The 2088 family combines a diffused-silicon pressure sensor with a spray-coated metal enclosure, sealed joints and a stainless steel cable gland. EPT-800 is the standard version; EPT-800S adds an LCD protected by tempered glass. A 304 stainless steel process connection accommodates compatible liquids, gases and vacuum-pressure applications.
Applications include petroleum processing, chemical plants, environmental systems, heating equipment, gas monitoring and industrial automation. The enclosure provides IP65 protection, while the signal circuit offers interference resistance and a 0.1s response.
| Parameter | Specification |
|---|---|
| Sensor | Diffused silicon |
| Accuracy | ±0.5%FS as standard; ±0.2%FS optional |
| Operating temperature | 0–60°C |
| Overload capacity | 150% of full scale |
| Response time | 0.1s |
| Explosion-protection designation | Ex db IIC T6 Gb |
| Ingress protection | IP65 |
| Current output | Two-wire 4–20mA as standard |
| Voltage outputs | Three-wire 0–5V, 0–10V or 0.5–4.5V |
| Digital communication | Four-wire RS485, Modbus-RTU |
| Supply | 10–30VDC for current output; 12–30VDC for voltage output |
| Process thread | M20×1.5 as standard; G1/2 or G1/4 optional |
| Process-connection material | 304 stainless steel |
| Local indication | LCD on EPT-800S; no LCD on EPT-800 |
ELE-800 instruments use a high-strength aluminum-alloy junction box, a 304 stainless steel pressure connection and a 316L stainless steel diaphragm. The circuit incorporates automatic temperature compensation, linear calibration and electrical isolation between the power supply and sensing signal. Copper terminals and durable laser markings support installation and identification.
| Parameter | ELE-800 / ELE-800S specification |
|---|---|
| Reference measuring span | 0–1MPa; other ranges can be configured |
| Selectable range bands | ±200–800Pa; -100–900kPa; 1–100MPa |
| Pressure reference | Gauge as standard; absolute available on request |
| Accuracy choices | ±0.5%; ±0.2% available on request |
| Temperature drift | 0.03%FS/°C |
| Long-term drift | ≤0.2%FS/year |
| Overload capacity | 3× rated range |
| Operating temperature | 0–50°C |
| Supply | 24VDC nominal; 12–30VDC operating range |
| Outputs | 4–20mA as standard; 0–5VDC or 0–10VDC; optional RS485 Modbus-RTU |
| Additional voltage configurations | 1–5V; ELE-800 also has a 2–10VDC option |
| Output wiring | Two-wire current; three-wire voltage; four-wire RS485 |
| Process connection | M20×1.5 as standard; G1/4, G3/8, G1/2, NPT3/8, NPT1/4 or NPT1/2 choices; custom sizes available |
| Electrical entry | M20×1.5 |
| Wetted materials | 304 stainless steel pressure fitting and 316L stainless steel diaphragm |
| Media | Liquids and gases noncorrosive to the wetted stainless steel, including compatible water, air and oil |
| Protection | IP65 |
| Explosion-protection designations | ELE-800: Ex d IIC T6 Gb and Ex tD A21 IP66 T80°C configurations; ELE-800S: Ex d IIC T6 Gb |
| Local indication | ELE-800 without LCD; ELE-800S with four-digit LCD as standard and selectable five-digit display |
These configurations provide continuous pressure signals for PLC or DCS inputs in industrial processes, water systems, tanks, reservoirs and boiler-related pressure monitoring. Select the housing and protection configuration for the installation.
Specify the measuring range, gauge or absolute reference, accuracy, output, thread and display requirement. Match the supplied instrument marking to the installation requirements. Use the terminal assignment for the supplied configuration; current, voltage and RS485 versions use different circuits. The English pressure and level transmitter manual includes wiring, dimensional drawings and installation instructions.