Series Part Number

Part Number: CBX 22 - S 1 Y - P
Explanation:

Series

CBX - Button box enclosure series

Operator Opening

22 - Nominal 22mm operator mounting; cover hole drawing diameter is 22.4mm

Enclosure Height

S - 60mm height
H - 73mm height

Number of Openings

1 - One opening
2 - Two openings
3 - Three openings
4 - Four openings
5 - Five openings

Cover Color

Blank - Gray cover; omit this code
Y - Yellow cover

Protection Option

Blank - Standard IP65 option; omit this code and its preceding final hyphen
P - IP67 option. Match operators and cable entries to the intended completed enclosure protection.

Description

CBX22 Enclosures for 22mm Panel Operators

CBX22 button boxes provide one to five mounting positions for 22mm pushbuttons, selector switches or indicator devices. Two enclosure depths are specified: S for 60mm and H for 73mm. The deeper H version provides more space behind the cover for the selected operator and wiring. The photographed boxes have gray covers; a yellow cover is an ordering option.

The standard protection option is IP65, with P denoting IP67. Select the protection version as part of the enclosure order, then match the fitted operators and cable entries to the completed assembly. Opening count, depth, cover color and protection are separate choices; the number of openings does not specify a prewired control function.

Series Part Number Guide

CBX22 enclosure ordering layout with series, 22mm opening, height, opening count, cover color and protection
CBX22 ordering layout. The gray cover and standard IP65 options omit their suffix codes.
FieldCodes and meaningOrdering condition
SeriesCBX: button box enclosureFollowed directly by the opening size.
Opening size22: nominal 22mm operator mountingThe dimension drawings specify Ø22.4mm cover holes.
HeightS: 60mm; H: 73mmChoose the available space for the assembled operator and terminals.
Opening count1, 2, 3, 4 or 5Number of cover openings.
Cover colorBlank: gray; Y: yellowY follows the opening count without an extra separator.
ProtectionBlank: IP65; P: IP67For IP67 add -P after the other options; omit both the final hyphen and P for standard IP65.

Model and Dimension Comparison

All dimensions below are in millimeters. Width and length tolerances are ±0.15; enclosure height tolerance is ±0.2. The front operator holes are Ø22.4. Asterisks identify dimensions inferred from the common spacing relationships, as explained beneath the table.

Openings60mm model73mm modelWidth × lengthRear fixing centers, transverse × longitudinal
1CBX22-S1CBX22-H173.6×73.654×40
2CBX22-S2CBX22-H273.6×113.654×80
3CBX22-S3CBX22-H373.6*×153.6*54×120
4CBX22-S4CBX22-H473.6×193.654×160
5CBX22-S5CBX22-H573.6×233.654×200*

* Dimensional interpretation: the three-opening width and length are taken as 73.6 and 153.6 from the common enclosure width and 40mm length progression; the printed three-opening drawing omits the final .6. The five-opening longitudinal fixing pitch is taken as 200 from the 40mm progression of the fixing centers and common end offsets; its printed value repeats 160. These three values are inferred, so verify them against the actual enclosure before fabrication or drilling.

Layout detailDimension
Operator hole diameterØ22.4mm
Adjacent operator hole centers40mm in the multi-opening layouts
First to third operator center80mm where applicable
First to fourth operator center120mm in the four-opening layout
First to fifth operator center160mm in the five-opening layout
Rectangular legend recess shown in the front drawings12×28mm
Enclosure depthS: 60±0.2mm; H: 73±0.2mm

Configuration Examples and Fit

CBX22-S1 identifies a 60mm enclosure with one 22mm operator opening, gray cover and standard IP65 option. CBX22-S1Y-P selects the same depth and opening count with a yellow cover and IP67 protection option. The PDF includes S and H dimension variants through five openings, extending the four gray S models shown in the product photographs.

Check the rear length of the chosen operator, contact blocks and wiring against the S or H enclosure depth. Use the complete mechanical drawings for mounting details, side entry positions and cover layout. Specify the complete enclosure code and the operators required for the application; the enclosure selection does not itself define lamp voltage, contact arrangement or circuit wiring.