ELE-802 |
|---|---|
| Measuring range | 0.4-60m; customizable |
| Measurement type and medium | Gauge pressure; noncorrosive liquids |
| Housing / diaphragm | 304 stainless steel / 316L stainless steel |
| Accuracy | ±0.5%FS standard; ±0.2%FS or ±0.1%FS optional; ±0.25%FS configuration also available |
| Overload capacity | 2× rated range |
| Outputs and wiring | 4-20mA, two-wire; RS485, four-wire; 0-5V or 0-10V, three-wire |
| Supply | 24VDC nominal; 10-30VDC |
| Protection | IP68; three-layer waterproof structure |
| Working temperature | -10°C to 70°C |
| Humidity | 0-95% |
| Cable | Double copper shielding |
| Process connections | Threaded connection; customized threaded or flange arrangements |
| Calibration | Factory calibration, aging test and recalibration |
| Verification reference | JJG 882-2019, Pressure Transmitters |
The 3mm pressure guide holes use a 45° angled arrangement to reduce direct contact between sharp objects and the sensing element. A wafer pressure sensor and layered protective construction form the measuring assembly. The bar-graph unit shown with the probe is a separate companion indicator.




| Parameter | ELE-802T |
|---|---|
| Measurement and installation | Hydrostatic liquid level; direct submersible installation |
| Output | RS485 |
| Accuracy | ±0.5%FS standard; ±0.2%FS or ±0.1%FS optional |
| Protection | IP68 |
| Probe housing | 304 stainless steel standard; 316 stainless steel optional |
| Diaphragm | 316L stainless steel |
| Cable | Vented polyethylene cable with internal pure-copper shielding |
| Pressure inlet | Three 3mm holes spaced at 120° intervals |
| Calibration | High-precision equipment calibration and pre-shipment aging test |
| Customization | Measuring range, cable length, materials, accuracy and output configuration |



ELE-802E uses a dense pattern of 1mm filter holes to reduce the entry of suspended particles and sediment while transmitting liquid pressure to the sensor. It is intended for compatible sewage, well-water and industrial wastewater applications where clogging is a concern.

| Parameter | ELE-802E |
|---|---|
| Measurement principle | Submersible hydrostatic pressure |
| Measuring range | 0.2-200mH₂O; customizable to 300m |
| Output | 4-20mA |
| Accuracy | ±0.5%FS standard; ±0.2%FS or ±0.1%FS optional |
| Supply | 24VDC nominal; 10-30VDC |
| Protection | IP68 |
| Medium temperature | 2°C to 50°C |
| Overload capacity | 150%FS |
| Long-term stability | ±0.1%FS/year |
| Temperature drift | ±0.01%FS/°C |
| Measuring medium | Liquids noncorrosive to the wetted materials |
| Probe housing | 304 stainless steel standard; 316 stainless steel optional |
| Diaphragm | 316L stainless steel |
| Cable | Shielded vented cable with braided copper shielding |
| Electrical connection | European-style terminal block |
| Signal wiring configurations | Two-wire current; three-wire voltage; optional four-wire RS485 |


ELE-802L combines a diffused-silicon piezoresistive sensor, a 316L isolation diaphragm and silicone-oil filling. Its integrated protection circuit addresses electrostatic discharge, surge impact and electrical fast transient interference in outdoor monitoring installations. The housing and cable support extended immersion in compatible liquids.

| Parameter | ELE-802L |
|---|---|
| Measurement type | Gauge pressure |
| Measuring range | 0.1-100m; customizable |
| Installation | Submersible |
| Measuring medium | Liquids noncorrosive to the wetted materials |
| Accuracy | ±0.5%FS standard; ±0.2%FS or ±0.1%FS optional |
| Output | 4-20mA standard; RS485 Modbus RTU optional |
| Supply | 24VDC nominal; 10-30VDC |
| Overload capacity | 150%FS |
| Protection | IP68 |
| Housing / diaphragm | 304 stainless steel / 316L stainless steel |
| Cable | Double-shielded copper cable |
| Pressure port | 3mm inlet holes with a 45° angled arrangement |
| Stability preparation | Factory calibration and aging test |
Match the liquid to the wetted materials, then choose the measuring range, output and cable length. Keep the model-specific overload and temperature ratings with the selected variant. ELE-802E addresses particle-related clogging; ELE-802L adds electrical surge protection; ELE-802T provides the stated RS485 configuration. Choose a compatible external indicator when local numerical or bar-graph display is required.
ELE-802F provides a separate corrosion-resistant submersible configuration for liquids compatible with PTFE and ceramic. Its 30mm probe has no threaded process connection and uses a remote cable termination.
| Parameter | ELE-802F |
|---|---|
| Range selections | 2–100mH₂O |
| Pressure reference | Gauge |
| Compatible media | Liquids compatible with PTFE and ceramic |
| Probe diameter | 30mm |
| Process connection | None; submersible probe |
| Output choices | Two-wire 4–20mA; three-wire 0–5V or 0–10VDC; four-wire RS485 |
| Electrical connection | European terminal, 0.5mm² |
| 4–20mA supply | 10–30VDC |
| 0–10V supply | 12–30VDC |
| Accuracy | ±0.5% |
| Overload | 1.5× full scale standard; special versions available |
| Temperature | 0–45°C |
| Protection | IP68 |
| Local LCD | None |