CGY-E economy photoelectric sensors combine cylindrical threaded housings with diffuse, retro-reflective or through-beam sensing. Diffuse models detect reflected light from the target, retro-reflective models operate with a separate reflector, and through-beam models use an opposed emitter and receiver. The listed infrared models operate from 10-30VDC, with NPN or PNP outputs and IP65 protection.
| Housing | Sensing distance | NPN models | PNP models |
|---|---|---|---|
| M12 | 5cm | CGY12E-DC05DNA CGY12E-DC05DNB | CGY12E-DC05DPA CGY12E-DC05DPB |
| 10cm, adjustable | CGY12E-DC10DNA CGY12E-DC10DNB | CGY12E-DC10DPA CGY12E-DC10DPB | |
| M18 | 10cm | CGY18E-DC10DNA CGY18E-DC10DNB CGY18E-DC10DNC | CGY18E-DC10DPA CGY18E-DC10DPB CGY18E-DC10DPC |
| 30cm, adjustable | CGY18E-DC30DNA CGY18E-DC30DNB CGY18E-DC30DNC | CGY18E-DC30DPA CGY18E-DC30DPB CGY18E-DC30DPC | |
| M30 | 50cm | CGY30E-DC50DNA CGY30E-DC50DNB CGY30E-DC50DNC | CGY30E-DC50DPA CGY30E-DC50DPB CGY30E-DC50DPC |
| 70cm, adjustable | CGY30E-DC70DNA CGY30E-DC70DNB CGY30E-DC70DNC | CGY30E-DC70DPA CGY30E-DC70DPB CGY30E-DC70DPC |
| Housing | Sensing distance | NPN models | PNP models |
|---|---|---|---|
| M12 | 1m | CGY12E-RM1DNA CGY12E-RM1DNB | CGY12E-RM1DPA CGY12E-RM1DPB |
| M18 | 2m | CGY18E-RM2DNA CGY18E-RM2DNB CGY18E-RM2DNC | CGY18E-RM2DPA CGY18E-RM2DPB CGY18E-RM2DPC |
| M30 | 4m | CGY30E-RM4DNA CGY30E-RM4DNB CGY30E-RM4DNC | CGY30E-RM4DPA CGY30E-RM4DPB CGY30E-RM4DPC |
| Reflector selection | Model scope | Selection requirement |
|---|---|---|
| HD08 | Retro-reflective family | High-end reflector option |
| HDE08 | Standard reflector option | |
| HDE02 | CGY18E-RM2DNA and CGY30E-RM4DNA | Additional listed reflector selection |
Specify the reflector with the sensor. Confirm that the selected reflector and target arrangement achieve the required working distance; the reflector options are not an assurance of identical optical performance.
| Housing | Sensing distance | NPN models | PNP models |
|---|---|---|---|
| M12 | 3m | CGY12E-TM3DNA CGY12E-TM3DNB | CGY12E-TM3DPA CGY12E-TM3DPB |
| M18 | 5m | CGY18E-TM5DNA CGY18E-TM5DNB CGY18E-TM5DNC | CGY18E-TM5DPA CGY18E-TM5DPB CGY18E-TM5DPC |
| 10m | CGY18E-TM10DNA CGY18E-TM10DNB CGY18E-TM10DNC | CGY18E-TM10DPA CGY18E-TM10DPB CGY18E-TM10DPC | |
| M30 | 10m | CGY30E-TM10DNA CGY30E-TM10DNB CGY30E-TM10DNC | CGY30E-TM10DPA CGY30E-TM10DPB CGY30E-TM10DPC |
| 15m | CGY30E-TM15DNA CGY30E-TM15DNB CGY30E-TM15DNC | CGY30E-TM15DPA CGY30E-TM15DPB CGY30E-TM15DPC |
In the suffix, D identifies the 10-30VDC supply; N identifies NPN and P identifies PNP. The final A means NO, B means NC and C means NO+NC. Combined outputs are listed for M18 and M30, with the appropriate four-conductor connection.
| Parameter | Diffuse | Retro-reflective | Through-beam |
|---|---|---|---|
| Supply for listed models | 10-30VDC | ||
| Light source | Infrared LED, 880nm | ||
| Hysteresis | 3-20% | ||
| Consumption current | Maximum 25mA | Maximum 40mA | |
| Response time | Below 8.2ms | ||
| Residual voltage, listed DC models | Maximum 1V | ||
| Control output | Maximum 200mA | ||
| Temperature effect | Within ±10% of sensing distance over -25°C to +55°C, referenced to +20°C. Operating temperature remains -15°C to +55°C. | ||
| Insulation resistance | At least 50MΩ at 500VDC | ||
| Dielectric strength | 1500VAC, 50/60Hz, for 1 minute | ||
| Vibration resistance | 1mm amplitude, 10-55Hz with a 1 minute cycle; 2 hours in each X, Y and Z direction | ||
| Shock resistance | 500m/s², approximately 50G; three shocks in each X, Y and Z direction | ||
| Indicator | Red operation LED | ||
| Operating temperature | -15°C to +55°C, without icing | ||
| Storage temperature | -15°C to +55°C, without icing | ||
| Humidity | 35-95%RH, without condensation | ||
| Protection circuits | Surge, reverse polarity and overcurrent protection | ||
| Case and nut | ABS for the listed plastic models | ||
| Sensing surface | PMMA | ||
| Washer | Not separately specified | Plastic | Not separately specified |
| Cable materials and colors | Standard gray PVC; oil-resistant black PVC. PUR and shielded alternatives are selected separately. | ||
| Enclosure protection | IP65 | ||
| Housing group | Cable | Construction references |
|---|---|---|
| M12 models | Ø3.8mm, three conductors, 1.5m | AWG22 designation; 25 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter |
| M18 and M30 models | Ø4.8mm, 1.5m; three conductors for NO/NC, four for combined outputs | AWG22 designation; 30 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter. Two-conductor construction is also listed for the separate two-wire configurations. |

| Position | Selection | Code | Meaning and limits |
|---|---|---|---|
| 1 | Classification | CG | Photoelectric sensor |
| 2 | Housing shape | Y | Plastic cylindrical housing |
| YM | Metal cylindrical option; obtain its matching model and dimensions | ||
| 3 | Size | 12, 18, 30 | M12, M18 and M30 model groups |
| 4 | Version | E | Economy range |
| 5 | Sensing method | D | Diffuse |
| R | Retro-reflective | ||
| T | Through-beam | ||
| 6 | Distance | C05, C10, C30, C50, C70, C100 | 5cm, 10cm, 30cm, 50cm, 70cm and 100cm; actual available model combinations are listed above |
| M1, M2, M3, M4, M5, M10, M15 | 1m, 2m, 3m, 4m, 5m, 10m and 15m; use the model-specific sensing method and range | ||
| 7 | Supply | A | 90-250VAC configuration |
| D | 10-30VDC; supply of the listed models | ||
| E | 20-60VDC configuration | ||
| 8 | Output circuit | N | NPN |
| P | PNP | ||
| K | AC two-wire | ||
| L | DC two-wire | ||
| 9 | Output state | A | NO |
| B | NC | ||
| C | NO+NC, for the listed M18 and M30 combinations | ||
| 10 | Light color | Omitted | Infrared |
| R | Red | ||
| G | Green | ||
| B | Blue | ||
| W | White | ||
| 11 | Light source type | Omitted | LED |
| S | Point light source configuration | ||
| 12 | Connection | Omitted | Cable with free leads |
| M | Direct M12 straight four-pin A-coded connector | ||
| M plus connector-selection code | M-type cable connector | ||
| D plus connector-selection code | DT-type connector | ||
| A plus connector-selection code | AMP-type connector | ||
| S plus connector-selection code | SM-type connector | ||
| 13 | Cable material | Omitted | PVC |
| U | PUR | ||
| VP | Shielded PVC | ||
| UP | Shielded PUR | ||
| 14 | Cable length | L1-L5 | L1 = 1m, through L5 = 5m; other lengths can be specified. The listed standard models have 1.5m cables. |
Specify a complete compatible combination for alternative supplies, light sources and connectors. AC configurations have a stated residual-voltage limit of 10V; this is separate from the 1V limit of the listed DC models.
| Housing and method | Thread | Length references | Front and nut references |
|---|---|---|---|
| CGY18E-D | M18×1 | 86.8mm overall; 41.5mm threaded reference; 3mm front reference | 22.53mm nut span; 16.65mm front reference; 8mm and 3.5mm details |
| CGY18E-R | 92.3mm overall; 41.5mm threaded reference; 8.5mm front reference | 22.61mm nut span; 16.85mm and 16.7mm front references; two Ø6.6mm features; 8mm and 3.5mm details | |
| CGY18E-T | 86.7mm overall; 41.5mm threaded reference; 2.9mm front reference | 22.6mm nut span; 16.65mm front reference; 8mm and 3.5mm details | |
| CGY30E-D | M30×1.5 | 85.85mm overall; 41.5mm threaded reference; 1.2mm front reference | 37.55mm nut span; 28mm and 28.2mm front references; two Ø3.5mm features and Ø13mm feature; 10mm and 4.5mm details |
| CGY30E-R | 38mm nut span; 28mm and 28.2mm front references; two Ø3.5mm features and Ø13mm feature; 10mm and 4.5mm details | ||
| CGY30E-T | 38mm nut span; 28mm and 28.2mm front references; two Ø3.5mm features and Ø13mm feature |
Use the attachment to locate each dimension, LED and adjustment position. Obtain the matching drawing for an M12 or alternative metal-housing configuration.
| Reference | Standard | Documentation |
|---|---|---|
| CCC | GB/T 14048.10 | Obtain documentation for the exact model and configuration. |
| TUV | EN 60947-5-2 | |
| CE |
| Utilization category | Reference rating | Operating-supply distinction |
|---|---|---|
| AC-140 | 200mA at 24-250VAC | Reference rating; the AC code option uses 90-250VAC |
| DC-13 | 200mA at 10-30VDC | Supply range of the listed DC models |
The sensors are intended for ordinary industrial control. Nuclear, gas or power systems requiring exceptional reliability, personal-safety functions, harsh outdoor or contaminated environments, fire or explosion hazards, military use and aerospace require a specifically designed and confirmed configuration.