The ELE-800G3 family combines a finned pressure connection with a sealed instrument head for high-temperature process measurement. ELE-800G3 has no local LCD; ELE-800SG3 adds digital indication. Applications include industrial equipment, hydraulic and pneumatic systems, water supply, chemical and pharmaceutical processes, power generation, metallurgy and vacuum equipment.

The construction uses a 304 stainless steel threaded connection, a polished and painted exterior, sealing rings and a laser-marked nameplate. A sealed electrical interface helps limit moisture and dust entry.
| Parameter | Specification |
|---|---|
| Accuracy | ±0.5%FS as standard; ±0.2%FS optional |
| Nominal supply | 24VDC |
| Measuring span | Customized ranges from vacuum to 100MPa |
| Outputs | 4–20mA as standard; optional 0–10V, 0–5V or RS485 |
| Response time | <1s |
| Operating / ambient temperature | 0–150°C |
| Temperature compensation range | 0–70°C |
| Maximum medium temperature | 200°C |
| Ambient humidity | <90%RH |
| Protection | IP65 |
| Transmission distance | ≤100m |
| Overload pressure | 150% of full scale |
| Sealing | Protective rings at sealing points reduce moisture and gas ingress |
| Housing and process-fitting material | 304 stainless steel construction |
| Parameter | ELE-800G3 | ELE-800SG3 |
|---|---|---|
| Display | None | Four-digit LCD as standard; five digits selectable |
| Selectable range bands | ±200–800Pa; -100–900kPa; 1–100MPa | ±200–900Pa; -100–900kPa; 1–100MPa |
| Pressure reference | Gauge or absolute | |
| High-temperature medium range | 0–200°C | |
| Process connections | M20×1.5, G1/4, G3/8, G1/2, NPT3/8, NPT1/4 or NPT1/2; custom versions available | |
| Electrical entry | M20×1.5 | |
| Current output | Two-wire 4–20mA | |
| Current-output supply | 10–30VDC | 12–30VDC |
| Voltage-output choices | Three-wire 1–5V or 0–10VDC | Three-wire 0–5V, 1–5V, 0–10V or 2–10VDC |
| Voltage-output supply | 12–30VDC | |
| Communication option | Four-wire RS485 | |
| Accuracy choices | ±0.2% or ±0.5% | |
| Overload | 1.5× full scale; custom versions available | |
| Media compatibility | Liquids and gases compatible with 304 stainless steel | |
| Explosion-protection configuration | Ex d IIC T6 Gb | |

Select the measuring span, output, process thread and display requirement together with the process and ambient temperatures. For an explosion-protection configuration, apply the temperature conditions on the supplied instrument marking; the general high-temperature limits do not establish the T6 operating envelope. The English catalogue includes both G3 and SG3 model tables.