M12 Premolded Sensor and Actuator Cables

Series Part Number

Part Number: ULO - CC03 - M12 A - 04 P - MM - PM SH - SL A 01
Explanation:

Code Prefix

Series

Connector Size

M12 - M12×1 connector

Coding

A - A coding; 03, 04, 05, 06 or 08 contacts
B - B coding; 05 contacts only
D - D coding; 04 contacts only

Contacts

03 - 3 contacts; A coding
04 - 4 contacts; A or D coding
05 - 5 contacts; A or B coding
06 - 6 contacts; A coding, subject to the six-contact wiring qualification on this page
08 - 8 contacts; A coding

Contact Unit

Gender

MM - Male connector
FF - Female connector

Assembly Code

PM - Fixed code for these premolded cable assemblies

Shielding

SH - Shielded cable
Blank - Unshielded cable; omit SH

Body

SL - Straight connector
SR - Angled connector

Jacket

A - PVC jacket, UL2517 cable designation
B - PUR jacket, UL20549 cable designation

Cable Length

01–99 - 1–99m; retain two digits

Description

Four molded M12 cable configurations

These black sensor and actuator assemblies combine one molded M12 connector with a cut cable end. Straight SL and angled SR bodies are available with male MM or female FF contacts. Choose the contact gender, coding and contact count together; M12 thread size alone does not establish electrical or mechanical interchangeability.

Model patternContact genderBodyReference envelopeCoupling diameter
CC03-M12X-XXP-MM-PMXX-SLXXXMaleStraight42.5mm lengthØ14.5mm
CC03-M12X-XXP-FF-PMXX-SLXXXFemale46.3mm lengthØ14.4mm
CC03-M12X-XXP-MM-PMXX-SRXXXMaleAngled40×22.8mmØ14.5mm
CC03-M12X-XXP-FF-PMXX-SRXXXFemale40×24mmØ14.4mm

All four use an M12×1 thread. The body dimensions are reference dimensions; cable length L is indicated separately in each outline.

Straight male M12 cable outline
Straight male MM-SL configuration, 42.5mm reference length.
Straight female M12 cable outline
Straight female FF-SL configuration, 46.3mm reference length.
Angled male M12 cable outline
Angled male MM-SR configuration, 40×22.8mm reference envelope.
Angled female M12 cable outline
Angled female FF-SR configuration, 40×24mm reference envelope.

Coding and electrical ratings

CodingContactsRated voltageRated currentWithstand voltage
A3250V4A1500VAC
4
560V1200VAC
630V2A650V
8
B560V4A1120V
D4250V1500V

Withstand values are test specifications, not operating voltages; test duration is unspecified. Only the coding/contact combinations listed above are included. Contact resistance is ≤3mΩ, protection is IP67, operating temperature is -40°C to +85°C and mechanical life is greater than 50 mating cycles.

Conductor colors

The table gives contact numbers and conductor colors for the defined configurations. A-coded six-contact cables require an additional pin-position check: their grey and pink conductor entries do not have an established correspondence to the markings in the six-contact face illustration.

Contact / entryA 3-contactA 4-contactA 5-contactA 6-contact entriesA 8-contactB 5-contactD 4-contact
1BrownWhiteBrown
2Not fittedWhiteBrownWhite
3BlueGreenBlue
4BlackYellowBlack
5Not fittedGreyGrey; face position unassignedGreyNot fitted
6Not fittedPink; face position unassignedPinkNot fitted
7Not fittedSee six-contact noteBlueNot fitted
8Not fittedRedNot fitted

For the six-contact version, the conductor list uses entries 1–6, while the illustrated face is marked 1, 2, 3, 4, 6 and 7. Do not infer that the pink wire connects to the face marking 6 or assign grey to marking 7 without checking the selected assembly.

Cable jacket, shielding and length

Order fieldAvailable specification
Coding XA, B or D within the contact combinations above
Contact-count field03, 04, 05, 06 or 08 as applicable to coding
Jacket APVC, UL2517 cable designation
Jacket BPUR, UL20549 cable designation
ShieldingSH for shielded; omitted for unshielded
Length code01–99 for 1–99m
Nominal cable lengthLength tolerance
1–5m±50mm
6–10m±100mm
11–30m±200mm
31–99m±500mm

These jacket, shielding and length options apply to the four cable patterns on this page. The cable designations do not establish a certification for every completed assembly. Conductor cross-section, shield termination details and application-specific transmission performance are unspecified.

Connector materials

ComponentMaterial
ContactsCuZn with gold contact surfaces
Contact carrierPU
Molded bodyTPU
Coupling ringNickel-plated copper alloy
SealSilicone
Listed flammability classUL94V-0