| Part Number: | ULO | - | HD09 | - | HMDD | - | 017 | - | MC |
|---|---|---|---|---|---|---|---|---|---|
| Explanation: |
Manufacturer ULO - ULO Electronics |
Product Code HD09 - Fixed product code for the listed HMDD modules |
Module Family HMDD - HMDD modular crimp insert |
Positions 017 - Seventeen contacts, one module, no PE contact |
Insert Version MC - Male crimp insert |
HMDD crimp carriers provide seventeen contact positions in a staggered arrangement. Each occupies one module position and has no PE contact. Select MC for the male carrier or FC for the female carrier.
| Model | Gender | Contacts | Module occupancy | Overall length |
|---|---|---|---|---|
| ULO-HD09-HMDD-017-MC | Male | 17 | One module | 34.8mm |
| ULO-HD09-HMDD-017-FC | Female | 35mm |
| Parameter | Both models |
|---|---|
| Termination | Crimp |
| Rated current | 10A |
| Rated voltage | 160V |
| Rated impulse voltage | 2.5kV |
| Pollution degree | 3 |
| Rated voltage according to UL/CSA | 250V |
| Insulation resistance | ≥10000MΩ |
| Contact resistance | ≤3mΩ |
| Conductor cross section | 0.14-2.5mm² |
| Wire range | 26-14AWG |
| PE contact | No |
| Connection standards | DIN EN 60664-1; DIN EN 61984 |
| Parameter | Specification |
|---|---|
| Insert material | Polycarbonate |
| Colour | Light grey, RAL 7032 |
| Contact material | Copper alloy |
| Contact finish | Silver plated |
| Flammability | UL94V-0 |
| Limiting temperature | -40°C to +125°C |
| Mechanical working life | ≥500 mating cycles |
| RoHS | Complies with applicable exemptions |
The HMDD-017-MC male carrier has a 14.6mm width and 34.8mm overall length. Its contact-face body dimension is 30.3mm, increasing to 34.1mm across the retaining features.

The HMDD-017-FC female carrier is 14.6mm wide and 35mm long. It shares the 30.3mm body dimension and 34.1mm dimension across the retaining features, with a projecting mating section.

Match the numbered contact arrangement, gender and retention geometry when specifying the frame and mating assembly. Select the crimp contact for the required conductor size.