CZ-93 Key Actuated Safety Door Switches

Series Part Number

Part Number: CZ-93 C PM + K1
Explanation:

Series

CZ-93 - Key actuated safety door switch series

Contacts

B - 2NC
C - 1NC/1NO
Direct opening - Applies to NC contacts only

Cable entry

PM - M20×1.5
PG - PG11

Operating key

NONE - No operating key supplied; omit the key code and the preceding plus sign
K1 - Horizontal mounting
K2 - Vertical mounting
K3 - Adjustable horizontal mounting
K5 - Adjustable horizontal or vertical mounting

Description

Key actuated door position switching

CZ-93 switches use a separate operating key to actuate the contact mechanism as a door moves. Choose a 1NC/1NO contact block with code C or a 2NC block with code B. NC contacts have a direct-opening mechanism; this function does not apply to NO contacts. The housing has IP65 protection and an adjustable head orientation.

Choose the key mounting style and insertion path together. The five configurations below use the C contact block and PM cable entry. B contacts and PG cable entry are ordering options, not features included in every CPM configuration. A switch ordered without a key requires a separately specified matching key. No guard-locking function or system PL/SIL rating is specified.

Ordering options

SelectionCodeMeaning
SeriesCZ-93Key actuated safety door switch
Contact blockB2NC
C1NC/1NO
Cable entryPMM20×1.5
PGPG11
Operating keyOmittedNo key supplied; omit the plus sign and key code
K1Horizontal mounting
K2Vertical mounting
K3Adjustable horizontal mounting
K5Adjustable horizontal or vertical mounting

For example, CZ-93CPM+K1 specifies a 1NC/1NO switch with M20×1.5 entry and a K1 horizontal key. The hyphen belongs to the fixed series identifier CZ-93; the plus sign separates the optional key.

CZ-93 contact, cable entry and operating key ordering diagram
Ordering structure for contact block, cable entry and operating key. Direct opening applies to NC contacts only.

Key configuration and insertion geometry

ConfigurationKeyHorizontal insertion radiusVertical insertion radiusKey mounting surface setting
CZ-93CPMNone suppliedSelect a matching operating key before setting the installation geometry
CZ-93CPM+K1HorizontalAt least 200mmAt least 200mm44–46.5mm
CZ-93CPM+K2Vertical40–42.5mm
CZ-93CPM+K3Adjustable horizontalAt least 50mm45–47.5mm
CZ-93CPM+K5Adjustable horizontal or verticalAt least 50mm51.9–54.4mm

Mounting surface settings refer to the datums shown in the attached installation drawings. Key center alignment must remain within ±1mm of the insertion-slot center in both directions. Use the specified insertion radius and keep the key perpendicular to its slot. Adjustable-key drawings show 20° adjustment for K3, and 15° and 18° in the two illustrated planes for K5; use the drawings to match the adjustment plane to the door path.

Operating characteristicAll five CPM configurations
Key insertion force, maximum15N
Key extraction force, maximum30N
Pretravel PT6±3mm
Total travel TT28mm

Electrical and environmental characteristics

ParameterValue or condition
Rated operating load, AC-153A at 250VAC
Control-circuit designationA300
Rated insulation voltage Ui400V or 600V according to the individual product marking; select the marked version for the circuit
Conventional thermal current Ith10A
Rated impulse withstand voltage Uimp2.5kV
AC frequency50/60Hz
Operating speed0.05–0.5m/s
Initial contact resistance25mΩ maximum
Insulation resistance100MΩ minimum at 500VDC
Minimum standard-contact load24VDC, 10mA
Electrical durabilityMore than 100,000 cycles at 240VAC, 3A resistive load
Electrical durability, load unspecifiedMore than 150,000 cycles; do not apply this value to a particular load without its test conditions
Vibration resistance10–55Hz, 1.5mm double amplitude
Shock resistanceMechanical durability: approximately 1000m/s²; malfunction: approximately 300m/s²
Ambient temperature-25°C to +70°C, without icing
Ambient humidityBelow 95%RH
Ingress protectionIP65 with suitable cable entry sealing

The thermal current, general switching ratings and AC-15 operating rating describe different conditions. A 10A value in the general-load table is not a 10A AC-15 rating. AC frequency is not the permissible number of mechanical switching operations per second.

General switching ratings

SupplyVoltageNon-inductive loadInductive load group
ResistiveLampInductiveMotor
NCNONCNONCNONCNO
AC125V10A3A1.5A10A5A2.5A
250V2A1A3A1.5A
400V1.5A0.8A3A1.5A0.8A
DC8V10A6A3A10A6A
14V
30V6A4A6A4A
125V0.8A0.2A0.8A0.2A
250V0.4A0.1A0.4A0.1A

NO columns apply only where an NO contact is fitted. Use a suitable 10A gG/gI fuse complying with IEC 60269 for the specified short-circuit protection arrangement; no fuse is built into the switch. Select protection and wiring for the complete circuit.

CZ-93 general switching ratings by voltage, load and NC or NO contact
General load ratings preserve separate NC and NO limits for lamp and motor loads. The AC-15 rating remains 3A at 250VAC.
Specification referenceStandard
CCC specificationGB/T 14048.5
CE specificationEN 60947-5-1

Obtain the applicable model-specific documents where certification is required. The NC direct-opening mechanism provides mechanical separation of NC contacts; it does not establish a complete machine safety performance level.

Mounting and head positioning

Provide a separate mechanical door stop. Keep the operating key within the 0.5–3mm setting region so that its base cannot strike the switch head. Secure the door against movement caused by weight, vibration or rebound. Do not use the switch or key as a door stop, and do not exceed the stated shock limits.

Mount the body and key using M4 screws and spring washers. Use fasteners or equivalent measures that prevent easy removal. Body drawings show 20±0.1mm and 22±0.1mm mounting dimensions and 47±0.1mm vertical spacing; follow the applicable hole arrangement. Optional lower locating pins are at most 4.8mm high and Ø4mm with -0.05/-0.15mm tolerance. K1/K2 mounting centers are 15±0.1mm; K3 centers are 40±0.1mm. The K5 slotted arrangement is shown separately in the attachment.

Fastener or connectionTightening torque
Terminal screws0.6–0.8N·m
Outer cover mounting screws0.5–0.7N·m
Head mounting screws0.5–0.6N·m
Operating key mounting screws2.4–2.8N·m
Body mounting screws0.5–0.7N·m
Waterproof cable gland1.8–2.2N·m
Conduit closure cap1.3–1.7N·m

The head can be oriented in four directions after loosening its corner screws. Keep foreign material out and do not insert or remove the key while the head is detached. Use the designated matching key; do not substitute tools or force the mechanism. Avoid excessive force or impacts on an inserted key.

Wiring and cable entry

Isolate power before wiring. Use insulated M3.5 crimp terminals with 0.5–0.75mm² conductors, approximately AWG20–AWG18. Keep terminal thickness at or below 0.5mm, and position terminals so the cover closes without compressing them against the housing. Remove wire fragments before closing the enclosure.

Crimp terminal dimensionValue
Thickness t0.5mm maximum
Stud hole Ødz3.7mm
Barrel ØD2.9mm
Width B6.6mm
Length L19mm
Dimension F7.7mm
Dimension l8.0mm
Cable typeRecommended cable characteristics
CoresConductorOverall diameter
Plastic or rubber insulated flexible cable2, 3 or 40.75mm²Circular, Ø6–9mm
600V plastic insulated, plastic sheathed cable, VVF2Ø1mm, Ø1.2mm or Ø1.6mm

Match the gland sealing range to the cable diameter and its thread to the selected PM or PG entry. Use a gland with a threaded length of 9mm or less to avoid internal interference. Avoid silicone oil in wiring materials because it can affect contact reliability.

Contact use and application assessment

Standard contacts are intended for at least 24VDC and 10mA. Below this load, current may not break through surface films, so use a contact version specified for the signal level. Do not move a contact already used for general loads into a smaller-capacity signal circuit. Provide suitable contact suppression where arcing, noise or inrush affects operation.

Select and validate the complete door-monitoring arrangement for the machine. Applications involving exceptional reliability, hazardous atmospheres, severe environmental exposure, aerospace or military use require a specifically assessed design. The switch's component ratings do not replace that assessment.