CSC Sensor and Actuator Cables

Description

Connector and Cable Selection

CSC cable assemblies connect sensors and actuators through M8×1 or M12×1 threaded connectors. Select female socket or male pin contacts, a straight or angled head and the required number of conductors. The common A-coded assemblies below have a connector at one end, free leads at the other and a 2m cable. PVC and PUR constructions are listed separately.

Common M8 Assemblies

Contact typeHeadCoresPVC modelPUR model
Female socketStraight3CSCM8-KIAV/3-L2CSCM8-KIAU/3-L2
4CSCM8-KIAV/4-L2CSCM8-KIAU/4-L2
5CSCM8-KIAV/5-L2CSCM8-KIAU/5-L2
Angled3CSCM8-KLAV/3-L2CSCM8-KLAU/3-L2
4CSCM8-KLAV/4-L2CSCM8-KLAU/4-L2
5CSCM8-KLAV/5-L2CSCM8-KLAU/5-L2
Male pinStraight3CSCM8-ZIAV/3-L2CSCM8-ZIAU/3-L2
4CSCM8-ZIAV/4-L2CSCM8-ZIAU/4-L2
5CSCM8-ZIAV/5-L2CSCM8-ZIAU/5-L2
Angled3CSCM8-ZLAV/3-L2CSCM8-ZLAU/3-L2
4CSCM8-ZLAV/4-L2CSCM8-ZLAU/4-L2
5CSCM8-ZLAV/5-L2CSCM8-ZLAU/5-L2

Common M12 Assemblies

Contact typeHeadCoresPVC modelPUR model
Female socketStraight3CSCM12-KIAV/3-L2CSCM12-KIAU/3-L2
4CSCM12-KIAV/4-L2CSCM12-KIAU/4-L2
5CSCM12-KIAV/5-L2CSCM12-KIAU/5-L2
Angled3CSCM12-KLAV/3-L2CSCM12-KLAU/3-L2
4CSCM12-KLAV/4-L2CSCM12-KLAU/4-L2
5CSCM12-KLAV/5-L2CSCM12-KLAU/5-L2
Male pinStraight3CSCM12-ZIAV/3-L2CSCM12-ZIAU/3-L2
4CSCM12-ZIAV/4-L2CSCM12-ZIAU/4-L2
5CSCM12-ZIAV/5-L2CSCM12-ZIAU/5-L2
Angled3CSCM12-ZLAV/3-L2CSCM12-ZLAU/3-L2
4CSCM12-ZLAV/4-L2CSCM12-ZLAU/4-L2
5CSCM12-ZLAV/5-L2CSCM12-ZLAU/5-L2

Ordering Positions and Options

CSC cable ordering layout with twelve numbered selection positions
Match the numbered positions to the connector, cable and length selections below.
PositionSelectionCodeMeaning
1SeriesCSCSensor and actuator cable
2Threaded connectionM12M12×1
M8M8×1
3Product versionOmittedStandard
EEconomy version
4ContactsKFemale sockets
ZMale pins
5Head formIStraight
LAngled
6Connector codingAA-coded
BB-coded
DD-coded
7Cable materialVPVC
UPUR
8ShieldingOmittedUnshielded
PShielded
9Conductors3Three cores
4Four cores
5Five cores
10IndicatorOmittedWithout light
DWith light
11Output-mode matchingNNPN configuration
PPNP configuration
12LengthL1-L5L1 = 1m, through L5 = 5m; other cable lengths can be specified

The common-model tables identify the standard A-coded, unshielded, unlit 2m assemblies. Select other coding, shielding, indicator and NPN/PNP configurations as a complete compatible combination. Match the connector coding, contact count and pin assignment to the connected equipment.

Protection and Documentation

The range is marked IP67 in the selection guide. Check the protection requirements of the complete mated connection for the installation. The guide also displays CE, RoHS and ISO 9001 quality-system marks; obtain the relevant documentation for the required assembly.