The 800AS uses a hard flat diaphragm and strain-gauge sensing to measure gauge pressure in liquids and gases compatible with its wetted materials. The diaphragm structure helps resist blockage in slurry, mud and mineral pulp, making the transmitter suitable for mining, tailings pipelines, pulp handling and wastewater systems.
A silicon sensing element and precision signal-conditioning circuit provide rapid sampling and interference resistance. The stress-slot diaphragm design supports measurement at lower pressure ranges. The explosion-proof enclosure can be fitted with a four-digit LCD behind a high-strength glass window.


| Parameter | Specification |
|---|---|
| Pressure reference | Gauge pressure |
| Measuring media | Liquids and gases that do not corrode the wetted materials |
| Selectable pressure ranges | 500–900kPa and 1–60MPa |
| Accuracy | ±0.5%FS as standard; ±0.2%FS optional |
| Medium temperature | 0–60°C |
| Current output and supply | 4–20mA as standard; 10–30VDC supply |
| Voltage output and supply | Optional 0–10V; 12–30VDC supply |
| Digital output | Optional RS485 with Modbus-RTU |
| Overload capability | 150% of full scale |
| Temperature drift | ±0.01%FS/°C |
| Long-term stability | ±1%FS/year |
| Display | Optional four-digit LCD |
| Diaphragm and sensing | Hard flat diaphragm; strain-gauge sensing |
| Construction | Anti-clogging diaphragm and explosion-proof enclosure |

Select the pressure range, output and display configuration for the application. Analog outputs suit conventional receiving instruments, while RS485 supports digital communication with a compatible control system. Chemical-process equipment, hydraulic systems and industrial liquid or gas installations can use the same family when the medium is compatible with the wetted construction.
ELE-800A provides a hard flat diaphragm without a local display. ELE-800SA adds a four-digit LCD with a selectable five-digit mode. These configurations retain their own output and supply selections alongside the 800AS specifications above.
| Parameter | ELE-800A | ELE-800SA |
|---|---|---|
| Pressure range selections | 0.5–60MPa | |
| Pressure reference | Gauge | |
| Accuracy | ±0.5% | |
| Temperature | 0–60°C | |
| Compatible media | Liquids and gases compatible with 304 stainless steel | |
| Process connections | M20×1.5 or G1/2 | |
| Output choices | Two-wire 4–20mA; three-wire 1–5V or 2–10VDC; four-wire RS485 | |
| Supply for 4–20mA | 10–30VDC | 12–30VDC |
| Supply for 2–10V | 12–30VDC | |
| Overload | 1.5× full scale standard; special configurations available | |
| Electrical entry | M20×1.5 | |
| Explosion-protection designation | Ex d IIC T6 Gb | |
| LCD | None | 4 digits; selectable 5-digit mode |
Select the exact model, output, pressure span and process thread. The supply entries apply to the stated output configuration.