CM-1N PA66 Horizontal Limit Switches

Series Part Number

Part Number: CM-1 703M N
Explanation:

Series

CM-1 - Standard horizontal limit switch family

Actuator

701 - Long lever
702 - Short lever
703 - Roller lever
703M - Metal roller lever
704 - Short roller lever
704M - Short metal roller lever
705 - Wire lever
706 - Curved lever
306 - Short spring plunger
307 - Panel-mount plunger
308 - Panel-mount vertical roller plunger
309 - Panel-mount transverse roller plunger
308X - Panel-mount small vertical roller plunger
713 - Large plastic roller long lever
743 - One-way short roller lever
743M - One-way short metal roller lever
300 - Pin plunger
301 - Leaf spring
303 - Roller leaf spring
303M - Metal roller leaf spring
305 - Slim spring plunger

Housing

N - PA66 engineering plastic housing

Description

PA66 switches for mechanical position control

CM-1N horizontal limit switches combine a PA66 engineering plastic housing with snap-action 1NO+1NC contacts. Twenty-one actuator configurations include lever, roller, wire, leaf-spring and plunger mechanisms. Select the head for the target approach and available movement, then check its force, pretravel, overtravel and operating-position tolerances.

Ordering-code structure

CM-1703MN combines the fixed series identifier CM-1, actuator code 703M and housing suffix N. Here N specifies PA66. M remains part of the complete metal-roller actuator code; X remains part of code 308X. Every model below uses snap-action 1NO+1NC contacts with common COM, normally closed NC and normally open NO functions.

ModelHead codeActuator
CM-1701N701Long lever
CM-1702N702Short lever
CM-1703N703Roller lever
CM-1703MN703MMetal roller lever
CM-1704N704Short roller lever
CM-1704MN704MShort metal roller lever
CM-1705N705Wire lever
CM-1706N706Curved lever
CM-1306N306Short spring plunger
CM-1307N307Panel-mount plunger
CM-1308N308Panel-mount vertical roller plunger
CM-1309N309Panel-mount transverse roller plunger
CM-1308XN308XPanel-mount small vertical roller plunger
CM-1713N713Large plastic roller long lever
CM-1743N743One-way short roller lever
CM-1743MN743MOne-way short metal roller lever
CM-1300N300Pin plunger
CM-1301N301Leaf spring
CM-1303N303Roller leaf spring
CM-1303MN303MMetal roller leaf spring
CM-1305N305Slim spring plunger

Electrical and environmental characteristics

ParameterValue and condition
Housing / contact formPA66; 1NO+1NC snap action
Operating speed0.05mm/s-1m/s, plunger type
Electrical operating frequency20 operations/min
Initial contact resistance25mΩ maximum
Insulation resistance100MΩ minimum at 500VDC
Minimum applicable load24VDC, 10mA
Rated insulation voltage Ui380V
Rated impulse withstand voltage Uimp4kV
Conventional free-air thermal current Ith15A
Vibration1.5mm amplitude at 10-20Hz; malfunction durability range 10-55Hz
Shock, mechanical durability1000m/s²
Shock, malfunction300m/s²
Ambient temperature-20°C to +80°C, without icing
Humidity, general type85%RH maximum
Humidity, separately specified sealed type95%RH maximum; not a sealing designation for standard models
Dielectric test locationVoltageDuration / frequency
Between terminals of the same polarity1000VAC1 minute, 50/60Hz
Between current-carrying and non-current-carrying metal parts1500VAC
Between each terminal and ground
Electrical enduranceResistive-load condition
More than 500,000 cycles240VAC, 3A
More than 200,000 cycles240VAC, 10A
More than 300,000 cycles250VAC, 15A

Endurance values apply to their stated loads. Confirm service life under the actual speed, operating frequency and electrical duty. Standard CM-1N switches are not waterproof sealed devices; provide external protection against splash, dust and cutting chips.

Load-specific current ratings

All currents are amperes. Shared cells apply to both NC and NO, while lamp and motor ratings distinguish the contact where shown. NC30A and NO15A inrush limits apply to all eight voltage rows. The 30VDC resistive designation is 6(2)A; confirm the applicability of the parenthetical rating before selecting that duty.

VoltageNoninductive loadInductive loadInrush maximum
ResistiveLampInductiveMotor
NCNONCNONCNONCNONCNO
125VAC1531.51552.53015
250VAC2.51.2531.5
500VAC31.50.752.51.50.75
8VDC1531.51552.5
14VDC10
30VDC6(2)5
125VDC0.40.40.40.050.050.05
250VDC0.20.20.20.030.030.03
CM-1N current ratings for resistive, lamp, inductive and motor loads with NC and NO inrush limits
Switching-current and inrush limits by voltage and contact.

Actuator force and movement

OF is maximum operating force, RF minimum release force, PT maximum pretravel, OT minimum overtravel, MD maximum differential travel and FP maximum free position. OP is the operating-position datum. A dash means the value is not specified. Observe the intended approach direction for one-way roller heads.

ModelOFRFPTOTMDFPOP
CM-1701N0.7N0.14N10mm5.6mm1.27mm28.2mm19±0.8mm
CM-1702N1.6N0.28N5mm2mm1mm24.8mm19±0.4mm
CM-1703N1N0.22N7.1mm4mm1.02mm36.5mm30.2±0.8mm
CM-1703MN
CM-1704N1.6N0.42N2.7mm2.4mm0.5mm32.5mm30.2±0.4mm
CM-1704MN
CM-1705N0.1N0.03N20mm5.6mm3mm—19±0.8mm
CM-1706N0.7N0.14N10mm5.6mm1.27mm42mm37.2±0.8mm
CM-1306N3.5N1.14N0.4mm1.6mm0.05mm—21.5±0.5mm
CM-1307N5.5mm21.8±0.8mm
CM-1308N3.58mm33.4±1.2mm
CM-1309N
CM-1308XN
CM-1713N1N0.2N7.1mm4mm1.6mm47.5mm41.2±0.8mm
CM-1743N1.6N0.42N2.7mm2.4mm0.5mm43.6mm43.1±0.8mm
CM-1743MN
CM-1300N3.5N1.14N0.4mm0.13mm0.05mm—15.9±0.4mm
CM-1301N3N0.5N4mm1.6mm1.3mm20.6mm17.4±0.8mm
CM-1303N31.8mm28.6±0.8mm
CM-1303MN
CM-1305N3.5N1.14N0.4mm1.6mm0.05mm—28.2±0.5mm

TF denotes total-travel force, RP release position, TTP total-travel position and TT total travel. Set movement beyond the operating point to 70-100% of the specified OT. Avoid exceeding overtravel, abrupt impact or operation outside the specified speed and frequency ranges.

Mounting dimensions and installation

The body drawings show 49.6mm length and 25.4±0.1mm mounting centers. Width and mounting-hole geometry depend on the construction; use the outline for the exact model. Lever radii are R63.5mm for CM-1701N, R28.2mm for CM-1702N, R48.5mm for CM-1703N/1703MN and R26.6mm for CM-1704N/1704MN. Roller levers use Ø9.5×4mm rollers. CM-1713N uses a Ø20×4mm plastic roller, and CM-1705N has a Ø1mm wire lever with R155mm geometry.

Panel plungers use M12×1 threads. CM-1308N and CM-1309N have Ø12.7×3.8mm rollers in vertical and transverse orientations, respectively; CM-1308XN is the small vertical roller type. Plunger diameters are Ø2.3mm for CM-1300N, Ø4mm for CM-1305N and Ø7.3mm for CM-1306N.

Installation itemRequirement
Body mountingM4 screws, flat and spring washers; 1.18-1.47N·m
Panel actuator hex nut2.94-4.9N·m
Plunger panel cutoutØ12.5mm, +0.2/0 tolerance
Roller-plunger panel cutoutKeyed outline, Ø12.5mm with 13mm by 5mm geometry; use the complete drawing

For side-screw mounting of CM-1307N, CM-1308N and CM-1309N, remove the actuator hex nut and avoid excessive cam angle, speed or shock above 1000m/s². Install away from chip accumulation and provide a guard where accidental operation is possible. Mount in a direction and location that avoid resonance.

Wiring and small-load service

Turn power off before installation, wiring, removal or maintenance. Use insulated M3.5 crimp terminals with AWG20-AWG18 or 0.5-0.75mm² conductors. Keep terminal thickness within 0.5mm and fit each terminal flat without interference with the housing or cover. Exclude wire fragments from the mechanism.

Crimp-terminal dimensionValue
Thickness t0.5mm maximum
Hole diameter Ødz3.7mm
Barrel diameter ØD2.9mm
Width B6.6mm
Length L19mm
F7.7mm
I8mm
Cable typeCoresConductorFinished outside diameter
Plastic/rubber-insulated flexible cable2, 3 or 40.5-0.75mm²Round, Ø6-9mm
600V plastic-insulated, plastic-sheathed cable2Ø1mm, Ø1.2mm or Ø1.6mm

For solder connections, use an iron no greater than 60W, with heating limited to 5 seconds at 350°C or 3 seconds at 380°C. Avoid prolonged heating and incomplete joints. For signals below 24VDC/10mA or prolonged low-frequency use, specify suitable low-load contacts. Do not reassign contacts from general loads to small signals. Use suitable RC suppression and contact protection against bounce, noise and impulse currents.

Referenced standards and service limits

DesignationReferenced standardDocumentation
CCCGB/T 14048.5Request documentation applicable to the ordered model
TUVEN 60947-5-1
CE
Utilization categoryOperational rating
AC-1515A at 250VAC
DC-130.3A at 220VDC

Keep oil, water, corrosive gases and volatile silicone materials away from the contacts. Avoid steam, hot water above 60°C, rapid thermal changes and outdoor conditions beyond the stated limits. Personnel protection, high-reliability infrastructure, nuclear, fire or explosion hazards, harsh chemical environments, military and aerospace use require a separately specified design and application approval.