EHT Digital and Bar Graph Liquid Level Indicators

Description

Numeric and bar graph level indication

EHT indicators show the measured value on an LED numeric display and present the relative level on an illuminated bar graph. The two displays help operators read a value and see the tank's level position at a glance.

The instrument processes an external measurement signal. A compatible liquid-level transmitter is required to measure the liquid and send the signal to the indicator. Select the transmitter separately for the tank, liquid, measuring range and installation conditions.

Technical specifications

ParameterSpecification
SeriesEHT
Instrument functionSignal processing and liquid-level indication
DisplayLED numeric display and illuminated bar graph
Accuracy class±0.5%FS; ±0.1%FS option
InputUniversal configurable input; match the selected signal configuration
Supply220VAC, 50Hz
Instrument depth90mm
Weight650g
Parameter retentionSettings retained after power loss
Parameter accessPassword protection
CommunicationsCustomized communication configurations available

The indicator's accuracy class applies to its configured signal processing and display. Complete measurement-system performance also depends on the external transmitter and the selected measuring range.

Configurable signal processing

Setting groupAdjustment or selection
Input and rangeInput signal type, measuring range and zero point
Measurement adjustmentMeasured-value zero and gain adjustment
Alarm settingsAlarm mode selection
Output settingsOutput mode and transmitter-output adjustment
CompensationDigital cold-junction compensation with internal or external selection for applicable input types
Access and storagePassword-protected parameters with nonvolatile retention

Set the input and display range to correspond to the transmitter's output and full-scale level. Choose the required alarm and output behavior for the monitoring system. Specify any communication option together with its interface and receiving-system requirements.

System integration

EHT indicators suit local tank monitoring, water and wastewater systems, industrial storage and process-control panels. Select the external transmitter for the liquid and installation, then match its electrical signal to the indicator's configured input.

Provide installation space for the 90mm instrument depth and verify the panel opening and terminal access against the supplied unit. Check scaling, alarm operation and retained settings during commissioning. The indicator is a panel instrument; submersible probe protection and wetted-material ratings belong to the separately selected transmitter.