CGU sensors place the emitter and receiver on opposite sides of a slot, providing through-beam detection without aligning separate housings. The listed models use modulated infrared LED light, a 10-30VDC supply and a red operation indicator. Choose the nominal sensing span, output circuit and switching state together. Response time is below 1ms and enclosure protection is IP65.
| Family | Nominal sensing span | NPN models | PNP models | Output states |
|---|---|---|---|---|
| CGU07-07 | 7mm | CGU07-07DNA CGU07-07DNB CGU07-07DNC | CGU07-07DPA CGU07-07DPB CGU07-07DPC | A = NO B = NC C = NO+NC, where listed |
| CGU10-10 | 10mm | CGU10-10DNA CGU10-10DNB | CGU10-10DPA CGU10-10DPB | |
| CGU30-30 | 30mm | CGU30-30DNA CGU30-30DNB CGU30-30DNC | CGU30-30DPA CGU30-30DPB CGU30-30DPC | |
| CGU50-50 | 50mm | CGU50-50DNA CGU50-50DNB CGU50-50DNC | CGU50-50DPA CGU50-50DPB CGU50-50DPC |
D denotes the 10-30VDC supply; N denotes NPN and P denotes PNP. The CGU10 selection does not include a combined-output model.
| Parameter | Specification for the listed DC models |
|---|---|
| Light source | Modulated infrared LED; standard infrared wavelength 880nm |
| Consumption current | Maximum 15mA |
| Response time | Below 1ms |
| Supply | 10-30VDC |
| Residual voltage | Maximum 1V |
| Control output | Maximum 200mA |
| Temperature effect | Within ±10% of sensing distance, referenced to +20°C, over the stated -25°C to +55°C characterization range. Operating temperature remains -15°C to +55°C. |
| Insulation resistance | At least 50MΩ at 500VDC |
| Dielectric strength | 1500VAC, 50/60Hz, for 1 minute |
| Vibration resistance | 1mm amplitude, 10-55Hz with a 1 minute cycle; 2 hours in each X, Y and Z direction |
| Shock resistance | 500m/s², approximately 50G; three shocks in each X, Y and Z direction |
| Indicator | Red operation LED |
| Operating temperature | -15°C to +55°C, without icing |
| Storage temperature | -15°C to +55°C, without icing |
| Ambient humidity | 35-95%RH, without condensation |
| Protection circuits | Surge, reverse polarity and overcurrent protection |
| Housing | ABS |
| Sensing surface | PMMA |
| Standard cable | Gray PVC |
| Oil-resistant cable | Black oil-resistant PVC; optional materials and shielding selected separately |
| Enclosure protection | IP65 |
| Family | Standard cable | Construction references |
|---|---|---|
| CGU07 | Ø4.8mm, three or four conductors according to output configuration, 2m | AWG22 designation; 30 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter |
| CGU10 | Ø3.8mm, three conductors, 2m | AWG22 designation; 25 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter |
| CGU30 and CGU50 | Ø4.8mm, three or four conductors according to output configuration, 2m | AWG22 designation; 30 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter |

| Position | Selection | Code | Meaning and applicability |
|---|---|---|---|
| 1 | Classification | CG | Photoelectric sensor |
| 2 | Shape | U | Slot housing |
| 3 | Size | 07, 10, 30, 50 | Nominal slot selections of 7mm, 10mm, 30mm and 50mm |
| 4 | Product version | Omitted | Standard type |
| 5 | Sensing span | 07, 10, 30, 50 | 7mm, 10mm, 30mm and 50mm respectively |
| 6 | Supply | D | 10-30VDC; used by the listed models |
| E | 20-60VDC configuration | ||
| J | 5-10VDC configuration | ||
| 7 | Output circuit | N | NPN |
| P | PNP | ||
| 8 | Output state | A | NO |
| B | NC | ||
| C | NO+NC for the listed CGU07, CGU30 and CGU50 models | ||
| 9 | Light color | Omitted | Infrared |
| R | Red | ||
| G | Green | ||
| B | Blue | ||
| W | White | ||
| 10 | Light source type | Omitted | LED |
| 11 | Connection | Omitted | Cable with free lead end |
| M plus connector-selection code | M-type connector configuration | ||
| D plus connector-selection code | DT-type connector configuration | ||
| A plus connector-selection code | AMP-type connector configuration | ||
| S plus connector-selection code | SM-type connector configuration | ||
| 12 | Cable material | Omitted | PVC |
| U | PUR | ||
| VP | Shielded PVC | ||
| UP | Shielded PUR | ||
| 13 | Cable length | L1-L5 | L1 = 1m, through L5 = 5m; other lengths can be specified |
Alternative supply, color and connector options require the matching complete model configuration. The standard-model electrical parameters above apply to the listed infrared D-supply models.
| Family | Main dimensions | Mounting and slot references |
|---|---|---|
| CGU07-07 | 54.79mm top-view length; 25mm width; 16mm side-view height | Two Ø3.3mm holes with 15mm spacing; 20mm slot-depth reference; 9mm drawn opening; VR and two LED positions shown |
| CGU10-10 | 29.5mm by 28.4mm top-view references | 19.5mm mounting-spacing reference; 11mm slot-depth and 10mm opening references; additional 2.5mm and 14.2mm locations shown |
| CGU30-30 | 71.89mm length; 52mm width; 13mm side-view height | Two Ø6.5mm holes with 40mm spacing; 45mm slot-depth and 30mm opening references; VR and two LED positions shown |
| CGU50-50 | 78mm by 78mm top-view references | Two Ø6.5mm holes with 66mm spacing; 51.31mm slot-depth and 49.6mm drawn opening references; VR and two LED positions shown |
Nominal optical sensing span and the dimensioned housing opening are separate specifications. Use the full views in the attachment for the mounting pattern, cable exit and remaining feature dimensions.
| Reference designation | Standard | Documentation |
|---|---|---|
| CCC | GB/T 14048.10 | Obtain documentation for the exact model and configuration. |
| TUV | EN 60947-5-2 | |
| CE |
| Utilization category | Reference rating | Model scope |
|---|---|---|
| AC-140 | 200mA at 24-250VAC | Reference category; the listed CGU models use a DC supply |
| DC-13 | 200mA at 10-30VDC | Listed DC models |
The sensors are intended for ordinary industrial control. Nuclear, gas or power systems requiring exceptional reliability, personal-safety functions, harsh outdoor or contaminated environments, fire or explosion hazards, military use and aerospace require a specifically designed and confirmed configuration.