MCY T-Type Photovoltaic Branch Cable Assemblies

Series Part Number

Part Number: ULO - MCY - 3T
Explanation:

Brand

Series

MCY - 1000V photovoltaic branch cable assembly

Junction Layout

2T - Two distributed T-junctions; standard 4mm² conductors
3T - Three distributed T-junctions; standard 2.5mm², 4mm² or 6mm² conductors; use conductor-dependent current ratings in Description

Description

Distributed T-junction layouts

MCY T-type assemblies position branch leads along a common cable run. The 2T model has two T-junctions; the 3T model has three. Each photograph shows the complementary connector arrangements.

ModelT-junctions per assemblyStandard conductor sizesRated voltage
ULO-MCY-2T24mm²1000V
ULO-MCY-3T32.5mm², 4mm² or 6mm²

Conductor-dependent current

Both models have the following current conditions. These conditions are separate from the standard conductor lists above; the standard 4mm² assembly corresponds to the 30A condition.

Conductor cross-sectionRated current
1.5mm²17A
2.5mm²22.5A
4-6mm²30A

Common connector specifications

ParameterSpecification
Connection systemMultipoint connection
Connection methodCrimping
Locking systemEmbedded
Contact resistance≤0.35mΩ
Protection levelIP68
DC safety classII
Ambient temperature-40°C to +90°C
Temperature tolerance-40°C to +135°C
Insulation material / groupPPO / I
Flammability classificationUL94V-0
Contact material / finishBrass / tin plated

Select the number of junctions, cable arrangement and conductor size together. Branch count does not multiply the common connection current rating. Cable lengths and junction spacing are not specified by the model code.