CJY-S/M Long Range Inductive Sensors with M12 Connectors

Description

CNTD CJY-S/M long range cylindrical inductive sensors provide 4–30mm nominal metal-detection distances with a straight male M12 four-pin A-coded connector. Flush and nonflush sensing housings in M12, M18 and M30 sizes have nickel-plated brass construction, red operating indicators and IP65 protection. The manufacturer describes nominal sensing distances approximately 1.5–2 times those of its existing standard models; select the actual operating gap from the specified setting range.

Model and Output Choices

All listed models operate at 10–30VDC. DNA/DNB identify NPN NO/NC; DPA/DPB identify PNP NO/NC. DNC/DPC provide complementary NO+NC outputs. The attachment gives single-output circuit and connector diagrams; it does not assign both output conductors of a NO+NC version.

Sensing housing / distanceNPN modelsPNP models
M12 / 4mm, flushCJY12S-04DNA/M
CJY12S-04DNB/M
CJY12S-04DNC/M
CJY12S-04DPA/M
CJY12S-04DPB/M
CJY12S-04DPC/M
M12 / 8mm, nonflushCJY12S-08DNA/M
CJY12S-08DNB/M
CJY12S-08DNC/M
CJY12S-08DPA/M
CJY12S-08DPB/M
CJY12S-08DPC/M
M18 / 10mm, flushCJY18S-10DNA/M
CJY18S-10DNB/M
CJY18S-10DNC/M
CJY18S-10DPA/M
CJY18S-10DPB/M
CJY18S-10DPC/M
M18 / 16mm, nonflushCJY18S-16DNA/M
CJY18S-16DNB/M
CJY18S-16DNC/M
CJY18S-16DPA/M
CJY18S-16DPB/M
CJY18S-16DPC/M
M30 / 20mm, flushCJY30S-20DNA/M
CJY30S-20DNB/M
CJY30S-20DNC/M
CJY30S-20DPA/M
CJY30S-20DPB/M
CJY30S-20DPC/M
M30 / 30mm, nonflushCJY30S-30DNA/M
CJY30S-30DNB/M
CJY30S-30DNC/M
CJY30S-30DPA/M
CJY30S-30DPB/M
CJY30S-30DPC/M

Setting Ranges and Response Frequency

Model groupNominal distanceSetting rangeStandard iron targetAverage response frequency
CJY12S-04/M4mm0–2.8mm12×12×1mm400Hz
CJY12S-08/M8mm0–4.9mm25×25×1mm300Hz
CJY18S-10/M10mm0–7mm20×20×1mm
CJY18S-16/M16mm0–10.5mm40×40×1mm200Hz
CJY30S-20/M20mm0–11.9mm45×45×1mm100Hz
CJY30S-30/M30mm0–17.5mm75×75×1mm

Use each setting-range entry directly rather than calculating one common percentage of nominal distance. Response frequency is an average measured with the standard target, twice the target width as the spacing between successive targets, and a sensing gap equal to half the nominal distance.

Electrical and Environmental Specifications

ParameterRating for the listed models
Supply / maximum control output10–30VDC / 200mA
Leakage current / residual voltage≤10mA / ≤1V
Hysteresis≤10% of nominal detection distance
Temperature influenceWithin ±10% of the sensing distance at 20°C over −25 to +70°C
Protection circuitSurge, reverse-polarity and overcurrent protection
Enclosure / indicationIP65; red operating LED
Operating / storage temperature−25 to +70°C / −30 to +80°C, without icing
Humidity35–95%RH, without condensation
Insulation resistance≥50MΩ at 500VDC
Dielectric strength1500VAC, 50/60Hz, 1min
Vibration1mm amplitude, 10–55Hz swept over 1min, 2h per X/Y/Z direction
Shock500m/s², approximately 50G, three times per X/Y/Z direction
MaterialsNickel-plated brass case and nuts; nickel-plated iron washers; PBT sensing face

Ordering Code Layout

Ten numbered positions in a CJY-S/M long range connector inductive sensor code
CJY-S/M ordering code with the S long range field and direct M12 connector suffix.
PositionElementMeaning and options
1CJInductive sensing
2Housing shapeY=cylindrical metal. YG=stainless-steel cylindrical housing and YS=plastic cylindrical housing are additional general guide choices; listed full models use Y.
3Size12=M12, 18=M18, 30=M30 in the model selection. The guide also identifies 08=M8, without a corresponding full model here.
4SLong range type
5Thread lengthBlank=standard; L=long thread. The illustrated dimensions apply to standard bodies.
6Distance04=4mm, 08=8mm, 10=10mm, 16=16mm, 20=20mm, 30=30mm for listed models; 02=2mm also appears in the general guide.
7SupplyD=10–30VDC for the full models above; A=90–250VAC and E=20–60VDC are general guide options without full models in this selection.
8OutputN=NPN; P=PNP
9StateA=NO; B=NC; C=NO+NC
10MStraight male M12 four-pin A-coded connector, after the slash in the complete designation

Pin Assignments and Connector Installation

Single-output circuitSupply pinsOutput pinLoad connection
NPNPin 1: brown / +V; pin 3: blue / 0VPin 4: black / switching outputBetween +V and pin 4
PNPBetween pin 4 and 0V

Pin 2 is not assigned by the illustrated single-output diagrams. Use the connector-face and timing drawings in the attachment for orientation and NO/NC behavior. NO+NC versions require their matching output assignment; the single-output drawing is not a complete pinout for them. Tighten the connector to 0.39–0.49N·m and secure the cable connection with tape where vibration occurs. A fixed cordset length is not specified for these direct-connector sensor bodies.

Housing Dimensions

Housing / mountingSensing threadOverall axial referenceThread referenceFront projectionNut reference
CJY12S-04/M, flushM12×165mm50mmFlushØ21mm, 17mm across flats, 4mm thick
CJY12S-08/M, nonflush60mm45mm7mm
CJY18S-10/M, flushM18×165mm50mmFlushØ29mm, 24mm across flats, 4mm thick
CJY18S-16/M, nonflush60mm45mm10mm
CJY30S-20/M, flushM30×1.565mm50mmFlushØ41mm, 36mm across flats, 5mm thick
CJY30S-30/M, nonflush60mm45mm11mmØ41mm, 35mm across flats as drawn, 5mm thick

The rear electrical connector thread is M12×1 on all illustrated housings. Axial dimensions follow the drawing endpoints and include the illustrated connector body, without a separate cable assembly. Complete indicator, nut and sensing-head geometry is retained in the attachment.

Spacing and Surrounding-Metal Clearances

All values below are millimeters. A and B are the illustrated face-to-face and parallel spacing. n is the sensing-head exposure reference; Ød is the surrounding-metal opening diameter; ℓ and m follow the axial and surrounding-metal endpoints in the attached geometry.

Model groupABnØdℓm
CJY12S-04/M24240121218
CJY12S-08/M483611362436
CJY18S-10/M42360182127
CJY18S-16/M845414544254
CJY30S-20/M90600304545
CJY30S-30/M1509015907590

Standards and Application Conditions

The guide references CCC to GB/T14048.10 and TÜV/CE to EN60947-5-2; supporting certification documents are not included. Utilization references are DC-13 at 10–30VDC, 200mA and AC-140 at 24–250VAC, 200mA. The AC reference does not change the 10–30VDC operating supply of the listed models.

Use for ordinary industrial metal-position sensing within the specified target, gap, circuit and mounting conditions. Regional versions can differ. The manufacturer excludes personnel-safety functions, exceptionally high-reliability nuclear, gas and power systems, harsh outdoor or contaminated environments, fire or explosion hazards, strong acids or alkalis, and military or aerospace applications unless specifically designed and confirmed for that purpose.