CJY-E Economy Cylindrical Inductive Proximity Sensors

Description

CNTD CJY-E economy cylindrical inductive proximity sensors detect metal targets without mechanical contact. The range combines nickel-plated brass housings, red operating indicators and IP67 protection, with nominal detection distances from 1mm to 15mm. Choose the sensing head and installation clearance first, then match the output circuit and supply voltage to the control input.

DC Three-Wire Model Selection

All models below use 10–30VDC. DNA is NPN normally open, DNB is NPN normally closed, DPA is PNP normally open and DPB is PNP normally closed. DNC and DPC provide complementary NO+NC outputs and require four conductors. Combined outputs are listed for the M12, M18 and M30 groups only.

Size / distance groupNPN modelsPNP models
04E / 1mmCJY04E-01DNA
CJY04E-01DNB
CJY04E-01DPA
CJY04E-01DPB
05E / 1mmCJY05E-01DNA
CJY05E-01DNB
CJY05E-01DPA
CJY05E-01DPB
06E / 1mmCJY06E-01DNA
CJY06E-01DNB
CJY06E-01DPA
CJY06E-01DPB
6.5E / 1.5mmCJY6.5E-1.5DNA
CJY6.5E-1.5DNB
CJY6.5E-1.5DPA
CJY6.5E-1.5DPB
08E / 1mm, flushCJY08E-01DNA
CJY08E-01DNB
CJY08E-01DPA
CJY08E-01DPB
08E / 2mm, nonflushCJY08E-02DNA
CJY08E-02DNB
CJY08E-02DPA
CJY08E-02DPB
12E / 2mm, flushCJY12E-02DNA
CJY12E-02DNB
CJY12E-02DNC
CJY12E-02DPA
CJY12E-02DPB
CJY12E-02DPC
12E / 4mm, nonflushCJY12E-04DNA
CJY12E-04DNB
CJY12E-04DNC
CJY12E-04DPA
CJY12E-04DPB
CJY12E-04DPC
18E / 5mm, flushCJY18E-05DNA
CJY18E-05DNB
CJY18E-05DNC
CJY18E-05DPA
CJY18E-05DPB
CJY18E-05DPC
18E / 8mm, nonflushCJY18E-08DNA
CJY18E-08DNB
CJY18E-08DNC
CJY18E-08DPA
CJY18E-08DPB
CJY18E-08DPC
30E / 10mm, flushCJY30E-10DNA
CJY30E-10DNB
CJY30E-10DNC
CJY30E-10DPA
CJY30E-10DPB
CJY30E-10DPC
30E / 15mm, nonflushCJY30E-15DNA
CJY30E-15DNB
CJY30E-15DNC
CJY30E-15DPA
CJY30E-15DPB
CJY30E-15DPC

Two-Wire Model Selection

Head / sensing distanceDC normally open / normally closedAC normally open / normally closed
M8 / 1mmCJY08E-01DLA
CJY08E-01DLB
No model listed
M8 / 2mmCJY08E-02DLA
CJY08E-02DLB
No model listed
M12 / 2mmCJY12E-02DLA
CJY12E-02DLB
No model listed
M12 / 4mmCJY12E-04DLA
CJY12E-04DLB
CJY12E-04AKA
CJY12E-04AKB
M18 / 5mmCJY18E-05DLA
CJY18E-05DLB
CJY18E-05AKA
CJY18E-05AKB
M18 / 8mmCJY18E-08DLA
CJY18E-08DLB
CJY18E-08AKA
CJY18E-08AKB
M30 / 10mmCJY30E-10DLA
CJY30E-10DLB
CJY30E-10AKA
CJY30E-10AKB
M30 / 15mmCJY30E-15DLA
CJY30E-15DLB
CJY30E-15AKA
CJY30E-15AKB

Sensing Range and Response

Size / distance codeNominal sensing distanceSetting distanceStandard iron targetDC response frequency
04E-011mm0–0.8mm6×6×1mm1500Hz
05E-017×7×1mm
06E-018×8×1mm1000Hz
6.5E-1.51.5mm0–1.05mm8×8×1.5mm
08E-011mm0–0.8mm8×8×1mm
08E-022mm0–1.4mm
12E-022mm0–1.4mm12×12×1mm1000Hz
12E-044mm0–2.8mm500Hz
18E-055mm0–3.5mm18×18×1mm350Hz
18E-088mm0–5.6mm25×25×1mm
30E-1010mm0–7mm30×30×1mm350Hz standard; 400Hz premium DC transistor version
30E-1515mm0–10.5mm45×45×1mm200Hz

Use 350Hz for the M18 5mm group. All listed AC two-wire models are 20Hz. Frequencies are average values measured with the standard target, spacing between successive targets equal to twice the target width, and a target-to-sensor gap of half the nominal sensing distance. Set the actual operating gap within the setting range.

Electrical Ratings by Circuit

ParameterDC NPN / PNPDC two-wireAC two-wire
Operating voltage10–30VDC90–250VAC
Control output200mA maximum
Leakage current≤10mA≤0.6mA≤10mA
Residual voltage≤1V≤3.5V≤10V
Protection circuitSurge, reverse-polarity and overcurrent protectionSurge protection
Hysteresis≤10% of nominal sensing distance
Temperature influenceWithin ±10% of the sensing distance at 20°C over −25 to +70°C

Cable Construction

Size groupCable outside diameterStandard lengthConductorsStrands per conductor
04E, 05E, 06E, 6.5E2.8mm2m3P22
08E1.5m3P for NPN/PNP; 2P for DC two-wire
12E3.8mm3P for a single NPN/PNP output; 4P for NO+NC; 2P for DC or AC two-wire25
18E, 30E4.8mm30

The cable specification identifies AWG22, 0.1mm individual strand diameter and 1.25mm conductor insulation outside diameter. The strand counts above are strands within each conductor, not the number of external connections. Standard cable is gray PVC; the black cable option is oil-resistant PVC.

Ordering Code Guide

Twelve numbered positions in a CJY-E inductive sensor ordering code
CJY-E ordering layout. Select combinations supported by the model tables above.
PositionCode elementMeaning and choices
1CJInductive sensing
2YCylindrical metal housing
3Size08=M8, 12=M12, 18=M18, 30=M30. The miniature specification separately lists 04, 05, 06 and 6.5 size codes.
4EEconomy series
5Thread lengthBlank=standard; L=long threaded version. Dimensions below apply to the illustrated standard models.
6Sensing distance01=1mm, 02=2mm, 04=4mm, 05=5mm, 08=8mm, 10=10mm, 15=15mm; the 6.5E miniature models use the literal 1.5 distance code.
7SupplyA=90–250VAC; D=10–30VDC. The wider ordering guide also describes E=20–60VDC and J=5–10VDC; these are not additional full models in the selection tables.
8Output circuitN=NPN; P=PNP; K=AC two-wire; L=DC two-wire
9Output stateA=NO; B=NC; C=NO+NC. Use C only for the model groups that list it.
10ConnectionBlank=free-ended cable; M=straight male M12 four-pin A-coded connector. M-type, DT, AMP and SM connector families are also shown with configuration subcodes; their individual subcodes are not defined in the guide.
11Cable materialBlank=PVC; U=PUR; VP=shielded PVC; UP=shielded PUR
12Lead lengthBlank is shown for a direct M-type connector body. L1–L5 denote lead-length choices, with L1=1m and the range not restricted to L5. Standard supplied cable lengths are those in the cable table.

Standard Housing Dimensions

HousingThreadOverall axial referenceThread-length referenceFront projectionNut / across-flats reference
CJY08E-01, flushM8×152mm38mmFlush faceØ15mm / 13mm; nut thickness 3mm
CJY08E-02, nonflush47mm32mm5mm
CJY12E-02, flushM12×158mm38mmFlush faceØ21mm / 17mm; nut thickness 4mm
CJY12E-04, nonflush53mm32mm7mm
CJY18E-05, flushM18×163mm38mmFlush faceØ29mm / 24mm; nut thickness 4mm
CJY18E-08, nonflush58mm32mm10mm
CJY30E-10, flushM30×1.567mm38mmFlush faceØ41mm / 36mm; nut thickness 5mm
CJY30E-15, nonflush59mm32mm11mm

These axial references follow the drawing endpoints and exclude the free cable. The attached drawings show the cable exit, indicator and mounting-nut geometry. The miniature 04E–6.5E groups have electrical specifications but no corresponding dimension drawings in this attachment.

Installation Clearances

Use the lettered geometry in the attached installation drawing: A is face-to-face spacing; B is parallel spacing; n is the required head exposure reference; Ød is the surrounding-metal opening diameter; ℓ and m are the axial / surrounding-metal references shown in the drawing. Values below are in millimeters and preserve the illustrated measurement endpoints.

Model groupABnØdℓm
CJY08E-01916084.512
CJY08E-021224824624
CJY12E-021224012618
CJY12E-04243611361236
CJY18E-0530360181527
CJY18E-08485414542454
CJY30E-1060600303045
CJY30E-15909015904590

Wiring and External Input Examples

For a single NPN/PNP output, brown connects to +V, blue to 0V and black is the output. Connect the load between +V and black for NPN, or between black and 0V for PNP. DC and AC two-wire sensors connect in series with the load; the diagrams allow the load in either lead. Use 90–250VAC for the listed AC models. The attachment retains circuit and NO/NC timing diagrams; the single-output diagrams do not define the fourth conductor of a NO+NC model.

Illustrated deviceSensor supplySensor outputScope
PA10-U, input 1Brown to terminal 9 (+12V); blue to 10 (GND)Black to 11 (IN1)External NPN three-wire connection examples; not additional sensor model designations
PA10-U, input 2Brown to 13 (+12V); blue to 14 (GND)Black to 15 (IN2)
FX4 counterBrown to 10 (+12V); blue to 11 (0V)Black to 8 (CP1)Counter illustration uses a 100–240VAC counter supply; this is not the sensor supply voltage

Environmental and Mechanical Specifications

ItemSpecification
Enclosure protection / indicationIP67; red operating LED
Operating / storage temperature−25 to +70°C / −30 to +80°C, without icing
Humidity35–95%RH, without condensation
Insulation resistance≥50MΩ at 500VDC
Dielectric strength1500VAC at 50/60Hz for 1min
Vibration1mm amplitude, 10–55Hz swept over 1min, 2h in each X/Y/Z direction
Shock500m/s², approximately 50G, three times in each X/Y/Z direction
MaterialsNickel-plated brass case and nuts; nickel-plated iron washers; PBT sensing face; PVC cable
Referenced standardsCCC: GB/T14048.10; TÜV and CE: EN60947-5-2. Supporting certification documents are not included with the selection guide.
Utilization-category referencesDC-13: 10–30VDC, 200mA; AC-140: 24–250VAC, 200mA. These category references do not replace the operating-voltage ratings of individual models.

Application Conditions

Use these sensors for ordinary industrial metal-position detection within the specified target, gap, load and environmental conditions. Regional versions can differ. The manufacturer excludes personnel-safety functions, exceptionally high-reliability systems such as nuclear, gas and power infrastructure, severe outdoor or contaminated environments, fire or explosion hazards, strong acids or alkalis, and military or aerospace use unless specifically designed and confirmed for that application.