| Part Number: | CD60 | - | 10B |
|---|---|---|---|
| Explanation: |
Series CD60 - Plastic-case electrolytic motor starting capacitor series. Specify capacitance, voltage, tolerance and starting duty separately. |
Case configuration 7A - Recessed tab terminals without a bottom mounting stud |
CD60 plastic-case capacitors serve the starting circuits of single-phase motors and refrigeration compressors at 50/60Hz. The construction uses aluminum foil and paper in a sealed plastic or bakelite case, with moisture and oil resistance. Select the capacitance, voltage, case dimensions and starting duty as a matched configuration.
| Parameter | Rating or scope |
|---|---|
| Rated voltage range | 110–330VAC |
| General capacitance offering | 21–1280µF |
| Technical capacitance range | 21–1200µF, measured at 20°C and 120Hz |
| General capacitance tolerance | 0% to +20% |
| Additional illustrated tolerance option | ±10% on the depicted CD60-8A, CD60-8B, CD60-10A and CD60-10B configurations |
| Dissipation factor | tanδ≤0.15 at 20°C and 120Hz |
| Surge voltage test | 1.2 times rated voltage for 2s |
| Terminal-to-case withstand test | 2000VAC for 10s, without breakdown |
| Reference specifications | EIA-463-A; ANSI/EIA-463 |
| Configurations | Marked climatic category | Lower category temperature | Upper category temperature | Damp-heat test duration |
|---|---|---|---|---|
| CD60-7A, CD60-7B, CD60-8A, CD60-8B, CD60-10A, CD60-10B illustrated versions | 20/55/21 | -20°C | +55°C | 21 days |
Climatic-category temperatures describe the marked test category. The 21-day value is a damp-heat test duration, not operating life. Match the thermal requirements of the application to the selected component rating and starting duty.
| Test attribute | Series-level test range |
|---|---|
| Energized time per cycle | 1s |
| Cycle period | 0.5–4 minutes, depending on rated voltage and capacitance |
| Endurance count | 12500–50000 cycles under the applicable voltage- and capacitance-dependent schedule |
The test schedules span different electrical ratings. The shortest cycle and highest endurance count are not a combined rating for every configuration. Specify the required starting frequency and duty when selecting the capacitor.
D×L dimensions are in mm. Capacitance bands with identical case dimensions are grouped together.
| Rated voltage | Capacitance band (µF) | D×L (mm) |
|---|---|---|
| 220–275VAC | 40–70, 80–110, 108–140, 138–174 | 37×70 |
| 161–193, 180–225, 225–270, 270–324 | 46×86 | |
| 324–380, 340–403, 400–500, 500–645 | 46×111 | |
| 645–708 | 52×111 | |
| 708–850 | 65×111 |
This separate dimensional schedule includes alternative case sizes for some ratings. A dash indicates no listed size for that combination. Dimensions are D×L in mm.
| Capacitance or band (µF) | CD60 case dimensions D×L (mm) | ||
|---|---|---|---|
| 110/125VAC | 220/250VAC | 300/330VAC | |
| 20–25, 25–30, 30–36, 36–43, 43–52 | 37×70 | 37×70 | 37×86 |
| 47–56, 53–64, 64–77, 72–86, 88–106, 100 | 46×111 | ||
| 108–130, 124–149, 130–156, 145–174, 150 | 52×111 | ||
| 161–193, 189–227, 200 | 46×86 | ||
| 216–259, 233–280, 243–292, 250 | 37×70 or 37×86 | ||
| 270–324 | 65×111 | ||
| 300 | — | ||
| 324–380, 340–408, 378–457 | 37×86 or 46×86 | 46×111 | |
| 400, 400–480, 430–516, 460–552, 500, 540–648, 600 | 46×86 | ||
| 645–774, 700 | 52×111 | ||
| 708–850 | 65×111 | ||
| 720–864, 800, 800–960, 815–978, 829–995 | — | ||
| 1000, 1000–1200 | 52×86 | ||
Standard termination uses 1/4in quick-disconnect tabs. Recessed terminals, covered arrangements, cable leads and stud-mounted constructions are illustrated below. The general case offering includes eight standard sizes spanning 1.437×2.750in to 2.562×4.375in; use the voltage-specific dimension schedules to select a listed configuration. Other dimensions can be specified for individual applications.