ELE-800R Glass-Microfused Pressure Transmitters

Description

High-pressure measurement with glass-microfused sensing

ELE-800R and ELE-800RS use glass-microfused pressure sensing for gauge-pressure measurement in liquids and gases compatible with 304 stainless steel. The head enclosure provides an M20×1.5 electrical entry. ELE-800RS adds local LCD indication.

Technical specifications

ParameterELE-800RELE-800RS
ConfigurationGlass-microfused pressure transmitterDigital glass-microfused pressure transmitter
Range selections0.5–300MPa
Pressure referenceGauge
Accuracy options±0.2% or ±0.5%
Temperature0–60°C
Compatible mediaLiquids and gases compatible with 304 stainless steel
Process threadsM20×1.5, G1/4 or G1/2
Electrical entryM20×1.5
Output choicesTwo-wire 4–20mA; three-wire 1–5V or 2–10VDC; four-wire RS485
4–20mA supply10–30VDC12–30VDC
2–10V supply12–30VDC
Overload1.5× full scale standard; special versions available
Gas explosion-protection designationEx d IIC T6 Gb
Dust protection designationEx tD A21 IP66 T80°CNot specified
LCDNone4 digits by default; selectable 5-digit mode

Configuration selection

Select the pressure span and the process connection as a complete rated assembly. Current, voltage and RS485 outputs are configuration choices. The dust designation above applies to ELE-800R; select the exact enclosure and marking required for the installation.