CTE50 Economical LED Signal Towers with Fixed Color Stacks

Description

CTE50 economical signal towers combine one to five LED layers with optional audible indication. Select a fixed color stack, steady or flashing light operation, an appropriate supply version and one of four mounting arrangements.

The SMD LED construction uses prism-pattern PC lenses and an ABS base. High-brightness LED components have a typical life reference above 50,000 hours; this is a component reference rather than a complete-assembly service-life guarantee. Color combinations are fixed selections and cannot be freely rearranged.

Ordering Selections

FieldCodeMeaning and applicability
SeriesCTEEconomical multilayer warning light
Body size50Ø50mm nominal diameter
Fixed colorsROne red layer
RGTwo layers: red / green
RYGThree layers: red / yellow / green
RYGBFour layers: red / yellow / green / blue
RYGBWFive layers: red / yellow / green / blue / white
SoundOmittedNo sound
AIntermittent beep
BContinuous sound
Light modeWFlashing
TSteady
SSelectable flashing / steady; supplied set to steady
Supply voltageJ12VAC/DC
B24VAC/DC
M220VAC
FunctionOmittedRegular version, IP43 single-light protection
FIP65 version
KAnti-interference version
BaseADisc mounting
BSide-nut mounting
C90° square folding mount
D90° circular folding mount
Rod length10100mm
15150mm
26260mm
Other numberCustom rod length for the chosen mount
Cable lengthL060.6m
L1–L5L1 indicates1m; cable length is not limited to L5
ConnectionOmittedFree cable ends
M…M-type connector; complete connector details must be specified
D…DT-type connector; complete connector details must be specified
A…AMP-type connector; complete connector details must be specified
S…SM-type connector; complete connector details must be specified
Cable constructionOmittedPVC
UPUR sheathed cable
VPShielded PVC sheathed cable
UPShielded PUR sheathed cable
CTE50 model-code ordering diagram
Twelve ordering fields for the economical light stack and its mounting and cable configuration.

Common Models and Their Operating Codes

The following model patterns cover 120 common configurations. Replace [CODE] in any pattern with one complete code from the six-row operating table. Brackets and the word CODE are explanatory placeholders, not characters in an order number. Every listed configuration has a 0.6m cable and selectable flashing/steady light, initially set to steady.

Operating codeSoundLight operationSupply
SBNo soundSelectable flashing / steady; default steady24VAC/DC
ASBIntermittent beep
BSBContinuous sound
SMNo sound220VAC
ASMIntermittent beep
BSMContinuous sound
Model patternColor stackMountRod reference
CTE50-R/[CODE]-A10L06R; one layerDisc100mm
CTE50-R/[CODE]-B26L06Side nut260mm
CTE50-R/[CODE]-C10L06Square folding100mm
CTE50-R/[CODE]-DL06Circular foldingNo separate rod-length code
CTE50-RG/[CODE]-A10L06RG; two layersDisc100mm
CTE50-RG/[CODE]-B26L06Side nut260mm
CTE50-RG/[CODE]-C10L06Square folding100mm
CTE50-RG/[CODE]-DL06Circular foldingNo separate rod-length code
CTE50-RYG/[CODE]-A10L06RYG; three layersDisc100mm
CTE50-RYG/[CODE]-B26L06Side nut260mm
CTE50-RYG/[CODE]-C10L06Square folding100mm
CTE50-RYG/[CODE]-DL06Circular foldingNo separate rod-length code
CTE50-RYGB/[CODE]-A10L06RYGB; four layersDisc100mm
CTE50-RYGB/[CODE]-B26L06Side nut260mm
CTE50-RYGB/[CODE]-C10L06Square folding100mm
CTE50-RYGB/[CODE]-DL06Circular foldingNo separate rod-length code
CTE50-RYGBW/[CODE]-A10L06RYGBW; five layersDisc100mm
CTE50-RYGBW/[CODE]-B26L06Side nut260mm
CTE50-RYGBW/[CODE]-C10L06Square folding100mm
CTE50-RYGBW/[CODE]-DL06Circular foldingNo separate rod-length code

For example, CTE50-RYG/ASB-A10L06 is the three-layer disc-mounted 24VAC/DC model with intermittent sound. CTE50-RYGBW/BSM-DL06 is the five-layer circular-folding 220VAC model with continuous sound.

Electrical and LED References

Color12VDC24VDC220VAC
Maximum currentRounded DC powerMaximum currentRounded DC powerMaximum currentPower
Red32mA0.38W33mA0.79W53mA0.55W
Yellow27mA0.32W0.59W
Green19mA0.23W0.6W
Blue27mA0.32W0.7W
White34mA0.4W41mA0.98W51mA

These are color-channel references. DC power is calculated from nominal voltage and maximum current, then rounded. AC power and current remain separate specifications; complete-stack consumption depends on the selected configuration.

LED bead colorBead voltage
Red1.8–2.2V
Yellow
Green2.8–3.4V
Blue
White

The bead voltages describe individual LED components. Supply the assembled tower at its selected product voltage.

Operating Specifications

ParameterSpecification
Sound levelCTE50-A intermittent version: maximum85dB; test distance unspecified
Flashing rate55–65 flashes/min, nominal60 flashes/min
Lens / base materialPC / ABS
Cord specificationUL1007
Ambient temperature−30°C to +50°C
Relative humidity≤85%
ProtectionRegular single light: IP43; F version: IP65
Altitude≤2000m
Compliance referenceStandardDocument reference
CCCGB/T14048.5Document number not specified
CEEN61058

Light Stack Dimensions

Layers / colorsLight-body heightNominal diameter
1 / R105mm50mm
2 / RG159mm
3 / RYG213mm
4 / RYGB267mm
5 / RYGBW321mm

Heights refer to the light body and exclude the rod and base. Drawings below show all four mounting forms for each stack, with dimensions in mm.

CTE50 one-layer mounting outlines
One-layer side-nut, disc, square-folding and circular-folding configurations.
CTE50 two-layer mounting outlines
Two-layer configurations with the four mounting styles.
CTE50 three-layer mounting outlines
Three-layer configurations, including the square-folding version.
CTE50 four-layer mounting outlines
Four-layer configurations with the four mounting styles.
CTE50 five-layer mounting outlines
Five-layer configurations with the four mounting styles.
Mount / bracketDimensions in mm
A / CTL50-MADiscØ70; hole circleØ55; four Ø5 through holes withØ11 counterbores; rodØ18; bracket section90; installed base projection44.5
B / CTL50-MBSide-nut bracket32×78, inner width25; two Ø12 holes with22 center spacing and10 lower-edge reference; projection45; rod openingØ18; installed extension82
C / CTL50-MCSquare base72×72; four Ø6 holes on53×53 centers; height114; rodØ18
D / CTL50-MDCircular baseØ70; four Ø5 holes onØ55 circle; full bracket110; installed projection80; threaded section35; rodØ18
CTL50-MA MB MC MD brackets used with CTE50 towers
Mounting bracket outlines and fixing dimensions for the illustrated CTE50 configurations.

Wiring and Flashing Selection

Wire designationIllustrated function
R / redLayer1
Y / yellowLayer2
G / greenLayer3
B / blueLayer4
W / whiteLayer5
P / purpleBuzzer
GY / grayCommon line

Individual external contacts switch the layer and sound circuits. Follow the supply and polarity arrangement for the selected version. An open mode jumper selects flashing; a fitted link selects steady illumination.

CTE50 layer circuits buzzer and common-line wiring
Five-layer wiring reference with external contacts and the flashing/steady mode jumper.

Assembly, Orientation and Maintenance

Release a lens module by rotating counterclockwise to align the marks and pulling upward. Assemble it by aligning the marks, pressing downward and turning clockwise until the triangular mark reaches the index.

CTE50 modular lens release and locking
Module release and locking directions with alignment marks.

The cable outlet must not face upward. Install regular IP43 versions upright and vertical because their water protection is below IPX4. Use the hole pattern and fixing hardware for the chosen bracket, tighten the mounting and protect the wires against impact and abrasion.

CTE50 orientation reference and prohibited inverted installation
Installation orientation; regular IP43 versions require upright vertical mounting.

Disconnect the supply before installation, wiring, work on the assembly or maintenance. Verify the model and rated voltage, prevent conductive dust or liquid from entering, and have qualified personnel handle complex faults and high-voltage components.

Use these products for industrial signaling. High-reliability infrastructure, personal-safety functions, harsh environments, fire or explosion hazards, military uses and aerospace projects require a specifically designed and expressly confirmed configuration.