C6N IP67 Compact Prewired Limit Switches

Series Part Number

Part Number: C6N - P 1 11 - U L2
Explanation:

Series

C6N - Compact prewired limit switch series

Housing

P - Plastic housing

Contacts

1 - Snap-action 1NC/1NO with silver contacts

Actuator

11 - Top plunger
22 - Transverse metal roller plunger
23 - Vertical metal roller plunger
17 - M12 top plunger
24 - M12 transverse metal roller plunger
25 - M12 vertical metal roller plunger
15 - Right-facing cantilever roller
16 - Left-facing cantilever roller
04 - Metal lever with resin roller
05 - Metal lever with metal roller
07 - Adjustable rod lever
08 - Adjustable metal lever with resin roller
09 - Adjustable metal lever with metal roller
66 - Plastic rod with spring
67 - Coil spring
68 - Metal rod with coil spring
69 - Flexible whisker
Direct opening - Applies to the NC contact of heads 11, 22, 23, 17, 24, 25, 15, 16, 04, 05, 07, 08 and 09; no direct-opening specification for heads 66–69

Cable outlet

NONE - Standard side outlet; omit this code

Cable material

NONE - PVC cable; omit the material code and retain the separator before the length code
U - Oil-resistant PUR cable

Cable length

L1 - 1m
L2 - 2m
L3 - 3m
L4 - 4m
L5 - 5m; other lengths may be specified separately

Description

Compact prewired position switches

C6N switches have an injection-molded plastic housing, IP67 protection and a standard side cable outlet. The body is 30mm wide, 50mm high and 16mm thick. Seventeen head designs cover direct plunger operation, roller contact, adjustable levers and flexible spring actuation. All use snap-action 1NC/1NO silver contacts.

Choose the actuator for the cam direction and available travel, then specify the cable material and length. PVC is the standard cable; code U selects oil-resistant PUR. L1–L5 designate 1–5m cables. The illustrated -L2 products have 2m cable; a base model name without a length suffix does not specify a cable length. The example C6N-P111-UL2 combines a top plunger, standard side outlet and 2m PUR cable.

Actuator selection and direct opening

Base modelHead designKey geometryNC direct opening
C6N-P111Top plungerStainless steel plunger, Ø7mmSpecified for NC only
C6N-P122Transverse metal roller plungerStainless steel roller, Ø11.6×4mm
C6N-P123Vertical metal roller plunger
C6N-P117M12 top plungerM12×1 thread; Ø7.5mm stainless steel plunger
C6N-P124M12 transverse metal roller plungerM12×1 thread; Ø11.6×4mm stainless steel roller
C6N-P125M12 vertical metal roller plunger
C6N-P115Right-facing cantilever rollerPlastic roller, Ø14×5.5mm
C6N-P116Left-facing cantilever roller
C6N-P104Metal lever with resin rollerØ18×6.5mm roller; 26.5mm lever radius
C6N-P105Metal lever with metal roller
C6N-P107Adjustable rod leverØ3×160mm stainless steel rod; 210mm maximum overall height
C6N-P108Adjustable metal lever with resin rollerØ18×6.5mm roller; 25.5–75.5mm adjustable radius
C6N-P109Adjustable metal lever with metal roller
C6N-P166Plastic rod with spring38mm plastic tip; 167mm overall heightNot specified
C6N-P167Coil springMetal tip; 169.5mm overall height
C6N-P168Metal rod with coil spring57mm metal tip; 166mm overall height
C6N-P169Flexible whisker167mm overall height

Direct opening applies only to the NC contact and only to the heads identified above. It is not a claim that every actuator is suitable for a safety circuit. Flexible heads P166–P169 have no specified direct-opening travel or force.

Electrical ratings and operating environment

ParameterValue or condition
Contact arrangementSnap-action 1NC/1NO; silver contacts
Rated insulation voltage Ui400V
Rated impulse withstand voltage Uimp4kV
Conventional free-air thermal current Ith6A
Insulation resistanceAt least 100MΩ at 500VDC
Minimum applicable load24VDC, 10mA
Contact gapMinimum 4×0.5mm, snap action
Operating speed1mm/s–0.5m/s
Electrical operating frequency30 operations/min
Ingress protectionIP67
Electric shock protectionClass II, double insulated
Pollution degree3 to EN 60947-5-1
Vibration resistance against malfunction10–55Hz, 1.5mm double amplitude
Shock resistanceMechanical durability: 1000m/s²; malfunction: 500m/s²
Ambient temperature-25°C to +70°C, without icing
Ambient humidityBelow 95%RH
Utilization categoryRated operating loadElectrical durability at that load
AC-151.5A at 240VACMore than 300,000 cycles
DC-130.1A at 250VDCMore than 500,000 cycles

The 6A thermal current is not an AC-15 or DC-13 switching rating. Select the load by its voltage and utilization category. Durability values apply to their stated load conditions.

Cable lengthInitial contact resistance
1mBelow 150mΩ
2mBelow 200mΩ
5mBelow 350mΩ
Specification referenceStandard
CCC specificationGB/T 14048.5
TUV specificationEN 60947-5-1
CE specification

These standards identify the relevant specification framework; model-specific certification documents are required when certification is part of the purchase specification.

Linear actuator characteristics

Base modelOF max.RF min.PTMDOT max.TT referenceOPDOT min.DOF min.
C6N-P11110N0.5N1.7±0.3mm0.8±0.2mm3mm5mm18±0.5mm4.2mm42.5N
C6N-P12228.5±0.5mm
C6N-P123
C6N-P11733.5±0.5mm
C6N-P12446.5±0.5mm
C6N-P125
C6N-P1157N2.5±0.5mm1.2±0.3mm4.5mm7.5mm35.5±0.5mm6.2mm
C6N-P116

Lever and spring actuator characteristics

Base modelOF max.RF min.PTMDOT max.TT referenceOPDOT min.DOF min.
C6N-P1045N0.5N25±5°12±2°60°90°—70°42.5N
C6N-P105
C6N-P107
C6N-P108
C6N-P109
C6N-P1662N—15±5°10±2°————
C6N-P167
C6N-P168
C6N-P169

OF is operating force; RF is release force; PT is pretravel; MD is movement differential; OT is overtravel; TT is total travel; OP is operating position; DOT and DOF are the travel and force for direct opening. A dash means no value is specified. TT values are references. Linear-head measurements use vertical actuation. P104/P105 use their fixed 26.5mm lever radius; adjustable-head values P107/P108/P109 are measured at a 38.5mm setting. Spring-head values are measured at two-thirds of the head spring with the spring initially unbent.

Mounting and cable connections

Use the two Ø4.2mm mounting holes on 20mm centers with M4 screws and suitable flat and spring washers. Keep the mounting surface rigid and the cam aligned with the selected head. The threaded plunger variants use M12×1 fittings. Refer to the attached drawings for the individual head envelopes and operating positions.

FastenerTightening torque
M4 lever mounting screw1.2–1.4N·m
M4 body mounting screws0.6–0.8N·m

The head can be turned 180° after removing its two screws. Refit it securely and keep particles out of the mechanism. Do not disturb the molded cable outlet. Standard drawings show a Ø6.5mm, 4×0.75mm² cable.

ContactWire pairUnactuated state
NCBK black – BK/WH black/whiteClosed
NOBN brown – BU blueOpen

Make external cable connections with the power isolated. For external M3.5 crimp terminations, use 0.5–0.75mm² conductors, approximately AWG20–AWG18, with insulation sleeves. Keep terminals clear of enclosure edges and keep wire fragments out of the connection enclosure. The following reference dimensions concern external terminations; they do not authorize replacement of the factory cable.

Crimp terminal dimensionValue
Thickness t0.5mm maximum
Stud hole Ødz3.7mm
Barrel ØD2.9mm
Width B6.6mm
Overall length L19mm
Dimension F7.7mm
Dimension l8.0mm
External conductor referenceCable characteristics
CoresConductorOverall diameter
Plastic or rubber insulated flexible cable2, 3 or 40.5–0.75mm²Circular, Ø6–9mm
600V plastic insulated, plastic sheathed cable, VVF2Ø1mm, Ø1.2mm or Ø1.6mm

Cam setting and application limits

Set a cam approach angle below 30°, a surface finish of 6.3S or smoother, and hardness HV400–500. Align the plunger groove with the sleeve top, or place a lever head's arrow between its two setting marks. Cam shape, switching frequency and overtravel affect life and repeatability; do not use the switch as a mechanical stop.

Keep chips, dust and deposits off the actuator. Cutting fluids, solvents and prolonged outdoor exposure can impair seals. Avoid installation where resonance, excessive vibration or impacts can cause unstable switching. Silicone-containing materials can contaminate contacts; avoid silicone oil in adjacent wiring and use suitable suppression where switching produces arcing.

For small loads, maintain at least 24VDC and 10mA. A general-load contact already used for higher loads should not be reassigned to a lower-capacity signal circuit. Below the minimum load, current may not break through surface films; use a contact version specified for the intended signal. Select suitable suppression for contact arcing, noise or inrush.

These are industrial position switches. Applications involving exceptional reliability, personal safety, explosive atmospheres, severe environmental exposure, aerospace or military use require a specifically assessed design. IP67 and NC direct-opening features alone do not establish suitability for those applications.