ELE-800A and 800AS Hard Flat-Diaphragm Pressure Transmitters

Description

Hard flat diaphragm for clog-prone media

The 800AS uses a hard flat diaphragm and strain-gauge sensing to measure gauge pressure in liquids and gases compatible with its wetted materials. The diaphragm structure helps resist blockage in slurry, mud and mineral pulp, making the transmitter suitable for mining, tailings pipelines, pulp handling and wastewater systems.

A silicon sensing element and precision signal-conditioning circuit provide rapid sampling and interference resistance. The stress-slot diaphragm design supports measurement at lower pressure ranges. The explosion-proof enclosure can be fitted with a four-digit LCD behind a high-strength glass window.

800AS pressure-sensing element detail
The sensing assembly converts diaphragm strain into a pressure signal.
Hard flat diaphragm on a threaded pressure connection
A flat sensing face reduces recesses in which viscous media can accumulate.

Technical specifications

ParameterSpecification
Pressure referenceGauge pressure
Measuring mediaLiquids and gases that do not corrode the wetted materials
Selectable pressure ranges500–900kPa and 1–60MPa
Accuracy±0.5%FS as standard; ±0.2%FS optional
Medium temperature0–60°C
Current output and supply4–20mA as standard; 10–30VDC supply
Voltage output and supplyOptional 0–10V; 12–30VDC supply
Digital outputOptional RS485 with Modbus-RTU
Overload capability150% of full scale
Temperature drift±0.01%FS/°C
Long-term stability±1%FS/year
DisplayOptional four-digit LCD
Diaphragm and sensingHard flat diaphragm; strain-gauge sensing
ConstructionAnti-clogging diaphragm and explosion-proof enclosure

Local indication and configuration

800AS illuminated local LCD pressure display
The optional LCD allows pressure readings directly at the instrument.

Select the pressure range, output and display configuration for the application. Analog outputs suit conventional receiving instruments, while RS485 supports digital communication with a compatible control system. Chemical-process equipment, hydraulic systems and industrial liquid or gas installations can use the same family when the medium is compatible with the wetted construction.

ELE-800A and ELE-800SA configurations

ELE-800A provides a hard flat diaphragm without a local display. ELE-800SA adds a four-digit LCD with a selectable five-digit mode. These configurations retain their own output and supply selections alongside the 800AS specifications above.

ParameterELE-800AELE-800SA
Pressure range selections0.5–60MPa
Pressure referenceGauge
Accuracy±0.5%
Temperature0–60°C
Compatible mediaLiquids and gases compatible with 304 stainless steel
Process connectionsM20×1.5 or G1/2
Output choicesTwo-wire 4–20mA; three-wire 1–5V or 2–10VDC; four-wire RS485
Supply for 4–20mA10–30VDC12–30VDC
Supply for 2–10V12–30VDC
Overload1.5× full scale standard; special configurations available
Electrical entryM20×1.5
Explosion-protection designationEx d IIC T6 Gb
LCDNone4 digits; selectable 5-digit mode

Select the exact model, output, pressure span and process thread. The supply entries apply to the stated output configuration.