Series Part Number

Part Number: C H 6 S - 2P 2
Explanation:

Prefix

C - Fixed brand prefix

Product Series

H - Counter/timer series

Display Digits

6 - Six-digit display, integer maximum 999999; used by the six listed models
4 - Four-digit ordering option, integer maximum 9999

Front Size

S - 48×48mm
M - 72×72mm

Preset Stages

1P - One-stage setting
2P - Two-stage setting

Supply Voltage

4 - 100–240VAC, 50/60Hz
2 - 24VAC, 50/60Hz or 24–48VDC

Description

CH6 combines preset counting and timing in 48mm and 72mm panel instruments. Counter operation offers nine input patterns, eleven output modes, batch counting and an adjustable initial count. Timer operation offers thirteen output modes, forward/countdown timing, twelve time formats and power-off memory.

Complete models

ModelFront sizePreset stagesSupplyDisplay
CH6S-1P448×48mmOne100–240VAC, 50/60HzSix digits
CH6S-1P2One24VAC, 50/60Hz or 24–48VDC
CH6S-2P4Two100–240VAC, 50/60Hz
CH6S-2P2Two24VAC, 50/60Hz or 24–48VDC
CH6M-1P472×72mmOne100–240VAC, 50/60Hz
CH6M-2P4Two100–240VAC, 50/60Hz

Ordering fields

Six-position CH timer and counter ordering diagram
Prefix, product series, display digits, front size, preset stages and supply code. Example: CH6S-2P2.
PositionCodeMeaning
1: PrefixCFixed brand prefix
2: SeriesHCounter/timer
3: Display digits6Six digits, integer display up to 999999; used by the complete models above
4Four-digit ordering option, integer display up to 9999
4: Front sizeS48×48mm
M72×72mm
5: Preset stages1POne-stage setting
2PTwo-stage setting
6: Supply4100–240VAC, 50/60Hz
224VAC, 50/60Hz or 24–48VDC

Counting inputs and signal levels

Input modeCount pattern
UPUp-count pattern
UP-1Up-count variant 1
UP-2Up-count variant 2
dnDown-count pattern
dn-1Down-count variant 1
dn-2Down-count variant 2
Ud-AUp/down with direction input
Ud-bIndividual up/down input pulses
Ud-CPhase-difference up/down inputs

The complete INA/INB charts distinguish the gating, edge and phase relationships for each pattern. In the charts, A must be at least the minimum signal width and B at least half that width. Shorter signals can produce a count error of ±1.

All nine CH6 counter input timing patterns
UP, UP-1, UP-2, dn, dn-1, dn-2 and Ud-A/b/C input diagrams with count traces and minimum-width conditions.
Logical statePNP voltage inputNPN voltage-free input
H5–30VDCShort circuit
L0–2VDCOpen circuit
Counting speedMinimum signal width
1cps500ms
30cps16.7ms
1kcps0.5ms
5kcps0.1ms
10kcps0.05ms
CH6 input pulse high and low interval requirements
Ton and Toff are the minimum high/low signal intervals for the selected counting speed.

Counter output modes

Output modeApplicable input groups
FUp / Up-1 / Up-2; Down / Down-1 / Down-2; Up/Down A / B / C
N
C
R
K
P
Q
A
SUp/Down A / B / C
T
D

Choose the required threshold, pulse, hold and reset behavior from the response charts. A one-stage instrument's OUT corresponds to OUT2 of a two-stage instrument. In two-stage operation, OUT1 can use one-shot or hold output. OUT1's preset can be zero in all output modes; OUT2's preset cannot be zero in C, R, P or Q.

CH6 counter output timing charts for modes F N C R K P Q A
Eight output patterns compared across up, down and up/down input groups, retaining preset, reset and both output traces.
CH6 counter output timing charts for modes S T D
Additional S, T and D patterns for up/down input operation.

Timer modes

CodeTiming functionPower-on behavior
ONDSignal delayReset
OND.1Signal delay, variant 1Reset
OND.2Power-up delayHold
FLKFlashingReset
FLK.1Flashing, variant 1; hold or one-shot outputReset
FLK.2Flashing, variant 2; hold or one-shot outputHold
INTIntervalReset
INT.1Interval, variant 1Reset
INT.2Interval, variant 2Reset
OFDSignal off-delayReset
NFDOn/off delayReset
NFD.1On/off delay, variant 1Reset
INTGAccumulated integration timingReset

Timer settings cover 0.001s–99999.9h with twelve time-format choices, forward timing or countdown. The one-shot output duration is 0.01–99.99s in 10ms steps. Select the mode-specific response to START, INHIBIT and RESET from the complete diagrams.

All thirteen CH6 timer output modes and start inhibit reset response diagrams
All timer-mode charts, including both hold and one-shot traces where provided.

Electrical and environmental ratings

ParameterRating
Power consumption≤12VA; mains-supply wiring examples are marked 5VA
Counter display rangeScaled range 0.00001–99999.9, according to decimal/unit settings
Counter reset signal width1ms or 20ms selectable
Timer control signalsINA, RESET, INHIBIT and BATCH RESET; 2ms or 20ms selectable minimum signal width
Memory retention10 years, non-volatile semiconductor memory
ConnectionTerminal block
Auxiliary supply shown in wiring12VDC, 100mA
Relay output shown in wiring3A at 250VAC; one or two preset-stage outputs according to model
Transistor outputs shown in wiringMaximum 30VDC, 100mA; functions and terminals depend on model
Utilization ratingsAC-15: Ie 3A at 250VAC/380VAC; DC-13: Ie 3A at 24–48VDC
Operating temperature−25 to +70°C, unfrozen
Storage temperature−30 to +80°C, unfrozen
Humidity35–95%RH, non-condensing
Conformity referencesCCC: GB/T14048.5; CE: EN60947-5-1; applicable documentation depends on the ordered model

Connections and mounting dimensions

CH6S and CH6M one-stage and two-stage wiring diagrams
All four terminal arrangements, including INA/INB, reset, auxiliary supply, relay and transistor outputs; M versions also show batch/reset and bus connections.
FormatFront sizeShell dimensionsPanel opening
CH6S48×48mm44.3×44.3×81mm45×45mm
CH6M72×72mm67×67×81mm68×68mm
CH6S and CH6M enclosure drawings
48mm S and 72mm M enclosure formats.

Application conditions

These industrial instruments are not intended for exceptionally high-reliability nuclear, gas or power systems; personal or property safety functions; harsh outdoor, contaminated, electromagnetic, vibration or shock environments; fire or explosion hazards; or military and aerospace applications unless specifically designed for that use and confirmed in writing.