CGF-E Economy Square Photoelectric Sensors

Description

Sensing Method and Output Circuit

CGF-E economy square photoelectric sensors provide diffuse, retro-reflective and through-beam arrangements in three housing groups. Select a 10-30VDC NPN or PNP transistor model for a control input, or a relay-output model with the appropriate DC or AC supply. All listed variants use infrared LED sensing and IP65 housings. Relay-output ratings and cable arrangements are separate from the transistor versions.

Diffuse Transistor Models

Housing groupAdjustable sensing distanceNPN modelsPNP models
3030cmCGF30E-DC30DNA
CGF30E-DC30DNB
CGF30E-DC30DNC
CGF30E-DC30DPA
CGF30E-DC30DPB
CGF30E-DC30DPC
50CGF50E-DC30DNA
CGF50E-DC30DNB
CGF50E-DC30DNC
CGF50E-DC30DPA
CGF50E-DC30DPB
CGF50E-DC30DPC
7050cmCGF70E-DC50DNA
CGF70E-DC50DNB
CGF70E-DC50DNC
CGF70E-DC50DPA
CGF70E-DC50DPB
CGF70E-DC50DPC

Retro-Reflective Transistor Models

Housing groupSensing distanceNPN modelsPNP models
304mCGF30E-RM1DNA
CGF30E-RM1DNB
CGF30E-RM1DNC
CGF30E-RM1DPA
CGF30E-RM1DPB
CGF30E-RM1DPC
50CGF50E-RM1DNA
CGF50E-RM1DNB
CGF50E-RM1DNC
CGF50E-RM1DPA
CGF50E-RM1DPB
CGF50E-RM1DPC
705mCGF70E-RM5DNA
CGF70E-RM5DNB
CGF70E-RM5DNC
CGF70E-RM5DPA
CGF70E-RM5DPB
CGF70E-RM5DPC

Through-Beam Transistor Models

Housing groupSensing distanceNPN modelsPNP models
3010mCGF30E-TM5DNA
CGF30E-TM5DNB
CGF30E-TM5DNC
CGF30E-TM5DPA
CGF30E-TM5DPB
CGF30E-TM5DPC
50CGF50E-TM5DNA
CGF50E-TM5DNB
CGF50E-TM5DNC
CGF50E-TM5DPA
CGF50E-TM5DPB
CGF50E-TM5DPC
7015mCGF70E-TM15DNA
CGF70E-TM15DNB
CGF70E-TM15DNC
CGF70E-TM15DPA
CGF70E-TM15DPB
CGF70E-TM15DPC

For these transistor models, D is the 10-30VDC supply; N is NPN and P is PNP. Final A means NO, B means NC and C means combined NO+NC. The CGF30E and CGF50E RM1 models have a 4m specified range, and their TM5 models have a 10m specified range. Select these models by the values in the tables rather than reading the range directly from the model suffix.

Relay-Output Model Selection

Sensing methodHousing groupSensing distance10-30VDC model90-250VAC model
Diffuse5030cm, adjustableCGF50E-DC30DRCCGF50E-DC30ARC
7050cm, adjustableCGF70E-DC50DRCCGF70E-DC50ARC
Retro-reflective504mCGF50E-RM4DRCCGF50E-RM4ARC
705mCGF70E-RM5DRCCGF70E-RM5ARC
Through-beam5010mCGF50E-TM10DRCCGF50E-TM10ARC
7015mCGF70E-TM15DRCCGF70E-TM15ARC

R identifies the relay output and final C identifies NO+NC contacts. The relay output has a specified 3A control-output rating; select the contact load and switching conditions for the application. The D and A versions have different operating supplies.

Reflector Selection

ReflectorSelection and model scope
HD02Premium selection for the retro-reflective transistor models; also specified for the listed relay-output retro-reflective models
HDE02Standard selection for the retro-reflective transistor family
HDE09Additional selection listed for CGF30E-RM1DNA
HDE08Additional selection listed for CGF50E-RM1DNA and CGF70E-RM5DNA

Specify the reflector with the sensor and confirm the required working range with the selected reflector and alignment.

Electrical Parameters by Output Type

ParameterTransistor diffuse/retroTransistor through-beamRelay diffuse/retroRelay through-beam
Supply10-30VDC10-30VDC for D models or 90-250VAC for A models
Consumption currentMaximum 25mAMaximum 40mAMaximum 25mAMaximum 50mA
Control-output ratingMaximum 200mA3A relay output; load conditions are not separately specified
Residual-voltage limitMaximum 1V
Response timeBelow 8.2ms
Light sourceInfrared LED, 880nm
Hysteresis3-20%
Protection circuitsSurge and overcurrent protection; DC reverse-polarity protection featureSurge protection; reverse-polarity feature applies to DC-supply versions

Environmental and Construction Parameters

ParameterSpecification
Temperature effectWithin ±10% of sensing distance over -25°C to +55°C, referenced to +20°C. Operating temperature remains -15°C to +55°C.
Insulation resistanceAt least 50MΩ at 500VDC
Dielectric strength1500VAC, 50/60Hz, for 1 minute
Vibration resistance1mm amplitude, 10-55Hz with a 1 minute cycle; 2 hours in each X, Y and Z direction
Shock resistance500m/s², approximately 50G; three shocks in each X, Y and Z direction
IndicatorRed operation LED
Operating temperature-15°C to +55°C, without icing
Storage temperature-15°C to +55°C, without icing
Ambient humidity35-95%RH, without condensation
CaseABS
Sensing surfacePMMA
Cable materialsStandard gray PVC or oil-resistant black PVC, where a cable is fitted; other cable options are selected separately
Enclosure protectionIP65

Cable Construction and Connection Selection

Model groupCableConstruction references
CGF30E transistor modelsØ3.8mm, three or four conductors according to output, 1.5mAWG22 designation; 25 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter
CGF50E transistor modelsØ6mm, three or four conductors according to output, 1.5m; a two-conductor construction is also listed for separate two-wire configurationsAWG22 designation; 22 strands of Ø0.1mm per conductor; Ø1.25mm insulation outside diameter
CGF50E relay modelsØ6mm, five conductors, 1.5m
CGF70E modelsCable construction is not specified in the selection tables; specify the connection arrangement with the complete model.

Ordering Positions and Configuration Options

CGF-E square photoelectric sensor ordering layout with fourteen numbered positions
The fourteen positions locate the housing, sensing method, electrical circuit and cable selections.
PositionSelectionCodeMeaning and limits
1ClassificationCGPhotoelectric sensor
2ShapeFSquare housing
3Housing group30, 50, 70Housing selections; use their actual dimensions below
4VersionEEconomy range
5Sensing methodDDiffuse
RRetro-reflective
TThrough-beam
6Distance codeC10, C30, C50, C100General 10cm, 30cm, 50cm and 100cm code selections; use the explicit model tables for availability
M1, M4, M5, M10, M15Distance selections depend on the exact model. RM1 transistor models in the 30/50 housings are rated 4m; their TM5 models are rated 10m.
7SupplyA90-250VAC
D10-30VDC
E20-60VDC configuration
8Output circuitNNPN
PPNP
RRelay
KAC two-wire configuration
LDC two-wire configuration
9Output stateANO
BNC
CNO+NC; select with the transistor or relay output circuit
10Light colorOmittedInfrared
RRed
GGreen
BBlue
WWhite
11Light source typeOmittedLED
SPoint light source configuration
12ConnectionOmittedCable with free leads
MDirect M12 straight four-pin A-coded connector
M plus connector-selection codeM-type cable connector
D plus connector-selection codeDT-type connector
A plus connector-selection codeAMP-type connector
S plus connector-selection codeSM-type connector
13Cable materialOmittedPVC
UPUR
VPShielded PVC
UPShielded PUR
14Cable lengthL1-L5L1 = 1m, through L5 = 5m; other lengths can be specified. Listed 30/50 cable models use 1.5m as standard.

Select alternative supplies, colors, light sources and connectors as complete compatible configurations. A four-pin connector option does not replace the five-conductor connection of a relay model without a matching wiring arrangement.

Mounting Dimensions

Housing groupMethods illustratedMain dimensionsMounting references
CGF30EDiffuse, retro-reflective and through-beam35mm by 21.9mm side-view references; 12mm widthM4 mounting points with 25.4mm spacing; LED position shown
CGF50E50mm by 50mm face; 18mm thickness40.6mm mounting references in both directions; 5mm offsets; R2.28mm features; LED and adjustment positions shown
CGF70E73.77mm by 65.2mm side-view references; 73.8mm top-view length; 25.5mm thicknessTwo Ø4.6mm holes with 40mm spacing; 5.34mm and 9.4mm mounting offsets; additional 15.2mm, 34.2mm and 52.9mm feature locations

Use the complete drawings in the attachment to locate each measurement, cable outlet and adjustment feature.

Standards and Reference Ratings

ReferenceStandardDocumentation
CCCGB/T 14048.10Obtain documents for the exact output circuit and configuration.
TUVEN 60947-5-2
CE
Utilization categoryReference ratingSelection distinction
AC-140200mA at 24-250VACReference category; AC supply-code A uses 90-250VAC
DC-13200mA at 10-30VDCSeparate from the 3A relay-output parameter

Application Conditions

The sensors are intended for ordinary industrial control. Nuclear, gas or power systems requiring exceptional reliability, personal-safety functions, harsh outdoor or contaminated environments, fire or explosion hazards, military use and aerospace require a specifically designed and confirmed configuration.