Choose a coupling housing, a mounted base or a cable hood to suit the cable route and installation. H3A.P bodies are polycarbonate. Lever-equipped housings use an elastic polyamide locking lever; the matching hoods have two locking pegs.
| Model | Configuration | Cable entry | Locking features | Weight |
|---|---|---|---|---|
| H3A.P-DJK-1L-M20 | Cable coupling housing | One M20 entry | One lever | 15g |
| H3A.P-SG-1L-M20 | Surface-mounted housing | One M20 side entry | One lever | 15g |
| H3A.P-SK-2B-M20 | Side-entry hood | One M20 entry | Two pegs | 13.5g |
| H3A.P-ST-1L | Bulkhead-mounted housing | Bottom panel opening | One lever | 11g |
| H3A.P-ST-SK-1L | Angled bulkhead-mounted housing | Bottom panel opening | One lever | 17.2g |
| H3A.P-TK-2B-M20 | Top-entry hood | One M20 entry | Two pegs | 12g |
The threaded enclosure drawings also list PG11 options. Specify M20 or PG11 as the required thread; they are separate choices. Select the insert, gland and any protective cover for the complete assembly.
| Property | Value |
|---|---|
| Body material | Polycarbonate |
| Colour | Light grey, RAL7032 |
| Lever type | Elastic plastic pressing lever |
| Lever material | Polyamide |
| Seal material | NBR |
| Limiting temperatures | -40°C to +125°C |
| Flammability according to UL94 | V0 |
| Degree of protection | IP65 according to EN60529/IEC60529 for the coupled connector |
| Model | Selected dimensions |
|---|---|
| H3A.P-DJK-1L-M20 | 57mm body length; 35mm indicated width |
| H3A.P-SG-1L-M20 | 57mm body length; 40mm mounting width; 22×22mm panel opening; 30mm panel-hole spacing |
| H3A.P-SK-2B-M20 | 54.60mm height; 26.80mm body width; 35mm across peg projections |
| H3A.P-ST-1L | 40.20×28mm mounting flange; 22×22mm panel opening; 30mm panel-hole spacing |
| H3A.P-ST-SK-1L | 44.80mm body length; 40mm mounting width; 22×22mm panel opening; 30mm panel-hole spacing |
| H3A.P-TK-2B-M20 | 60mm height; 26.80mm body width; 35.20mm across peg projections |
The panel-opening drawings specify 3.20mm panel fixing holes. Consult each outline for flange holes, lever clearance and locating details. The stated IP65 protection requires a correctly coupled and locked assembly.