The ELE-801G3 uses a diffused silicon sensor and a finned cooling section for pressure measurement at medium temperatures up to 200°C. It supports water, gases, oils and hydraulic fluids that are compatible with the wetted materials. Applications include high-temperature pipelines, chemical process equipment, thermal systems and industrial fluid-power equipment.
The curved heat-sink structure separates the hot process connection from the sensing electronics. Automatic temperature compensation and linear correction condition the output signal. Each transmitter undergoes aging tests and calibration at zero, midpoint and full scale.
| Parameter | ELE-801G3 | ELE-801SG3 / ELE-801SG digital version |
|---|---|---|
| Sensor principle | Diffused silicon | |
| Media temperature | 0°C to 200°C | |
| Selectable range bands | ±200–800Pa; -100–900kPa; 1–100MPa, selected by configuration | |
| Pressure reference | Gauge or absolute | |
| Accuracy options | 0.5%FS standard; ±0.2% or ±0.5% configurations available | |
| Outputs | Two-wire 4–20mA; three-wire 0–5V or 0–10VDC; four-wire RS485 | |
| Supply for 4–20mA | 10–30VDC | |
| Supply for 0–10V | 12–30VDC | 15–30VDC |
| Electrical connection | Hirschmann connector | |
| Process thread options | Male M20×1.5, G1/4, G3/8, G1/2, NPT1/4, NPT3/8 or NPT1/2; customization available | |
| Wetted material compatibility | Liquids and gases compatible with 304 stainless steel | |
| Diaphragm | 316 stainless steel, silicone-oil-filled sensing assembly | |
| Overload | 1.5× full scale as standard; special versions can be customized | |
| Pressure port | 3mm port with damping element | |
| Protection | IP65 | |
| LCD | None | 4 digits as standard |
Choose the pressure span, output and supply as one configuration. The digital model adds local pressure indication to the cooled transmitter body.



The following dimensions describe the illustrated 801G3 construction. All values are in mm.
| Dimension | ELE-801G3 | ELE-801SG3 |
|---|---|---|
| Connector height | 39.5 | 42 |
| Display section height | Not fitted | 51.5 |
| Body diameter | 26.5 | |
| Main body length | 63 | |
| Heat sink / hex section | 64 | |
| Hex size | 27 | |
| Thread length | 20 | |
For a two-wire 4–20mA version, pin 1 is loop positive and pin 2 is loop negative. Use either a powered indicator or a separate 24VDC supply in the series loop. For a three-wire voltage version, pin 1 is supply positive, pin 2 is common negative and pin 3 is signal positive. The English attachment includes these circuits and the configuration-specific RS485 assignment.
Match the actual nameplate and connector markings before connection. The 200°C rating applies to the selected high-temperature sensing construction; keep the electronics within their configured operating conditions and allow the cooling section to dissipate heat.