GYJ1 Industrial Contactor Relay

Description

The GYJ1 industrial contactor relay is designed for control-circuit switching and auxiliary control applications. The series provides five contact configurations, AC and DC control voltage options, IP20 protection, and installation by 35mm guide rail or screw fixing.

Key Features

  • Five main contact configurations for different control-circuit requirements.
  • AC control voltage options from 24V to 415V, plus DC options at 24V, 48V, 110V and 220V.
  • Rated insulation voltage and rated working voltage listed as 690V.
  • Agreed heating current of 10A at ambient temperature up to 40C.
  • Top auxiliary contact and interlock accessories are listed for the series.
  • Installed on a 35mm guide rail or fixed with screws.
  • Standards listed: IEC 60947-1, IEC 60947-5-1, GB 14048.5 and GB 14048.1.

Contact Configurations

Basic modelNormally open contactsNormally closed contactsControl circuit power consumption
GYJ104044.5VA
GYJ113134.5VA
GYJ122224.5VA
GYJ131314.5VA
GYJ140404.5VA

Electrical Ratings

Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp6kV
Rated working voltage Ue690V
Frequency range under working current50Hz, 50/60Hz
Agreed heating current Ith10A at ambient temperature up to 40C
Minimum switching capacityUmin 17V, Imin 5A
Overload current, 1s80A
Short-circuit protection10A gG fuse
Rated making capacity110A, compliant with IEC 60947 and GB 14048 standards

Control Circuit Data

AC rated control voltage, 50Hz/50/60Hz24V, 36V, 48V, 110V, 220V, 380V, 400V, 415V
DC rated control voltage24V, 48V, 110V, 220V
Pull-in range85% to 110% Us
Release rangeAC: 20% to 70% Us; DC: 10% to 70% Us
Average power consumption, start40VA
Average power consumption, release7VA
Average power consumption3-4W
Heat loss1.3W
Close time5-15ms
Open time10-20ms
Mechanical life12 million operations
Maximum operating frequency3600 operations per hour at ambient temperature up to 40C

Operating Environment

Pollution level2
Product certificateCCC, CQC
Protection levelIP20
Storage temperature-50C to +80C
Working temperature-40C to +70C
Allowable working temperature under Us-40C to +70C
Vibration resistance, contactor disconnected8gn
Vibration resistance, contactor closed10gn
Maximum working altitude without capacity reduction2000m
Working positionClass II; allows a 22.5 degree angle to the normal vertical installation surface without capacity reduction
Flame retardant performanceHousing and base V0 rating, IEC 60695-2-1 standard

Connection Data

CircuitFlexible cord without terminal blocksFlexible wire with terminal blocksHard wire without terminal blocksToolTightening torque
Main circuit wiring1 x 0.75-2 x 4mm21 x 0.34-1 x 1.5 + 1 x 2.5mm21 x 1.5-2 x 4mm2Ph2 cross screwdriver or 6mm flat slotted screwdriver1.2N.m
Control circuit connection1 x 0.75-2 x 4mm21 x 0.34-1 x 1.5 + 1 x 2.5mm21 x 1.5-2 x 4mm2Ph2 cross screwdriver or 6mm flat slotted screwdriver1.2N.m

Accessory Contacts

Accessory modelContacts per moduleContact formApplicable products
LA-KN-0220NO + 2NCGYJ1-06 to GYJ1-16M
LA-KN-1121NO + 1NCGYJ1-06 to GYJ1-16M
LA-KN-2022NO + 0NCGYJ1-06 to GYJ1-16M
LA-KN-0440NO + 4NCGYJ1-06 to GYJ1-16M
LA-KN-1341NO + 3NCGYJ1-06 to GYJ1-16M
LA-KN-2242NO + 2NCGYJ1-06 to GYJ1-16M
LA-KN-3143NO + 1NCGYJ1-06 to GYJ1-16M
LA-KN-4044NO + 0NCGYJ1-06 to GYJ1-16M