| Part Number: | ULO | - | CC03 | - | M12 | A | - | 04 | P | - | MM | - | PM | SH | - | SL | A | 01 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Explanation: |
Code Prefix |
Series |
Connector Size M12 - M12×1 connector |
Coding A - A coding; 03, 04, 05, 06 or 08 contacts |
Contacts 03 - 3 contacts; A coding |
Contact Unit |
Gender MM - Male connector |
Assembly Code PM - Fixed code for these premolded cable assemblies |
Shielding SH - Shielded cable |
Body SL - Straight connector |
Jacket A - PVC jacket, UL2517 cable designation |
Cable Length 01–99 - 1–99m; retain two digits |
These black sensor and actuator assemblies combine one molded M12 connector with a cut cable end. Straight SL and angled SR bodies are available with male MM or female FF contacts. Choose the contact gender, coding and contact count together; M12 thread size alone does not establish electrical or mechanical interchangeability.
| Model pattern | Contact gender | Body | Reference envelope | Coupling diameter |
|---|---|---|---|---|
| CC03-M12X-XXP-MM-PMXX-SLXXX | Male | Straight | 42.5mm length | Ø14.5mm |
| CC03-M12X-XXP-FF-PMXX-SLXXX | Female | 46.3mm length | Ø14.4mm | |
| CC03-M12X-XXP-MM-PMXX-SRXXX | Male | Angled | 40×22.8mm | Ø14.5mm |
| CC03-M12X-XXP-FF-PMXX-SRXXX | Female | 40×24mm | Ø14.4mm |
All four use an M12×1 thread. The body dimensions are reference dimensions; cable length L is indicated separately in each outline.




| Coding | Contacts | Rated voltage | Rated current | Withstand voltage |
|---|---|---|---|---|
| A | 3 | 250V | 4A | 1500VAC |
| 4 | ||||
| 5 | 60V | 1200VAC | ||
| 6 | 30V | 2A | 650V | |
| 8 | ||||
| B | 5 | 60V | 4A | 1120V |
| D | 4 | 250V | 1500V |
Withstand values are test specifications, not operating voltages; test duration is unspecified. Only the coding/contact combinations listed above are included. Contact resistance is ≤3mΩ, protection is IP67, operating temperature is -40°C to +85°C and mechanical life is greater than 50 mating cycles.
The table gives contact numbers and conductor colors for the defined configurations. A-coded six-contact cables require an additional pin-position check: their grey and pink conductor entries do not have an established correspondence to the markings in the six-contact face illustration.
| Contact / entry | A 3-contact | A 4-contact | A 5-contact | A 6-contact entries | A 8-contact | B 5-contact | D 4-contact |
|---|---|---|---|---|---|---|---|
| 1 | Brown | White | Brown | ||||
| 2 | Not fitted | White | Brown | White | |||
| 3 | Blue | Green | Blue | ||||
| 4 | Black | Yellow | Black | ||||
| 5 | Not fitted | Grey | Grey; face position unassigned | Grey | Not fitted | ||
| 6 | Not fitted | Pink; face position unassigned | Pink | Not fitted | |||
| 7 | Not fitted | See six-contact note | Blue | Not fitted | |||
| 8 | Not fitted | Red | Not fitted | ||||
For the six-contact version, the conductor list uses entries 1–6, while the illustrated face is marked 1, 2, 3, 4, 6 and 7. Do not infer that the pink wire connects to the face marking 6 or assign grey to marking 7 without checking the selected assembly.
| Order field | Available specification |
|---|---|
| Coding X | A, B or D within the contact combinations above |
| Contact-count field | 03, 04, 05, 06 or 08 as applicable to coding |
| Jacket A | PVC, UL2517 cable designation |
| Jacket B | PUR, UL20549 cable designation |
| Shielding | SH for shielded; omitted for unshielded |
| Length code | 01–99 for 1–99m |
| Nominal cable length | Length tolerance |
|---|---|
| 1–5m | ±50mm |
| 6–10m | ±100mm |
| 11–30m | ±200mm |
| 31–99m | ±500mm |
These jacket, shielding and length options apply to the four cable patterns on this page. The cable designations do not establish a certification for every completed assembly. Conductor cross-section, shield termination details and application-specific transmission performance are unspecified.
| Component | Material |
|---|---|
| Contacts | CuZn with gold contact surfaces |
| Contact carrier | PU |
| Molded body | TPU |
| Coupling ring | Nickel-plated copper alloy |
| Seal | Silicone |
| Listed flammability class | UL94V-0 |