A-Size Panel Mount Connector Bases

Series Part Number

Part Number: ULO - HC03 - H16A - BK - 1L - MCV
Explanation:

Manufacturer

ULO - ULO Electronics

Housing Series

HC02 - Size 10A; use H10A
HC03 - Size 16A; use H16A
HC04 - Size 32A; use H32A

Housing Size

H10A - Size 10A, HC02, locking code 1L, without cover
H16A - Size 16A, HC03, locking code 1L, with or without cover
H32A - Size 32A, HC04, locking code 2L or 4B; uncovered versions only in this breakdown

Base Type

BK - Panel mounting base; covered options shown here apply to size 16A only

Locking

1L - Single latch, sizes 10A or 16A
2L - Two fitted latches, size 32A
4B - Four studs for a double-latch hood, size 32A

Protective Cover

MCV - Aluminium cover, size 16A only
CV - Polycarbonate cover, size 16A only
Blank - Without protective cover; omit this field and its preceding hyphen

Description

Panel mounting with bottom cable entry

These flanged aluminium bases mount over a panel opening for bottom cable entry. Select the housing size and locking arrangement to suit the insert and mating hood. Housing codes 10A, 16A and 32A describe size families.

PropertySpecification
Base materialDie-cast aluminium
Finish and colourPowder-coated, grey
Temperature range-40°C to +125°C
Ingress protectionIP65 according to IEC60529 for the coupled connector
Cable entryBottom entry through the panel opening
Hood/housing sealingNBR
Fitted latch materialMetal, galvanized/nickel plated

Housing and cover options

Model familyHousing sizeLocking configurationProtective cover
ULO-HC02-H10A-BK-1L10ASingle latchWithout cover
ULO-HC03-H16A-BK-1L16A
ULO-HC03-H16A-BK-1L-XXCV: PC cover; MCV: aluminium cover
ULO-HC04-H32A-BK-2L32ATwo fitted latchesWithout cover
ULO-HC04-H32A-BK-4BFour studs for double locking
ULO-HC04-H32A-BK-4B-XXWith protective cover

For the covered 16A base, select ULO-HC03-H16A-BK-1L-CV or ULO-HC03-H16A-BK-1L-MCV. The 4B bases engage a matching hood fitted with two locking latches.

Panel cutouts and mounting pattern

Housing and configurationPanel openingFour-hole centre patternHole diameterFlange length × widthBody heightOperating clearance and reference dimensions
10A, single latch57mm × 24mm70mm × 17.5mm3.5mm83.5mm × 31.3mm26.5mmLatch swing: 19mm beyond flange edge
16A, single latch without cover73mm × 24mm86mm × 17.5mm98mm × 31.3mm
16A, single latch with coverLatch swing: 19mm; open cover projection: 21.5mm; cover sweep: 58mm beyond the opposite flange edge
32A, two latches73mm × 48mm92mm × 42mm4.4mm104.5mm × 58mm29.5mm68.5mm across latch sides; latch swing: 14mm beyond each flange end
32A, four studs without cover71.5mm across studs, reference dimension
32A, four studs with coverOpen cover projection: 25mm; cover sweep: 85mm beyond flange edge

Body height excludes the raised latch and open cover. Keep the latch and cover swept areas clear when positioning adjacent equipment.

10A panel base outline and panel cutout
10A single-latch base with 57mm × 24mm panel opening and 70mm × 17.5mm hole centres.
16A panel base outline and panel cutout
16A uncovered base with 73mm × 24mm panel opening and 86mm × 17.5mm hole centres.
16A covered panel base dimensions
16A covered base showing the shared CV/MCV mounting pattern and cover operating clearance.
32A double latch panel base dimensions
32A base with two latches: 73mm × 48mm panel opening, four 4.4mm holes and 14mm latch swing beyond each flange end.
32A four stud panel base dimensions
32A four-stud base with 92mm × 42mm hole centres and a 71.5mm reference width across the studs.
32A covered panel base dimensions
Covered 32A four-stud base retaining the same panel opening and mounting pattern, with an 85mm cover sweep.