CU Free-Mount Pneumatic Cylinders and Non-Rotating Options

Series Part Number

Part Number: CDU K 32 TF - 30 D - A93 L S
Explanation:

Series and Magnet

CU - Free-mount cylinder without a built-in magnet; omit magnetic-switch fields
CDU - Free-mount cylinder with a built-in magnet

Rod Configuration

Blank - Basic single rod; omit the configuration suffix
K - Non-rotating single rod
W - Double rod; standard-stroke double acting only
KW - Non-rotating double rod; standard-stroke double acting only

Bore

6 - 6mm
10 - 10mm
16 - 16mm
20 - 20mm
25 - 25mm
32 - 32mm

Port Thread

Blank - Metric thread for bores 6–25mm; Rc thread for 32mm bore; omit the thread suffix
TN - NPT thread; 32mm bore
TF - G thread; 32mm bore

Stroke

5, 10, 15, 20, 25, 30 - Standard double-acting strokes in mm for bores 6/10/16
5, 10, 15, 20, 25, 30, 40, 50 - Standard double-acting strokes in mm for bores 20/25/32
5, 10, 15 - Standard single-acting strokes in mm for all listed bores
40, 50, 60 - Long-stroke double acting for bores 6/10/16; exclude W/KW
60, 70, 80, 90, 100 - Long-stroke double acting for bores 20/25/32; exclude W/KW

Acting Type

D - Double acting
S - Single acting, spring return; basic or K configuration
T - Single acting, spring extend; basic or K configuration

Magnetic Switch

Blank - No switch; omit the switch code, preceding hyphen, lead-length code and quantity code
A93 - A93 switch
A96 - A96 switch
M9N - M9N switch
M9B - M9B switch
M9P - M9P switch
F9NW - F9NW switch

Switch Lead Length

Blank - 0.5m lead; omit the lead-length suffix
L - 3m lead
Z - 5m lead

Switch Quantity

Blank - Two switches; omit the quantity suffix
S - One switch

Description

CU free-mount cylinder configurations

CU cylinders provide pneumatic motion in a body designed for mounting on multiple faces. Select a standard or non-rotating rod, single or double rods, the required action and a magnetic-piston option before choosing bore and stroke.

Ordering fieldCodeSelection
MagnetBlank / DWithout / with built-in magnetic ring; CU / CDU family
Rod configurationBlankBasic single rod
Rod configurationKNon-rotating single rod
Rod configurationWDouble rod
Rod configurationKWNon-rotating double rod
Bore6, 10, 16, 20, 25, 32Bore in millimeters
Port thread, 6–25mm boreBlankM5×0.8
Port thread, 32mm boreBlank / TN / TFRc / NPT / G, 1/8 size
Stroke30Example: 30mm
ActionDDouble acting
ActionSSingle acting, spring return
ActionTSingle acting, spring extend
Magnetic switchBlank or selected modelNo switch or selected switch; requires built-in magnet
Switch quantityBlank / STwo / one

The example CDUK6□30D-A93□ specifies a magnetic, non-rotating cylinder with 6mm bore, 30mm stroke, double-acting operation and A93 switch; square placeholders indicate option positions. W and KW double-rod configurations are excluded from single-acting and long-stroke selections.

Operating specifications

ParameterSpecification
MediumAir
Maximum operating pressure0.7MPa
Ambient and air temperature without switch-10–70°C, nonfreezing
Ambient and air temperature with switch-10–60°C, nonfreezing
CushioningRubber cushions at both ends
Piston speed50–500mm/s
Stroke tolerance0 to +0.1mm
LubricationNot required
MountingFree mounting on multiple body faces

Minimum operating pressure by configuration

Values are in MPa. Match both action and rod configuration; a shared bore does not give all versions the same starting pressure.

ActionRod configuration6mm bore10–16mm bore20–32mm bore
Double actingStandard single rod0.120.060.05
Standard double rod, W0.150.100.08
Non-rotating single rod, K0.150.100.08
Non-rotating double rod, KW0.180.130.11
Single actingStandard single rod0.200.150.13
Non-rotating single rod, K0.230.180.16

Ports and non-rotating rod accuracy

BorePortNon-rotating rod accuracy
6mm, 10mm, 16mmM5×0.8±0.8°
20mm, 25mmM5×0.8±0.5°
32mm1/8, selected Rc/NPT/G thread±0.5°

The angular figures apply to non-rotating rod configurations, not to unrestricted rotation of a standard round rod.

Stroke and switch selection

Bore (mm)Standard stroke (mm)Long stroke, double acting (mm)Direct-mount switch choices
Double actingSingle acting
6, 10, 165, 10, 15, 20, 25, 305, 10, 1540, 50, 60A93, A96, M9N, M9B, M9P, F9NW
20, 25, 325, 10, 15, 20, 25, 30, 40, 5060, 70, 80, 90, 100

For spring-return operation, air extends the rod and the spring retracts it. For spring-extend operation, air retracts the rod and the spring extends it. Select magnetic switch model and quantity separately from the cylinder action and stroke.