CJT Disc Inductive Proximity Sensors

Description

Disc Sensor and Output Selection

CJT inductive sensors provide contactless metal position detection in round PBT housings with two mounting tabs. Select the sensing distance and iron target size together, then choose a DC NPN/PNP three-wire circuit, DC two-wire circuit or AC two-wire circuit. A red LED indicates operation, and enclosure protection is IP67. When replacing a mechanical position switch, match the sensing arrangement, mounting clearance, switching circuit and load.

Sensing Ranges and Test Targets

Housing groupNominal sensing distanceSetting distanceStandard iron targetAverage DC response frequency
CJT36-077mm0-5.5mm50×50×1mm300Hz
CJT42-1010mm0-7.5mm55×55×1mm200Hz
CJT48-1515mm0-12.5mm60×60×1mm100Hz
CJT55-2020mm0-15.5mm80×80×1mm

Response frequency is an average measured with the standard sensing target, target spacing twice the standard target width and a sensing gap equal to half the nominal sensing distance. AC two-wire models have a specified average response frequency of 20Hz.

DC Three-Wire Models

Housing groupNPN modelsPNP modelsSupply
36CJT36-07DNA
CJT36-07DNB
CJT36-07DPA
CJT36-07DPB
10-30VDC
42CJT42-10DNA
CJT42-10DNB
CJT42-10DPA
CJT42-10DPB
48CJT48-15DNA
CJT48-15DNB
CJT48-15DPA
CJT48-15DPB
55CJT55-20DNA
CJT55-20DNB
CJT55-20DPA
CJT55-20DPB

Two-Wire Models

Housing groupDC two-wire, 10-30VDCAC two-wire, 90-250VAC
36CJT36-07DLA
CJT36-07DLB
Not listed
42CJT42-10DLA
CJT42-10DLB
CJT42-10AKA
CJT42-10AKB
48CJT48-15DLA
CJT48-15DLB
CJT48-15AKA
CJT48-15AKB
55CJT55-20DLA
CJT55-20DLB
CJT55-20AKA
CJT55-20AKB

Final A identifies NO and final B identifies NC. N identifies NPN, P identifies PNP, L identifies DC two-wire and K identifies AC two-wire.

Electrical Parameters by Circuit

ParameterDC three-wireDC two-wireAC two-wire
Operating supply10-30VDC90-250VAC
Leakage currentMaximum 10mAMaximum 0.6mAMaximum 10mA
Residual voltageMaximum 1VMaximum 3.5VMaximum 10V
Control outputMaximum 200mA
Response frequency300Hz, 200Hz, 100Hz and 100Hz for 36, 42, 48 and 55 respectively, under the stated test conditions20Hz
HysteresisMaximum 10% of sensing distance
Protection circuitsSurge, reverse polarity and overcurrent protectionSurge and overcurrent protection; bridge-rectified input shown in the circuit diagram

Environmental and Construction Parameters

ParameterSpecification
Temperature effectWithin ±10% of sensing distance over -25°C to +70°C, referenced to +20°C
Insulation resistanceAt least 50MΩ at 500VDC
Dielectric strength1500VAC, 50/60Hz, for 1 minute
Vibration resistance1mm amplitude, 10-55Hz with a 1 minute cycle; 2 hours in each X, Y and Z direction
Shock resistance500m/s², approximately 50G; three shocks in each X, Y and Z direction
IndicatorRed operation LED
Operating temperature-25°C to +70°C, without icing
Storage temperature-30°C to +80°C, without icing
Ambient humidity35-95%RH, without condensation
CasePBT
Standard cableGray PVC
Enclosure protectionIP67

Cable Construction

Housing groupListed cableConductor construction
36 and 42Ø3.8mm, three conductors, 2mAWG22 designation; 25 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter
48 and 55Ø4.8mm, three conductors, 2mAWG22 designation; 30 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter

Cable conductor count and the number of active circuit connections are separate. The two-wire diagrams use brown and blue leads; they do not assign another core to an output or protective earth. Specify the complete cable termination for the selected assembly.

Ordering Positions

CJT disc sensor ordering layout with eleven numbered positions
The eleven positions identify the sensor body, electrical circuit, connection and cable selections.
PositionSelectionCodeMeaning and limits
1ClassificationCJInductive proximity sensor
2ShapeTDisc housing
3Size36, 42, 48, 5536mm, 42mm, 48mm and 55mm disc diameters
4Product versionOmittedStandard form
5Distance07, 10, 15, 207mm, 10mm, 15mm and 20mm respectively, with the model-specific setting ranges above
6SupplyA90-250VAC
D10-30VDC
E20-60VDC configuration
J5-10VDC configuration
7Output circuitNNPN
PPNP
KAC two-wire
LDC two-wire
8Output stateANO
BNC
CCombined NO+NC configuration; no complete C-suffix model is included in the selection tables above
9ConnectionOmittedCable with free leads
MDirect M12 straight four-pin A-coded connector
M plus connector-selection codeM-type cable connector
D plus connector-selection codeDT-type connector
A plus connector-selection codeAMP-type connector
S plus connector-selection codeSM-type connector
10Cable materialOmittedPVC
UPUR
VPShielded PVC
UPShielded PUR
11Cable lengthL1-L5L1 = 1m, through L5 = 5m; other lengths can be specified. Standard cables are 2m.

Specify a complete compatible configuration for alternative supplies, connectors and combined outputs.

Mounting Dimensions

Model groupDisc diameterOverall tab spanMounting-hole spacingMounting holes and cable
CJT36-0736mm53mm44.4mmTwo Ø4.4mm holes; Ø3.8mm cable
CJT42-1042mm65.8mm53.4mmTwo Ø5.8mm holes; Ø3.8mm cable
CJT48-1548mm74.6mm61.4mmTwo Ø5.8mm holes; Ø4.8mm cable
CJT55-2055mm82.7mm67.8mm

The attachment shows the cable outlet, mounting orientation and indicator position for each size.

Wiring and Interface Examples

CircuitSupply and leadsLoad connection
DC NPN three-wireBrown: positive supply
Blue: 0V
Black: output
Load between positive supply and black output
DC PNP three-wireLoad between black output and 0V
DC two-wireBrown and blue active leadsLoad in series, in either lead
AC two-wireBrown and blue active leads; 90-250VAC operating range. The connection illustration uses a 100-240VAC example.Load in series, in either lead
Illustrated interfaceBrownBlueBlackSelection note
PA10-UTerminal 9, +12VTerminal 10, GNDTerminal 11, IN1Three-wire connection example
PA-12Terminal 6Terminal 5Terminal 4Select the matching NPN/PNP setting on the interface

These are external interface connection examples. Use the full circuit diagrams in the attachment and match the selected sensor's output and supply.

Reference Standards and Ratings

ReferenceStandardDocumentation
CCCGB/T 14048.10Obtain model-specific documentation for the chosen circuit and configuration.
TUVEN 60947-5-2
CE
Utilization categoryReference ratingSupply distinction
AC-140200mA at 24-250VACThe listed AC operating range is 90-250VAC
DC-13200mA at 10-30VDCOperating range of the listed DC models

Application Conditions

The range is intended for ordinary industrial control. Nuclear, gas or power systems requiring exceptional reliability, personal-safety functions, harsh outdoor or contaminated environments, fire or explosion hazards, military use and aerospace require a specifically designed and confirmed configuration.