CDM6 Electronic Pulse and Impulse Relays

Series Part Number

Part Number: CDM6 - 1 2 16 W
Explanation:

Product Family

CDM6 - DIN rail electronic pulse relay

Input Series

1 - Single-pulse input

Output Function

1 - One changeover output
2 - Two changeover outputs; B1/B2 selects sequential or simultaneous response

Output Contact Rating

10 - 10A contact version
16 - 16A contact version

Operating Voltage

M - 220VAC, 50/60Hz; mains-voltage neon switch connection
W - 12–240VAC/DC; AC 50/60Hz

Description

CDM6 electronic pulse relays change the output state in response to a control pulse at A1–S. Choose CDM6-11 for one changeover or CDM6-12 for two changeovers. The dual-output version offers separate output sequencing or simultaneous switching through the B1/B2 configuration.

Models and ordering choices

Complete modelOutputsContact ratingSupply
CDM6-1110MOne changeoverIth 10A; Ie 2.5A220VAC, 50/60Hz
CDM6-1210MTwo changeoversIth 10A; Ie 2.5A
CDM6-1116WOne changeoverIth 16A; Ie 5A12–240VAC/DC; AC 50/60Hz
CDM6-1216WTwo changeoversIth 16A; Ie 5A
Five-position CDM6 electronic pulse relay ordering layout
Ordering example CDM6-1216W: pulse-input series, dual output, 16A contact version and wide-range supply.
PositionCodeMeaning
1: FamilyCDM6DIN rail electronic pulse relay
2: Product series1Single-pulse input
3: Output function1One changeover
2Two changeovers
4: Contact rating1010A version
1616A version
5: Operating voltageM220VAC, 50/60Hz
W12–240VAC/DC; AC 50/60Hz

Pulse response and dual-output operation

For CDM6-11, successive valid input pulses switch the output on and off. The minimum control pulse width is 25ms. For CDM6-12, leave B1/B2 open for the four-state sequence below, or bridge B1/B2 for the two outputs to switch together. The complete charts also show the illustrated response to a supply interruption.

CDM6-12 connectionSequence stageR1: 11–14R2: 21–24
B1/B2 openInitial / fourth pulseOffOff
First pulseOnOff
Second pulseOffOn
Third pulseOnOn
B1/B2 bridgedFirst pulseOnOn
Second pulseOffOff
Single-output and dual-output CDM6 pulse response charts
Single-output toggling, four-state dual-output sequencing with B1/B2 open and simultaneous dual-output toggling with B1/B2 bridged.

Power and output ratings

ParameterCDM6-11CDM6-12
Supply terminalsA1–A2
W supply12–240VAC/DC; AC 50–60Hz
W power consumptionAC: 0.09–3VA; DC: 0.05–1.2W
M supply220VAC, 50–60Hz
M power consumptionAC maximum 12VA / 1.3WAC maximum 12VA / 1.9W
Permitted supply fluctuation−15%, +10%
Control terminals / pulse widthA1–S / minimum 25ms
Output contact arrangement1×SPDT2×SPDT
16A version load rating16A AC-1; contact switching voltage 250VAC/24VDC
Minimum switching power500mW
IndicatorsGreen supply LED; red output LED
Reset timeMaximum 200ms
Mechanical / resistive electrical life1×10⁷ / 1×10⁵ operations
Weight, W / M version58g / 57g79g / 77g

The contact current rating is separate from the relay supply voltage. Use the rating of the selected 10A or 16A version for the intended load.

Neon switches and installation conditions

ParameterCondition
Neon switch connectionM mains-voltage version, A1–S; connection quantity characterized at 230VAC
Maximum neon quantity75 at 230VAC, based on approximately 0.68mA per neon
Operating temperature−20 to +55°C
Storage and transport temperature−35 to +75°C
Mounting / orientation35mm DIN rail / any orientation
Protection / altitude / pollution degreeIP20 / ≤2000m / 2
Conductors / tightening torque1×2.5mm² or 2×1.5mm² / 0.4N·m
Overall dimensions90×18×65mm
Conformity designations3C and CE; applicable documentation depends on the ordered model

Connections and lighting example

The single-output contacts are 11/12/14; the dual-output version adds 21/22/24. Connect momentary control switches to A1–S and configure B1/B2 on the dual-output version as required by the response chart.

CDM6 single and dual changeover terminal and lighting circuits
Both terminal diagrams and lighting circuits, including the B1/B2 connection on the dual-output version.
CDM6 pulse relay lighting control from multiple room locations
Room lighting example: momentary switches at different locations control separate lighting groups through R1 and R2.
CDM6 electronic pulse relay mounting dimensions
Dimensions in millimetres: 90 height, 18 width, 65 depth, with 31 and 19 profile references. Follow the wiring diagrams for terminal functions.

Application conditions

These industrial relays are not intended for exceptionally high-reliability nuclear, gas or power systems; personal or property safety functions; harsh outdoor, contaminated, electromagnetic, vibration or shock environments; fire or explosion hazards; or military and aerospace applications unless specifically designed for that use and confirmed in writing.