ELE-3051TL Flanged HART Level Transmitter

Description

Single-flange hydrostatic level measurement

ELE-3051TL measures liquid level from gauge pressure at a single flange connection. A monocrystalline silicon sensor provides two-wire 4–20mA with HART communication. Flange sizes and wetted material choices allow the transmitter to be selected for the tank connection and liquid.

Technical specifications

ParameterELE-3051TL
TypeSingle-flange level transmitter
Range selections1–400mH₂O
Pressure referenceGauge
SensorMonocrystalline silicon
Process flange optionsDN25, DN50, DN80 or DN100
Compatible liquids / wetted material choices316 stainless steel, Hastelloy C, Monel, tantalum or PTFE
OutputTwo-wire 4–20mA with HART
Supply10.5–42VDC
Accuracy options±0.075% to ±0.2%
Temperature-20–60°C
Turndown ratio10:1
Overload options2, 4, 20 or 60MPa, selected by configuration
Electrical entryM20×1.5
Explosion-protection designationEx d IIC T6 Gb

Application selection

Specify the liquid, calibrated head range, flange size, wetted material and required accuracy. The mH₂O range expresses water-equivalent pressure head; the level calibration must account for the measured liquid's density. Select the complete flange assembly and overload configuration for the process pressure.