CJF-E Economy Square Inductive Proximity Sensors

Description

CNTD CJF-E economy square inductive proximity sensors provide 5–15mm nominal metal detection in ABS housings with IP67 protection, red operating indicators and 1.5m prewired cables. Five housing sizes offer NPN/PNP and DC two-wire choices; the 25E, 30E and 40E groups also have AC two-wire models. Match the full model designation to its circuit and setting-range entry.

Model Selection

DNA/DNB identify NPN NO/NC, DPA/DPB identify PNP NO/NC, DDA/DDB are the listed DC two-wire NO/NC models, and AKA/AKB are AC two-wire NO/NC models.

Housing / nominal distanceNPNPNPDC two-wireAC two-wire
17E / 5mmCJF17E-05DNA
CJF17E-05DNB
CJF17E-05DPA
CJF17E-05DPB
CJF17E-05DDA
CJF17E-05DDB
No model listed
18E / 5mmCJF18E-05DNA
CJF18E-05DNB
CJF18E-05DPA
CJF18E-05DPB
CJF18E-05DDA
CJF18E-05DDB
No model listed
25E / 8mmCJF25E-08DNA
CJF25E-08DNB
CJF25E-08DPA
CJF25E-08DPB
CJF25E-08DDA
CJF25E-08DDB
CJF25E-08AKA
CJF25E-08AKB
30E / 12mmCJF30E-12DNA
CJF30E-12DNB
CJF30E-12DPA
CJF30E-12DPB
CJF30E-12DDA
CJF30E-12DDB
CJF30E-12AKA
CJF30E-12AKB
40E / 15mmCJF40E-15DNA
CJF40E-15DNB
CJF40E-15DPA
CJF40E-15DPB
CJF40E-15DDA
CJF40E-15DDB
CJF40E-15AKA
CJF40E-15AKB

Sensing and Setting Ranges

GroupNominal distanceStandard iron targetNPN / PNP setting rangeDC two-wire setting rangeAC two-wire setting rangeDC response frequency
CJF17E-055mm18×18×1mm0–3.5mmNo AC model listed500Hz
CJF18E-0525×25×1mm0–3.5mm
CJF25E-088mm30×30×1mm0–5.6mm350Hz
CJF30E-1212mm40×40×1mm0–8.4mm0–7.5mm0–8.4mm250Hz
CJF40E-1515mm60×60×1mm0–10.5mm0–12.5mm0–10.5mm100Hz

Setting ranges depend on the circuit for the 30E and 40E groups; do not substitute the NPN/PNP gap for a DC two-wire selection. AC response frequency is 20Hz. Frequencies are average values using the standard iron target, an interval between successive targets equal to twice the target width, and a sensing gap equal to half the nominal distance.

Electrical Specifications

ItemNPN / PNPDC two-wireAC two-wire
Operating voltage10–30VDC90–250VAC
Control output200mA maximum
Leakage current≤10mA≤0.6mA≤10mA
Residual voltage≤1V≤3.5V≤10V
Protection circuitsSurge, reverse-polarity and overcurrent protectionSurge protection
Hysteresis≤10% of nominal sensing distance
Temperature influenceWithin ±10% of the sensing distance at 20°C over −25 to +70°C

The DC transistor description also identifies overload and short-circuit protection. Match load current and leakage requirements to the selected control input; two-wire and transistor circuits have different voltage drops.

Cable Construction

Housing groupOutside diameterLengthConductorsStrands per conductor
17E / 18E3.8mm1.5m3P for NPN/PNP; 2P for DC or AC two-wire, where a corresponding model is listed25
25E / 30E / 40E4.8mm30

The cable specification identifies AWG22, 0.1mm individual strand diameter and 1.25mm conductor insulation outside diameter. The 25/30 figures describe strands within each conductor. Standard cable is dark gray PVC, and the housing is ABS.

Ordering Code Layout

Eleven numbered positions in a CJF-E economy square inductive sensor code
CJF-E ordering layout with the economy E designation and cable suffix.
PositionFieldKnown choices
1CJInductive sensing
2FSquare housing
3Size17, 18, 25, 30 or 40 housing group; use the actual dimensions below
4EEconomy type
5Distance05=5mm; 08=8mm; 12=12mm; 15=15mm
6SupplyD=10–30VDC; A=90–250VAC. E=20–60VDC and J=5–10VDC are general guide options without full models in the selection above.
7Output circuitN=NPN; P=PNP; K=AC two-wire. Listed DC two-wire models use the full DDA/DDB designations above; L is also described as a general DC two-wire option.
8Output stateA=NO; B=NC. C=NO+NC appears as a general guide choice, without full combined-output models in these tables.
9ConnectionBlank=free-ended cable; M=straight male M12 four-pin A-coded connector. M-type, DT, AMP and SM connector configurations have additional placeholders without individual subcode definitions here.
10Cable materialBlank=PVC; U=PUR; VP=shielded PVC; UP=shielded PUR
11Lead lengthL1–L5 denote lead-length choices, with L1=1m and lengths not restricted to L5. The standard supplied cable length is 1.5m.

Housing and Mounting References

HousingBody lengthSquare cross-sectionMounting-position references
CJF17E-0528mm17×17mm24.6mm axial reference; 11mm between illustrated mounting centers
CJF18E-0536.2mm18×18mm26.3mm and 6.8mm axial references; 10.8mm between slot centerlines
CJF25E-0839.2mm25×25mm34.55mm and 1.2mm axial references; 17.9mm between mounting centers
CJF30E-1253.2mm30×30mm45mm and 4mm axial references; 22mm between slot centerlines
CJF40E-1553mm40×40mm47.4mm and 2mm axial references; 30mm between slot centerlines

These body dimensions exclude the free cable. Use the complete drawings for slot shape, cable-exit location and indicator position; the references above do not specify an unlisted mounting-hole diameter.

Installation Spacing and Metal Clearance

All values are millimeters. A and B are the face-to-face and parallel distances shown in the attachment; C, the table's φd row, ℓ and m correspond to the surrounding-metal geometry. The drawing labels the φd reference as d; preserve its illustrated endpoints when checking a rectangular installation. An additional opposing orientation carries a separate 180mm reference; use the diagram matching the actual orientation.

GroupABCφd / dℓm
CJF17E-0530365152418
CJF18E-0548405243320
CJF25E-0830405152520
CJF30E-1260505303025
CJF40E-15120705604535

Wiring and External Input Examples

For NPN/PNP single outputs, brown is +V, blue is 0V and black is the switching output. Connect an NPN load between +V and black, or a PNP load between black and 0V. DC and AC two-wire models connect in series with the load, which may be placed in either lead. The listed AC models operate at 90–250VAC. The attachment retains circuit and NO/NC timing diagrams.

External exampleSupply leadsOutputSelection note
PA10-U input 1Brown to 9 (+12V); blue to 10 (GND)Black to 11 (IN1)Illustrated DC three-wire sensor connection
PA-12 power amplifierBrown to 6; blue to 5Black to 4Set the amplifier's NPN/PNP selection switch to match the sensor

Environmental Ratings and Standards

ItemSpecification
Protection / indicationIP67; red operating LED
Operating / storage temperature−25 to +70°C / −30 to +80°C, without icing
Humidity35–95%RH, without condensation
Insulation resistance≥50MΩ at 500VDC
Dielectric strength1500VAC, 50/60Hz, 1min
Vibration1mm amplitude, 10–55Hz swept over 1min, 2h per X/Y/Z direction
Shock500m/s², approximately 50G, three times per X/Y/Z direction
Referenced standardsCCC: GB/T14048.10; TÜV and CE: EN60947-5-2. Supporting certification documents are not included.
Utilization referencesDC-13: 10–30VDC, 200mA; AC-140: 24–250VAC, 200mA. Model operating ratings remain those in the circuit table.

Application Conditions

Use for ordinary industrial metal-position detection within the specified target, gap, load and mounting conditions. Regional specifications can differ. The manufacturer excludes personnel-safety functions, exceptionally high-reliability nuclear, gas and power systems, harsh outdoor or contaminated environments, fire or explosion hazards, strong acids or alkalis, and military or aerospace applications unless specifically designed and confirmed for that purpose.