| Part Number: | CM-1 | 703M | K |
|---|---|---|---|
| Explanation: |
Series CM-1 - Standard horizontal limit switch family |
Actuator 701 - Long lever |
Protection K - Terminal protective cover and tail sleeve version with phenolic molding compound body; not a waterproof enclosure |
CM-1K horizontal limit switches use 1NC/1NO snap-action contacts in a phenolic molding compound body with a terminal cover and tail sleeve. The actuator range includes straight and curved levers, plastic and metal rollers, one-way levers, leaf springs and several plunger geometries. Choose the operating force and travel together with the cam approach and available installation space.
The K cover protects the terminal area but does not make the switch waterproof. Provide suitable external protection from water, oil, chips and dust. These models are distinct from the plain-body CM-1 and other suffix versions.
CM-1703MK is assembled as CM-1 + 703M + K: standard family, metal roller lever and K terminal protection. There is no separator between these three segments. The hyphen is part of the fixed CM-1 family identifier. Use each complete actuator code, including M or X where present.
| Segment | Code | Selection |
|---|---|---|
| Series | CM-1 | Standard horizontal limit switch family |
| Actuator | 701 / 702 | Long / short lever |
| 703 / 703M | Roller / metal roller lever | |
| 704 / 704M | Short roller / short metal roller lever | |
| 705 | Wire lever | |
| 706 | Curved lever | |
| 306 | Short spring plunger | |
| 307 | Panel-mount plunger | |
| 308 | Panel-mount roller plunger | |
| 309 | Panel-mount lateral roller plunger | |
| 308X | Small vertical roller plunger | |
| 713 | Long lever with large plastic roller | |
| 743 / 743M | One-way short roller / short metal roller lever | |
| 300 | Needle plunger | |
| 301 | Leaf spring | |
| 303 | Roller leaf spring | |
| 303M | Metal roller leaf spring | |
| 305 | Thin spring plunger | |
| Protection | K | Terminal cover and tail sleeve with phenolic body |
All listed models have 1NC/1NO snap-action contacts. OF is maximum operating force, RF minimum release force, PT maximum pretravel, OT minimum available overtravel, MD maximum movement differential, FP maximum free position and OP operating position. A dash means the value is not specified. Dimensions are referenced to the datums in the attached model drawings.
| Model and actuator | OF | RF | PT | OT | MD | FP | OP |
|---|---|---|---|---|---|---|---|
| CM-1701K long lever | 0.7N | 0.14N | 10mm | 5.6mm | 1.27mm | 28.2mm | 19±0.8mm |
| CM-1702K short lever | 1.6N | 0.28N | 5mm | 2mm | 1mm | 24.8mm | 19±0.4mm |
| CM-1703K roller lever | 1N | 0.22N | 7.1mm | 4mm | 1.02mm | 36.5mm | 30.2±0.8mm |
| CM-1703MK metal roller lever | |||||||
| CM-1704K short roller lever | 1.6N | 0.42N | 2.7mm | 2.4mm | 0.5mm | 32.5mm | 30.2±0.4mm |
| CM-1704MK short metal roller lever | |||||||
| CM-1705K wire lever | 0.1N | 0.03N | 20mm | 5.6mm | 3mm | — | 19±0.8mm |
| CM-1706K curved lever | 0.7N | 0.14N | 10mm | 5.6mm | 1.27mm | 42mm | 37.2±0.8mm |
| CM-1713K large plastic roller lever | 1N | 0.2N | 7.1mm | 4mm | 1.6mm | 47.5mm | 41.2±0.8mm |
| CM-1743K one-way roller lever | 1.6N | 0.42N | 2.7mm | 2.4mm | 0.5mm | 43.6mm | 43.1±0.8mm |
| CM-1743MK one-way metal roller lever |
| Model and actuator | OF | RF | PT | OT | MD | FP | OP |
|---|---|---|---|---|---|---|---|
| CM-1300K needle plunger | 3.5N | 1.14N | 0.4mm | 0.13mm | 0.05mm | — | 15.9±0.4mm |
| CM-1305K thin spring plunger | 1.6mm | 28.2±0.5mm | |||||
| CM-1306K short spring plunger | 21.5±0.5mm | ||||||
| CM-1307K panel-mount plunger | 5.5mm | 21.8±0.8mm | |||||
| CM-1308K panel-mount roller plunger | 3.5mm | 33.4±1.2mm | |||||
| CM-1309K panel-mount lateral roller plunger | |||||||
| CM-1308XK small vertical roller plunger |
| Model and actuator | OF | RF | PT | OT | MD | FP | OP |
|---|---|---|---|---|---|---|---|
| CM-1301K leaf spring | 1.5N | 0.14N | 4mm | 1.6mm | 1.3mm | 20.6mm | 17.4±0.8mm |
| CM-1303K roller leaf spring | 31.8mm | 28.6±0.8mm | |||||
| CM-1303MK metal roller leaf spring |
The needle plunger has only 0.13mm minimum overtravel, so its stop setting needs particular care. Set working overtravel to 70–100% of the rated OT without exceeding the permitted movement. One-way roller assemblies have the illustrated 90° roller swing; this is distinct from the linear PT and OT values.
| Parameter | Value or condition |
|---|---|
| Rated operating load, AC-15 | 15A at 250VAC |
| Rated operating load, DC-13 | 0.3A at 220VDC |
| Rated insulation voltage Ui | 380V |
| Rated impulse withstand voltage Uimp | 4kV |
| Conventional thermal current Ith | 15A |
| Operating speed, plunger type | 0.05mm/s–1m/s |
| Electrical operating frequency | 20 operations/min |
| Initial contact resistance | 25mΩ maximum |
| Insulation resistance | 100MΩ minimum at 500VDC |
| Minimum standard-contact load | 24VDC, 10mA |
| Dielectric strength, same-polarity terminals | 1000VAC, 50/60Hz, 1 minute |
| Dielectric strength, current-carrying to non-current-carrying metal | 1500VAC, 50/60Hz, 1 minute |
| Dielectric strength, terminals to ground | 1500VAC, 50/60Hz, 1 minute |
| Vibration reference | 1.5mm amplitude; frequency entries 10–20Hz and 10–55Hz do not define a single qualified test sweep |
| Shock resistance | Mechanical durability: 1000m/s²; malfunction: 300m/s² |
| Ambient temperature | -20°C to +80°C, without icing |
| Ambient humidity, general-purpose type | Below 85%RH |
| Conditional sealed-type humidity | 95%RH maximum only for an explicitly specified sealed type; the K sleeve alone does not establish this condition |
| Ingress protection | No waterproof rating specified for this K construction |
| Resistive test load | Electrical endurance |
|---|---|
| 240VAC, 3A | More than 500,000 cycles |
| 240VAC, 10A | More than 200,000 cycles |
| 250VAC, 15A | More than 300,000 cycles |
These endurance values belong to their stated test loads and cannot be used as one uniform life rating. Verify life under the actual cam speed, switching frequency and load. Very slow actuation can produce unstable switching; excessive speed or frequency can cause impact damage or poor contact follow-up.
| Specification reference | Standard |
|---|---|
| CCC | GB/T 14048.5 |
| TUV | EN 60947-5-1 |
| CE |
Use the applicable model-specific certification documents when approval is required. Specification references and component markings do not establish certification of a complete machine.
| Voltage | Non-inductive load | Inductive load group | Maximum inrush | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Resistive | Lamp | Inductive | Motor | |||||||
| NC | NO | NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC | 15A | 3A | 1.5A | 15A | 5A | 2.5A | 30A | 15A | ||
| 250VAC | 2.5A | 1.25A | 3A | 1.5A | ||||||
| 500VAC | 3A | 1.5A | 0.75A | 2.5A | 1.5A | 0.75A | ||||
| 8VDC | 15A | 3A | 1.5A | 15A | 5A | 2.5A | ||||
| 14VDC | 10A | |||||||||
| 30VDC | 6(2)A | 5A | ||||||||
| 125VDC | 0.4A | 0.4A | 0.4A | 0.05A | 0.05A | 0.05A | ||||
| 250VDC | 0.2A | 0.2A | 0.2A | 0.03A | 0.03A | 0.03A | ||||
The 30VDC resistive entry is specified as 6(2)A; the condition represented by parentheses is not defined, so confirm applicability before selecting this duty. The 500VAC general-load entry does not increase the stated 380V insulation rating or authorize operation above the selected model's insulation and approval limits. Apply the contact, load, utilization-category and insulation limits together.

Use the full model drawings to select the actuator and mounting datum. Some drawings dimension the bare switch body at 49.6×17.6mm; the covered construction is also shown with a 52.8mm housing length, an additional 15.5mm sleeve projection and 18.7mm overall width. These measurements refer to different parts of the assembly.
| Feature | Dimension or requirement |
|---|---|
| Body mounting | Two M4 screws with flat and spring washers; 25.4±0.1mm centers |
| Body screw torque | 1.18–1.47N·m |
| Panel plunger thread | M12×1 |
| Panel nut torque | 2.94–4.9N·m |
| Panel mounting hole | Ø12.5mm, +0.2/0 tolerance |
| Roller-plunger keyed panel cutout | 13mm and 5mm reference dimensions, each +0.2/0; follow the cutout drawing |
| CM-1308K / CM-1309K roller | Stainless steel, Ø12.6×3.8mm |
| CM-1308XK roller | Stainless steel, Ø10×3.8mm |
| CM-1713K large roller | Plastic, Ø20×4mm |
| CM-1300K needle | Ø2.4mm |
| CM-1306K short plunger | Ø7.5mm |
| CM-1305K thin plunger | Ø4mm stem with Ø5mm tip |
For side-screw mounting of the panel-plunger models, remove the actuator hex nut as indicated, avoid excessive cam angles and speed, and do not apply shock exceeding 1000m/s². Install a cover where accidental actuation is possible. Keep the switch away from resonant vibration and provide a separate stop so the cam cannot overdrive the actuator.
Turn off power before installation, wiring or maintenance. Size wiring for the applied current and voltage. Where solder terminals are used, use an iron of at most 60W and limit heating to 350°C for 5s or 380°C for 3s. Avoid prolonged heating and incomplete joints.
For the specified M3.5 crimp-terminal arrangement, use insulated terminals with 0.5–0.75mm² conductors, approximately AWG20–AWG18. Keep terminals clear of the body and cover, use suitable wire lengths and remove all cut wire fragments before closing.
| Crimp terminal dimension | Value |
|---|---|
| Thickness | 0.5mm maximum |
| Stud hole diameter | 3.7mm |
| Barrel diameter | 2.9mm |
| Width B | 6.6mm |
| Length L | 19mm |
| F / l | 7.7mm / 8mm |
| Cable type | Cores | Conductor | Overall diameter |
|---|---|---|---|
| Plastic or rubber insulated flexible cable | 2, 3 or 4 | 0.5–0.75mm² | Circular, Ø6–9mm |
| 600V plastic insulated, plastic sheathed VVF | 2 | Ø1mm, Ø1.2mm or Ø1.6mm |
Prevent chips and dust from accumulating on the body or actuator. Shield the switch from oil, water spray, hot water above 60°C and steam. Avoid outdoor exposure, abrupt temperature changes, corrosive gases and silicone-containing materials that can form insulating deposits on contacts. This switch is not specified for unprotected operation in flammable or explosive atmospheres.
For prolonged low-current or infrequent switching, select a contact design intended for the signal level, such as an appropriate gold-contact version. Standard contacts require at least 24VDC and 10mA; below this level, current may not break through surface films. Do not reuse contacts previously operated at general loads for smaller-capacity signal circuits. Apply suitable suppression to loads that create inrush or contact arcing.
Exceptional reliability, personal safety protection, severe environments, aerospace and military applications require an expressly assessed design. Confirm the selected model's mechanical operation and electrical endurance under the actual installation conditions.