| Part Number: | CDU | K | 32 | TF | - | 30 | D | - | A93 | L | S |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Explanation: |
Series and Magnet CU - Free-mount cylinder without a built-in magnet; omit magnetic-switch fields |
Rod Configuration Blank - Basic single rod; omit the configuration suffix |
Bore 6 - 6mm |
Port Thread Blank - Metric thread for bores 6–25mm; Rc thread for 32mm bore; omit the thread suffix |
Stroke 5, 10, 15, 20, 25, 30 - Standard double-acting strokes in mm for bores 6/10/16 |
Acting Type D - Double acting |
Magnetic Switch Blank - No switch; omit the switch code, preceding hyphen, lead-length code and quantity code |
Switch Lead Length Blank - 0.5m lead; omit the lead-length suffix |
Switch Quantity Blank - Two switches; omit the quantity suffix |
CU cylinders provide pneumatic motion in a body designed for mounting on multiple faces. Select a standard or non-rotating rod, single or double rods, the required action and a magnetic-piston option before choosing bore and stroke.
| Ordering field | Code | Selection |
|---|---|---|
| Magnet | Blank / D | Without / with built-in magnetic ring; CU / CDU family |
| Rod configuration | Blank | Basic single rod |
| Rod configuration | K | Non-rotating single rod |
| Rod configuration | W | Double rod |
| Rod configuration | KW | Non-rotating double rod |
| Bore | 6, 10, 16, 20, 25, 32 | Bore in millimeters |
| Port thread, 6–25mm bore | Blank | M5×0.8 |
| Port thread, 32mm bore | Blank / TN / TF | Rc / NPT / G, 1/8 size |
| Stroke | 30 | Example: 30mm |
| Action | D | Double acting |
| Action | S | Single acting, spring return |
| Action | T | Single acting, spring extend |
| Magnetic switch | Blank or selected model | No switch or selected switch; requires built-in magnet |
| Switch quantity | Blank / S | Two / one |
The example CDUK6□30D-A93□ specifies a magnetic, non-rotating cylinder with 6mm bore, 30mm stroke, double-acting operation and A93 switch; square placeholders indicate option positions. W and KW double-rod configurations are excluded from single-acting and long-stroke selections.
| Parameter | Specification |
|---|---|
| Medium | Air |
| Maximum operating pressure | 0.7MPa |
| Ambient and air temperature without switch | -10–70°C, nonfreezing |
| Ambient and air temperature with switch | -10–60°C, nonfreezing |
| Cushioning | Rubber cushions at both ends |
| Piston speed | 50–500mm/s |
| Stroke tolerance | 0 to +0.1mm |
| Lubrication | Not required |
| Mounting | Free mounting on multiple body faces |
Values are in MPa. Match both action and rod configuration; a shared bore does not give all versions the same starting pressure.
| Action | Rod configuration | 6mm bore | 10–16mm bore | 20–32mm bore |
|---|---|---|---|---|
| Double acting | Standard single rod | 0.12 | 0.06 | 0.05 |
| Standard double rod, W | 0.15 | 0.10 | 0.08 | |
| Non-rotating single rod, K | 0.15 | 0.10 | 0.08 | |
| Non-rotating double rod, KW | 0.18 | 0.13 | 0.11 | |
| Single acting | Standard single rod | 0.20 | 0.15 | 0.13 |
| Non-rotating single rod, K | 0.23 | 0.18 | 0.16 |
| Bore | Port | Non-rotating rod accuracy |
|---|---|---|
| 6mm, 10mm, 16mm | M5×0.8 | ±0.8° |
| 20mm, 25mm | M5×0.8 | ±0.5° |
| 32mm | 1/8, selected Rc/NPT/G thread | ±0.5° |
The angular figures apply to non-rotating rod configurations, not to unrestricted rotation of a standard round rod.
| Bore (mm) | Standard stroke (mm) | Long stroke, double acting (mm) | Direct-mount switch choices | |
|---|---|---|---|---|
| Double acting | Single acting | |||
| 6, 10, 16 | 5, 10, 15, 20, 25, 30 | 5, 10, 15 | 40, 50, 60 | A93, A96, M9N, M9B, M9P, F9NW |
| 20, 25, 32 | 5, 10, 15, 20, 25, 30, 40, 50 | 60, 70, 80, 90, 100 | ||
For spring-return operation, air extends the rod and the spring retracts it. For spring-extend operation, air retracts the rod and the spring extends it. Select magnetic switch model and quantity separately from the cylinder action and stroke.