ELE-800R and ELE-800RS use glass-microfused pressure sensing for gauge-pressure measurement in liquids and gases compatible with 304 stainless steel. The head enclosure provides an M20×1.5 electrical entry. ELE-800RS adds local LCD indication.
| Parameter | ELE-800R | ELE-800RS |
|---|---|---|
| Configuration | Glass-microfused pressure transmitter | Digital glass-microfused pressure transmitter |
| Range selections | 0.5–300MPa | |
| Pressure reference | Gauge | |
| Accuracy options | ±0.2% or ±0.5% | |
| Temperature | 0–60°C | |
| Compatible media | Liquids and gases compatible with 304 stainless steel | |
| Process threads | M20×1.5, G1/4 or G1/2 | |
| Electrical entry | M20×1.5 | |
| Output choices | Two-wire 4–20mA; three-wire 1–5V or 2–10VDC; four-wire RS485 | |
| 4–20mA supply | 10–30VDC | 12–30VDC |
| 2–10V supply | 12–30VDC | |
| Overload | 1.5× full scale standard; special versions available | |
| Gas explosion-protection designation | Ex d IIC T6 Gb | |
| Dust protection designation | Ex tD A21 IP66 T80°C | Not specified |
| LCD | None | 4 digits by default; selectable 5-digit mode |
Select the pressure span and the process connection as a complete rated assembly. Current, voltage and RS485 outputs are configuration choices. The dust designation above applies to ELE-800R; select the exact enclosure and marking required for the installation.